Anna K. Fritzsche

Anna K. Fritzsche

Auto-generated profile, based on publicly available information

Anna K. Fritzsche

University of Ottawa

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2015 in Mucosal Immunology
Verified
Journal Article
Closed access
PDF file
KSK Schaale
K Schaale
KPK M Peters
K M Peters
AMA M Murthy
A M Murthy
AFA K Fritzsche
A K Fritzsche
MPM-D Phan
M-D Phan
MSMatthew J Sweet
Matthew J Sweet

19 December 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VTVera A. Tang
Vera A. Tang
TRTyler Renner
Tyler Renner
AFAnna K. Fritzsche
Anna K. Fritzsche
DBDylan Burger
Dylan Burger
MLMarc-André Langlois
Marc-André Langlois
Retroviruses and small EVs overlap in size, buoyant densities, refractive indices and share many cell-derived surface markers making them virtually indistinguishable by standard biochemical methods. This poses a significant challenge when purifying retroviruses for downstream analyses or for phenotypic characterization studies of markers on individual virions given that EVs are a major contaminant of retroviral preparations. Nanoscale flow cytometry (NFC), also called flow virometry, is an adaptation of flow cytometry technology for the analysis of individual nanoparticles such as extracellular vesicles (EVs) and retroviruses. In this study we systematically optimized NFC parameters for the detection of retroviral particles in the range of 115–130 nm, including viral production, sample labeling, laser power and voltage settings. By using the retroviral envelope glycoprotein as a selection marker, and evaluating a number of fluorescent dyes and labeling methods, we demonstrate that it is possible to confidently distinguish retroviruses from small EVs by NFC. Our findings make it now possible to individually phenotype genetically modified retroviral particles that express a fluorescent envelope glycoprotein without removing EV contaminants from the sample.

19 April 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
VTVera Tang
Vera Tang
AFAnna K. Fritzsche
Anna K. Fritzsche
TRTyler Renner
Tyler Renner
DBDylan Burger
Dylan Burger
EPEdwin van der Pol
Edwin van der Pol
COChristian V. Ouellet
Christian V. Ouellet
There has been renewed interest in the use of flow cytometry for single particle phenotypic analysis of particles in the nanometer size-range such as viruses, organelles, bacteria and extracellular vesicles (EVs). However, many of these particles are smaller than 200 nm in diameter, which places them at the limit of detection for many commercial flow cytometers. The use of reference particles of diameter, fluorescence, and light-scattering properties akin to those of the small biological particles being studied is therefore imperative for accurate and reproducible data acquisition and reporting across different instruments and analytical technologies. We show here that an engineered murine leukemia virus (MLV) can act as a fluorescence reference particle for other small particles such as retroviruses and EVs. More specifically, we show that engineered MLV is a highly monodisperse enveloped particle that can act as a surrogate to demonstrate the various effects of antibody labeling on the physical properties of small biological particles in a similar diameter range.