Ryo Someya

Ryo Someya

Auto-generated profile, based on publicly available information

Ryo Someya

Graduate School of Frontier Sciences, The University of Tokyo

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2021 in Plasma and Fusion Research
Verified
Journal Article
Open access
PDF file
RSRyo Someya
Ryo Someya
HTHaruaki Tanaka
Haruaki Tanaka
YFYugo Funato
Yugo Funato
YCYunhan Cai
Yunhan Cai
MAMoe Akimitsu
Moe Akimitsu
YOYasushi Ono
Yasushi Ono
We developed a new glass-tube-pair type Doppler probe array for 1D ion velocity vector and temperature measurement. It needs just two parallel glass-tube insertion, realizing low plasma perturbation and 1D ion flow vector measurement on a single discharge. Using four mirrors and optical fibers for one measurement point, this system can measure ion local light emissions of each measurement volume from four different directions, enabling us to measure local ion flow vector and temperature. All set of mirrors and optical fibers are aligned in the two parallel glass tubes for 1D measurement by a single discharge. This system measured successfully ion outflow speed of two merging tokamak plasmas, about 80% of poloidal Alfvén speed in agreement with recent reconnection experiments and theory.

18 May 2026 in Nuclear Fusion
Verified
Journal Article
Open access
HTHiroshi Tanabe
Hiroshi Tanabe
RSRyo Someya
Ryo Someya
TATara Ahmadi
Tara Ahmadi
MGMikhail Gryaznevich
Mikhail Gryaznevich
HWHannah Victoria Willett
Hannah Victoria Willett
YOYasushi Ono
Yasushi Ono
Here we report the latest results on the high-field application of merging/compression (M/C) plasma startup in the ST40 spherical tokamak, using 96-channel 2D ion Doppler tomography and 30-channel Thomson scattering diagnostics installed over the past three years. The new findings and achievements are summarized as follows: (i) the new 96-channel 2D ion Doppler tomography clearly revealed ion heating in the downstream of the reconnection jet and its confinement/transport process. (ii) Electron density also increases in the same region, while electrons are heated around the X-point (or magnetic axis) and electron temperature profile forms a peaked profile. (iii) Quasi-steady sustainment/confinement of M/C startup plasma current and ion temperature has been demonstrated. (iv) Based on a series of M/C experiments, I p ∝ I MC scaling was increased to I p ~ 600kA. (v) Full pressure profile measurement leads to the evaluation of energy conversion ratio of the dissipated magnetic energy of reconnecting field B rec and it was found that ~ 30% of released magnetic energy was converted to ion thermal energy. (vi) The previously demonstrated ΔT i ∝ B rec 2 scaling has successfully been upgraded to ΔU i = 1.5Δ(n e κ B T i ) ∝ B rec 2 for the first time and ΔU i ~ 10kJ/m 3 which was 10 times higher than the previous record in MAST was explored.

1 June 2023 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
RSRyo Someya
Ryo Someya
INItsuki Nakau
Itsuki Nakau
YCYunhan Cai
Yunhan Cai
HTHiroshi Tanabe
Hiroshi Tanabe
YOYasushi Ono
Yasushi Ono
We developed a glass-tube-pair type Doppler probe array for ion velocity distribution function measurement with high spatial and time resolution. By four mirrors and four optical fibers fixed in two parallel glass tubes, the light from ions in each measurement area (3.2 × 2.5 × 1.0 cm3) between tubes is collected in three different directions, and the fibers are led to a Czerny–Turner spectrometer and finally to an ICCD camera (the exposure time of 2 μs) for Doppler spectra measurements with high time resolution. Since the Doppler spectrum profile in each viewing line represents the distribution of the ion velocity component in the line, we can reconstruct 2D velocity distribution by the measured spectra in three viewing lines with tomography techniques. We tested the accuracy of some reconstruction methods from spectra to velocity distribution in numerical simulation and chose the iterative method as the best one. By use of this new diagnostic, we successfully measured the radial profile of ion velocity distribution during magnetic reconnection of merging spherical tokamak plasmas and revealed that their ions have anisotropic velocity distributions.

1 January 2025 in Plasma and Fusion Research
Verified
Journal Article
Open access
PDF file
RSRyo Someya
Ryo Someya
LJLuo Jiaxiao
Luo Jiaxiao
YCYunhan Cai
Yunhan Cai
TATara Ahmadi
Tara Ahmadi
HTHiroshi Tanabe
Hiroshi Tanabe
YOYasushi Ono
Yasushi Ono
The reconnection outflow velocity under high guide field was directly measured using the 1D array of ion Doppler probes and was compared with the E × B, gradient B, and curvature drift velocity calculated from 2D profile measurements of electric and magnetic fields for the first time. It was found that the measured ion velocity profile agrees well with the profile of E × B drift velocity which is much larger than the other drift velocities. The poloidal flux-line velocity is almost equal to the E × B drift and ion flow velocities, probably because magnetic flux is almost frozen into ions due to its large Lundquist number of 102.

16 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
RSRyo Someya
Ryo Someya
HYHibiki Yamazaki
Hibiki Yamazaki
SYSatoru Yajima
Satoru Yajima
TKTakayuki Kobayashi
Takayuki Kobayashi
RIRyosuke Ikeda
Ryosuke Ikeda
KKKen Kajiwara
Ken Kajiwara
Accurate reflectivity data of millimeter wave absorber materials are essential for predicting heat-flux distributions and optimizing the design of dummy loads (DLs) used in electron cyclotron resonance heating (ECRH) systems. However, conventional millimeter wave reflectivity measurements typically exhibit uncertainties of approximately ±5%, which are insufficient for reliable design. In this study, a high-accuracy reflectivity measurement was developed and applied to thermally sprayed TiO2 coatings. Measurements were performed at 110 GHz, corresponding to the operating frequency of the JT-60SA ECRH system. To improve measurement accuracy, an HE11-mode launcher was employed to suppress beam divergence during free-space propagation, and a two-dimensional scanning measurement was performed to capture the full reflected-wave intensity distribution. In addition, a reference-based calibration method using a copper reflector eliminated the need for direct estimation of the incident wave intensity and reduced the influence of source-power fluctuations. Reflectivities were measured for incident angles between 30° and 65° under both S- and P-polarized conditions, achieving an uncertainty of less than ±0.8%. The measured data were successfully approximated using a Fresnel-based model with a single fitting parameter. The resulting reflectivities were implemented in ray-tracing and thermal analyses and validated through comparisons with infrared-camera and calorimetric measurements obtained during 500 kW high-power experiments. Good agreement was obtained for temperature-rise distributions, temporal temperature evolution, and absorbed-power fractions. These results demonstrate that the proposed method provides reliable reflectivity data for predicting heat-flux distributions and power-absorption characteristics and serves as a powerful tool for the design and optimization of low-reflection DLs.