Oscar Geessink

Oscar Geessink

Auto-generated profile, based on publicly available information

Oscar Geessink

Department of Pathology, Radboud University Medical Center, the Netherlands

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
PBPeter Bandi
Peter Bandi
OGOscar Geessink
Oscar Geessink
QMQuirine Manson
Quirine Manson
MDMarcory Van Dijk
Marcory Van Dijk
MBMaschenka Balkenhol
Maschenka Balkenhol
GLGeert Litjens
Geert Litjens
Automated detection of cancer metastases in lymph nodes has the potential to improve assessment of prognosis for patients. To enable fair comparison between the algorithms for this purpose, we set up the CAMELYON17 challenge in conjunction with the IEEE International Symposium on Biomedical Imaging 2017 conference in Melbourne. Over 300 participants registered on the challenge website, of which 23 teams submitted a total of 37 algorithms before the initial deadline. Participants were provided with 899 whole-slide images for developing their algorithms. The developed algorithms were evaluated based on the test set encompassing 100 patients and 500 whole-slide images. The evaluation metric used was a quadratic weighted Cohen’s kappa. We discuss the algorithmic details of the ten best pre-conference and two post-conference submissions. All these participants used convolutional neural networks in combination with pre-and postprocessing steps. Algorithms differed mostly in neural network architecture, training strategy and pre-and postprocessing methodology. Overall, the kappa metric ranged from 0.89 to -0.13 across all submissions. The best results were obtained with pre-trained architectures such as ResNet. Confusion matrix analysis revealed that all participants struggled with reliably identifying isolated tumor cells, the smallest type of metastasis, with detection rates below 40%. Qualitative inspection of the results of the top participants showed categories of false positives, such as nerves or contamination, which could be targets for further optimization. Last, we show that simple combinations of the top algorithms result in higher kappa metric values than any algorithm individually, with 0.93 for the best combination.

1 December 2019 in Medical Image Analysis
Verified
Journal Article
Closed access
ZSZaneta Swiderska-Chadaj
Zaneta Swiderska-Chadaj
HPHans Pinckaers
Hans Pinckaers
MRMart van Rijthoven
Mart van Rijthoven
MBMaschenka Balkenhol
Maschenka Balkenhol
MMMargarita Melnikova
Margarita Melnikova
FCFrancesco Ciompi
Francesco Ciompi