Daniel Henrard

Daniel Henrard

Auto-generated profile, based on publicly available information

Daniel Henrard

Biomedical Physics Unit, Materials Institute, University of Mons, Place du Parc 20, 7000 Mons, Belgium

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2019 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
DHDaniel Henrard
Daniel Henrard
QVQuoc Lam Vuong
Quoc Lam Vuong
SDSébastien Delangre
Sébastien Delangre
XVXavier Valentini
Xavier Valentini
NDNonclercq Denis
Nonclercq Denis
YGYves Gossuin
Yves Gossuin
In this work, aqueous solutions of magnetite nanoparticles (NPs) are studied. Magnetite NPs are very useful in biomedicine for magnetic resonance imaging (MRI), for drug delivery therapy, and also for hyperthermia. In order to predict the NP efficiency in these applications, it is crucial to accurately characterize their size distribution and their magnetization. Magnetometry, through the dependence of NP magnetization on the magnetic induction (MB curve), can provide interesting information on these physical properties. In this work, the extraction of the NP size distribution and magnetization from experimental MB curves of aqueous solutions of magnetite NPs is discussed. The results are compared to TEM and XRD characterizations. It is shown that an expression taking into account the size distribution better fits the results than the commonly used simple Langevin function. The size distributions obtained by magnetometry seem comparable to those obtained by TEM measurements. However, a closer look at the results shows some nonnegligible discrepancies: the size distributions obtained by magnetometry vary with the temperature and are closer to the TEM ones at room temperature. Our study suggests that it could be explained by the nonnegligible anisotropy energy of the NPs at low temperature and the lack of NP Brownian rotation below the freezing point of water. This demonstrates that care must be taken when interpreting the results obtained by magnetometry of magnetite NPs: only the size and size distribution obtained at room temperature should be used.

1 March 2015 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
SDS. Delangre
S. Delangre
QVQ.L. Vuong
Q.L. Vuong
DHD. Henrard
D. Henrard
JMJulie Magat
Julie Magat
CPChrystelle Po
Chrystelle Po
YGY. Gossuin
Y. Gossuin