D. A. Aleksandrova

D. A. Aleksandrova

Auto-generated profile, based on publicly available information

D. A. Aleksandrova

Department of Expertise in Doping and Drug Control Faculty of Chemical and Pharmaceutical Technologies and Biomedical Drugs Mendeleev Russian University of Chemical Technology Moscow 125047 Russia

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2022 in Fine Chemical Technologies
Verified
Journal Article
Open access
PDF file
DAD. A. Aleksandrova
D. A. Aleksandrova
TMT. B. Melamed
T. B. Melamed
EBE. P. Baberkina
E. P. Baberkina
AFA. A. Fenin
A. A. Fenin
EOE. S. Osinova
E. S. Osinova
DZD. I. Zykova
D. I. Zykova
Objectives. To determine the ion mobility of N-methylimidazole, establish the structure of ions corresponding to characteristic signals, and determine the detection limit of N-methylimidazole on the ion-drift detector Kerber.Methods. Ion mobility spectrometry was used to study the ionization processes. The enthalpies of the reactions of monomer and dimer ions were calculated in the ORCA 4.1.1 software by the B3LYP density functional method with a set of basic functions 6-31G (d, p).Results. The drift time and ion mobility values of N-methylimidazole were determined. A method for mathematical processing of spectra and a program for its implementation was developed. The changing peculiarities of the ion mobility spectrum during measurement at a given time were studied. According to the interpretation of the spectrum signals, the structure of the generated ions was proposed, and the enthalpies of ion formation were determined.Conclusions. The characteristic signal of the N-methylimidazole ion protonated at the nitrogen atom of the pyridine type was revealed. It was found that two signals in the ion mobility spectra of N-methylimidazole correspond to the presence of the monomer and dimer ions. The detection limit of N-methylimidazole on the ion-drift detector Kerber was determined, amounting to 3 pg.

7 November 2024 in ChemistrySelect
Verified
Journal Article
Closed access
RKRostislav Kapustin
Rostislav Kapustin
IGIosif Grinvald
Iosif Grinvald
AAAlina Agrba
Alina Agrba
MAMikhail Agrba
Mikhail Agrba
Ilya VorotyntsevIlya Vorotyntsev
Ilya Vorotyntsev
DADaria Aleksandrova
Daria Aleksandrova

4 November 2024 in Fine Chemical Technologies
Verified
Journal Article
Open access
PDF file
DAD. A. Aleksandrova
D. A. Aleksandrova
TMT. B. Melamed
T. B. Melamed
EBE. P. Baberkina
E. P. Baberkina
EOE. S. Osinova
E. S. Osinova
LLL. A. Luzenina
L. A. Luzenina
ASA. G. Sazonov
A. G. Sazonov
Objectives. To determine the ion mobilities of chloroacetophenone, tris(2-chloroethyl)amine, and methanethiol; the structure of ions corresponding to characteristic signals; the detection limits of chloroacetophenone, tris(2-chloroethyl)amine, and methanethiol with the Kerber-T ion drift detector and the Segment automatic stationary gas detector.Methods. Ion mobility spectrometry was used in order to determine the ion mobilities and detect analytes. The enthalpies of reactions of ion formation were calculated using the ORCA 4.1.1 software by means of the B3LYP density functional method with the 6-31G(d,p) basis set.Results. The ion mobilities of chloroacetophenone, tris(2-chloroethyl)amine, and methanethiol were determined. A method for recording ion mobility spectra and their mathematical processing was developed. The dependencies of the change in ion mobility spectra on the analyte concentration were also studied. Possible mechanisms were proposed for the formation of the ion mobility spectra observed, in accordance with the ionization features of chloroacetophenone, tris(2-chloroethyl)amine, and methanethiol. The enthalpies of ion formation were calculated. The ionization schemes of the compounds were shown. The generalized results of experimental studies were presented, as were the features of compound identification taking into account the structure of the spectra, the concentrations of substances, and the detection conditions.Conclusions. Characteristic signals of chloroacetophenone, tris(2-chloroethyl)amine, and methanethiol were identified. All studied hazardous substances can be detected with an ion mobility spectrometer at concentrations at the ppm level. The following detection limits of the substances were determined with the Segment gas detector: chloroacetophenone, 245 mg/m3; tris(2-chloroethyl)amine, 0.01 mg/m3; and methanethiol, 0.8 mg/m3.