22 June 2021 in IEEE Journal of Selected Topics in Quantum Electronics
Miniaturized spectrometers are being developed in the recent few years leveraging the rapidly-progressing technology and triggering new markets in the field of on-site and mobile spectroscopic analysis. Although some devices were commercialized for the near-infrared spectroscopy (NIRS), their size and cost still dont meet the requirements for the ubiquitous deployment of the spectrometer as a spectral sensor needed for the smart industry and IoT applications. In this work we report an integrated microelectromechanical system (MEMS)-based Fourier Transform Infrared (FT-IR) spectral sensor. A monolithic scanning Michelson interferometer MEMS chip and an extended InGaAs photodetector chip are integrated with a micro-optical system in a tiny package with a footprint of 18 mm, presenting the smallest reported FT-IR solution to date. A compact light source head is designed and implemented targeting diffuse-reflection applications. The reported sensors spectral resolution is about 66.6 cm-1 across the spectral range of 1350-2550 nm. The signal-to-noise ratio (SNR) achieved is 8000:1 at 2400 nm in 2 seconds, with an order of magnitude improvement with respect to previously reported fiber-coupled solution. The presented solution provides a low cost, low power, wide wavelength range NIR spectral sensor that can be manufactured with high volumes leveraging economies of scale.
24 February 2016 in Journal of Lightwave Technology
A novel optical MEMS interferometer is proposed based on spatial splitting and combining of optical beams using the imaging properties of multimode interference (MMI) waveguides. The light propagates in air, allowing operation over wide spectral range covering both the infrared and the visible ranges. The optical propagation in the structure is modeled and the interferometer is analyzed by incorporating the modal analysis technique for the waveguides and the angular spectrum approach for free-space propagation. The beam splitter and the overall interferometer are fabricated using deep reactive ion etching technology on silicon-on-insulator wafer. The MMI waveguide sidewalls are aluminum metalized to improve the insertion loss of the interferometer. The fabricated splitter and interferometer are characterized in the visible and near-infrared spectral ranges. The splitter output intensity profile is recorded to verify its wideband proper operation. The interferometer is characterized versus the wavelength and tested as a Fourier transform spectrometer, thanks to a monolithically integrated corner mirror driven by a comb-drive actuator. The spectral resolution obtained is 2.5 nm at 635-nm wavelength.
21 May 2024 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
1 January 2025 in Advanced Devices & Instrumentation
In spectroscopic analysis, the development of cost-effective handheld infrared spectrometers has revolutionized monitoring practices, particularly in industries like agriculture and food production. Analysis time and efficiency of processing the raw spectral data are further boosted by the implementation of machine learning models for identification and quantification purposes. However, the inherent spectral variations arising from the random spatial arrangement of inhomogeneous granular media pose accuracy challenges. To enable real-time monitoring with enhanced precision, a scanning approach is presented herein. It involves the utilization of microelectromechanical systems-based infrared spectral sensors with spot sizes of 3 to 20 mm, facilitating spectrospatial averaging by scanning over the sample surface. A model is developed for the absorbance repeatability of the nonhomogeneous samples. It takes into account the effects of spatial and temporal noise, the sample scanned area, and the optical throughput of the device, also revealing an optimum point for the light spot size. Through experimental validation performed on wheat, chosen among the major cereals, we demonstrate that the spatial scanning method considerably improves absorbance repeatability of the 10-mm sensor by up to 5 times compared to stationary measurements, showing a good agreement with the theoretical model. The impact of sample scanning on artificial intelligence-based chemometrics model accuracy is rigorously assessed using heterogeneous feed samples, revealing remarkable enhancements in the accuracy of prediction models. The 10-mm sensor exhibits a substantial reduction in root mean square error for protein (−60%) and for moisture (−43.5%), 2 major nutritional quality indicators of cereal grains.