17 March 2005 in Physics in Medicine & Biology
MR images are known to be distorted because of both gradient nonlinearity and imperfections in the B0 field, the latter caused either by an imperfect shim or sample-induced distortions. This paper describes in detail a method for correcting the gradient warp distortion, based on a direct field mapping using a custom-built phantom with three orthogonal grids of fluid-filled rods. The key advance of the current work over previous contributions is the large volume of the mapping phantom and the large distortions (>25 mm) corrected, making the method suitable for use with large field of view, extra-cranial images. Experimental measurements on the Siemens AS25 gradient set, as installed on a Siemens Vision scanner, are compared with a theoretical description of the gradient set, based on the manufacturer's spherical harmonic coefficients. It was found that over a volume of 320x200x340 mm3 distortions can be successfully mapped to within the voxel resolution of the raw imaging data, whilst outside this volume, correction is still good but some systematic errors are present. The phenomenon of through-plane distortion (also known as 'slice warp') is examined in detail, and the perturbation it causes to the measurements is quantified and corrected. At the very edges of the region of support provided by the phantom, through-plane distortion is extreme and only partially corrected by the present method. Solutions to this problem are discussed. Both phantom and patient data demonstrate the efficacy of the gradient warp correction.
19 April 2001 in The Journal of Chemical Physics
This letter presents the first direct measurement of the length scale of dynamic heterogeneity in a low molecular weight glass former without the perturbing effect of probe molecules or confinement. Using a multidimensional solid-state exchange NMR experiment, 1 nm heterogeneities were found in glycerol for temperatures ranging from 199 K to 207 K K). This small size and weak temperature dependence allow some distinctions to be made among different models of the glass transition. It is shown that the dynamics are not influenced by a low concentration (0.1 wt. %) relaxation agent
1 January 2007 in American Journal of Roentgenology
OBJECTIVE. The objective of our study was to establish the sensitivity and specificity for prostate cancer detection using a combined 1H MR spectroscopy and diffusion-weighted MRI approach.SUBJECTS AND METHODS. Forty-two men (mean age ± SD, 69.3 ± 4.7 years) with prostate cancer were studied using endorectal T2-weighted imaging, 2D chemical shift imaging (CSI), and isotropic apparent diffusion coefficient (ADC) maps. Regions of interest (ROIs) were drawn around the entire gland, central gland, and peripheral zone tumor, diagnostically defined as low signal intensity on T2-weighted images within a sextant that was biopsy-positive for tumor. Lack of susceptibility artifact on a gradient-echo B0 map through the slice selected for CSI and no high signal intensity on external array T1-weighted images confirmed the absence of significant hemorrhage after biopsy. CSI voxels were classified as nonmalignant or as tumor (ROI included ≥ 30% or 3 70% tumor). Choline-citrate (Cho/Cit) ratios and average ADCs were calc...
1 February 2007 in British Journal of Radiology
The aim of this work was to determine the potential of diffusion weighted magnetic resonance imaging (DW-MRI) for identifying prostate cancer by comparing apparent diffusion coefficients (ADCs) from malignant peripheral zone (PZ) nodules with values from the non-malignant PZ and the predominantly benign central gland (CG). 33 patients with elevated prostate specific antigen (PSA) aged 52-78 years (30 patients with biopsy proven prostate cancer) underwent endorectal MRI with T2 weighted and echo planar diffusion weighting (b = 0 mm2 s(-1), 300 mm2 s(-1), 500 mm2 s(-1) and 800 mm2 s(-1)) sequences. ADCs were measured from 30 malignant PZ nodules (identified on T2 weigting and positive biopsy; median region of interest (ROI) size 41 mm2), 33 CG regions (predominantly benign nodules; median ROI size 218 mm2) and 18 non-malignant PZ regions (ipsilateral biopsies all benign; median ROI size 54.5 mm2). ADCs were (mean+/-standard deviation (SD); mm2 s(-1)): malignant PZ nodules 1.30+/-0.30x10(-3), CG 1.46+/-0.14x10(-3) and non-malignant PZ 1.71+/-0.16x10(-3). Differences between all three groups were statistically significant (p = 0.01 malignant PZ vs CG; p = 0.0001 malignant PZ vs non-malignant PZ and p = 0.0001 CG vs non-malignant PZ). Using receiver operating characteristic curves, cut-off values of 1.39x10(-3) mm2 s(-1) differentiated malignant PZ nodules from predominantly benign CG (sensitivity 60%, specificity 76%) and of 1.6x10(-3) mm2 s(-1) identified malignant from non-malignant PZ (sensitivity 86.7%, specificity 72.2%). These results suggest that DW-MRI has the potential to increase the specificity of prostate cancer detection because ADCs are significantly lower in malignant compared with non-malignant prostate tissue.
1 February 2009 in British Journal of Radiology
Radiotherapy dose escalation improves tumour control in prostate cancer but with increased toxicity. Boosting focal tumour only may allow dose escalation with acceptable toxicity. Intensity-modulated radiotherapy can deliver this, but visualization of the tumour remains limiting. CT or conventional MRI techniques are poor at localizing tumour, but dynamic contrast-enhanced MRI (DCE-MRI) may be superior. 18 patients with prostate cancer had T2 weighted (T2W) and DCE-MRI prior to prostatectomy. The prostate was sectioned meticulously so as to achieve accurate correlation between imaging and pathology. The accuracy of DCE-MRI for cancer detection was calculated by a pixel-by-pixel correlation of quantitative DCE-MRI parameter maps and pathology. In addition, a radiologist interpreted the DCE-MRI and T2W images. The location of tumour on imaging was compared with histology, and the accuracy of DCE-MRI and T2W images was then compared. Pixel-by-pixel comparison of quantitative parameter maps showed a significa...
4 June 2002 in Journal of Non-Crystalline Solids