Tianhao Su

Tianhao Su

Auto-generated profile, based on publicly available information

Tianhao Su

Capital Med Univ, Beijing Friendship Hosp, Dept Intervent Radiol, Beijing, Peoples R China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2020 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
TST. Su
T. Su
PRP. Reymond
P. Reymond
OBO. Brina
O. Brina
PBP. Bouillot
P. Bouillot
PMP. Machi
P. Machi
MVM.I. Vargas
M.I. Vargas
BACKGROUND AND PURPOSE: Flow diverter–induced hemodynamic change plays an important role in the mechanism of intracranial aneurysm occlusion. Our aim was to explore the relationship between aneurysm features and flow-diverter treatment of unruptured sidewall intracranial aneurysms. MATERIALS AND METHODS: MR imaging, 4D phase-contrast, was prospectively performed before flow diverter implantation in each patient with unruptured intracranial aneurysm. Two postprocedure follow-ups were scheduled at 6 and 12 months. Responses were grouped according to whether the aneurysms were occluded or remnant. Preprocedural aneurysm geometries and ostium hemodynamics in 38 patients were compared between the 2 groups at 6 and 12 months. Receiver operating characteristic curve analyses were performed for significant geometric and hemodynamic continuous parameters. RESULTS: After the 6-month assessment, 21 of 41 intracranial aneurysms were occluded, and 9 additional aneurysms were occluded at 12 months. Geometrically, the ostium maximum diameter was significantly larger in the remnant group at 6 and 12 months (both P < .001). Hemodynamically, the proximal inflow zone was more frequently observed in the remnant group at 6 months. Several preprocedural ostium hemodynamic parameters were significantly higher in the remnant group. As a prediction for occlusion, the areas under the curve of the ostium maximum diameter (for 6 and 12 months), systolic inflow rate ratio (for 6 months), and systolic inflow area (for 12 months) reached 0.843, 0.883, 0.855, and 0.860, respectively. CONCLUSIONS: Intracranial aneurysms with a large ostium and strong ostium inflow may need a longer time for occlusion. Preprocedural 4D flow MR imaging can well illustrate ostium hemodynamics and characterize aneurysm treatment responses.

1 May 2023 in Diagnostic and Interventional Radiology
Verified
Journal Article
Open access
SYSiwei Yang
Siwei Yang
ZZZhiyuan Zhang
Zhiyuan Zhang
TSTianhao Su
Tianhao Su
QCQiyang Chen
Qiyang Chen
HWHaochen Wang
Haochen Wang
LJLong Jin
Long Jin
PURPOSE The prognostic role of the tumor volume in patients with hepatocellular carcinoma (HCC) at the Barcelona Clinic Liver Cancer (BCLC) 0 and A stages remains unclear. This study aims to compare the volumetric measurement with linear measurement in early HCC burden profile and clarify the optimal cut-off value of the tumor volume.METHODS The consecutive patients diagnosed with HCC who underwent initial and curative-intent radiofre-quency ablation (RFA) were included retrospectively. The segmentation was performed semi -auto-matically, and enhanced tumor volume (ETV) as well as total tumor volume (TTV) were obtained. The patients were categorized into high-and low-tumor burden groups according to various cut-off values derived from commonly used diameter values, X-tile software, and decision-tree analysis. The inter-and intra-reviewer agreements were measured using the intra-class correlation coeffi-cient. Univariate and multivariate time-to-event Cox regression analyses were performed to identi-fy the prognostic factors of overall survival.RESULTS A total of 73 patients with 81 lesions were analyzed in the whole cohort with a median follow-up of 31.0 (interquartile range: 16.0-36.3). In tumor segmentation, excellent consistency was observed in intra-and inter-reviewer assessments. There was a strong correlation between diameter-derived spherical volume and ETV as well as ETV and TTV. As opposed to all linear candidates and 4,188 mm3 (sphere equivalent to 2 cm in diameter), ETV >14,137 mm3 (sphere equivalent to 3 cm in diameter) or 23,000 mm3 (sphere equivalent to 3.5 cm in diameter) was identified as an independent risk factor of survival. Considering the value of hazard ratio and convenience to use, when ETV was at 23,000 mm3, it was regarded as the optimal volumetric cut-off value in differentiating survival risk.CONCLUSION The volumetric measurement outperforms linear measurement on tumor burden evaluation for survival stratification in patients at BCLC 0 and A stages HCC after RFA.

25 July 2024 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
JYJian-An Yu
Jian-An Yu
SYSi-Wei Yang
Si-Wei Yang
YWYu Wang
Yu Wang
JLJian Li
Jian Li
TSTian-Hao Su
Tian-Hao Su
GCGuang Chen
Guang Chen