Michael Husby

Michael Husby

Auto-generated profile, based on publicly available information

Michael Husby

Research and Development Department, AtaCor Medical, Inc. , 905 Calle Amenecer #360, San Clemente, CA 92673, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2023 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
MBMartin C. Burke
Martin C. Burke
RKReinoud E. Knops
Reinoud E. Knops
VRVivek Reddy
Vivek Reddy
JAJohan Aasbo
Johan Aasbo
MHMichael Husby
Michael Husby
AEAdrian Ebner
Adrian Ebner
BACKGROUND: This study assessed safety and feasibility of a novel extravascular implantable cardioverter defibrillator (ICD) lead when inserted anteriorly through a rib space and connected to various commercially available ICD pulse generators (PGs) placed in either a left mid-axillary or left pectoral pocket. Currently available or investigational, extravascular-ICDs include a subcutaneous or subxiphoid lead connected to customized extravascular-ICD PGs. METHODS: This novel extravascular-ICD (AtaCor Medical Inc, San Clemente, CA) employs a unique intercostal implant technique and is designed to function with commercial DF-4 ICD PGs. In this nonrandomized, single-center, acute study, 36 de novo or replacement ICD (transvenous ICD) patients enrolled to receive a concomitant extravascular-ICD lead inserted through an intercostal space along the left parasternal margin. extravascular-ICD leads were connected to DF-4 compatible ICD PGs positioned in either a left mid-axillary or pectoral pocket for acute sensing and defibrillation testing. Defibrillation testing started at 30 Joules (J) and stepped up or down in 5 to 10 joule increments depending on the success and limitations of the generator used. RESULTS: Successful acute defibrillation using ≤35 J was noted in 100% of left mid-axillary PG subjects (n=27, mean 16.3±8.6 J) and 83% of left pectoral PG subjects (n=6, mean 21.0±8.4 J). Furthermore, 24 of 27 (89%) of patients tested with a left, mid-axillary intermuscular PG had successful VF conversion with defibrillation energies at least 10 J below the maximum delivered output of the device. All evaluable episodes (n=93) were automatically sensed, detected, and shocked. No serious device-related intraoperative adverse events were observed. CONCLUSIONS: This first-in-human study documented the safe and reliable placement of a novel extravascular ICD lead with effective sensing and defibrillation of induced ventricular fibrillation using commercial DF-4 ICD PGs.

3 March 2025 in EP Europace
Verified
Journal Article
Open access
SDShephal K Doshi
Shephal K Doshi
RKReinoud E Knops
Reinoud E Knops
AEAdrian Ebner
Adrian Ebner
MHMichael Husby
Michael Husby
AMAlan Marcovecchio
Alan Marcovecchio
MBMartin C Burke
Martin C Burke
Aims: Intercostal extravascular implantable cardioverter defibrillator (EV-ICD) leads may work better in contact with the pericardium thereby directing pacing and defibrillation energy towards excitable myocytes. We report 3-month safety and performance outcomes with a second-generation intercostal EV-ICD lead paired with standard, commercially available ICD pulse generators (PGs). Methods and results: Subjects undergoing a transvenous ICD (TV-ICD) procedure received a concomitant intercostal EV-ICD lead system. The intercostal EV-ICD lead was connected sequentially to a PG in a left pectoral and then a left mid-axillary location. Extravascular ICD lead assessment included sensing and defibrillation of induced ventricular arrhythmias and pacing capture. The intercostal EV-ICD system was followed in a ‘recording-only’ mode and the control TV-ICD system in ‘therapy delivery’ mode to compare stored events. Devices were evaluated prior to hospital discharge, 2 weeks, 1 month, 2 months, and 3 months post-implant. Defibrillation testing was repeated prior to lead removal; 20/20 (100%) were successfully implanted (median implant time of 9 min). Two major lead complications were reported over a mean of 82 days: (i) lead movement and (ii) infection of both the TV-ICD and EV-ICD systems. Intraoperative pacing capture was achieved with the integrated bipolar configuration in 19 of 20 (95%) subjects. Pacing capture with the EV-ICD system was tolerated in all subjects, with over 90% feeling no pain after a 1-month recovery from the procedure. Induced VF episodes were sensed in all subjects and defibrillated successfully in 17 of 17 patients (100%) with a left mid-axillary PG and 19 of 20 patients (95%) with a left pectoral PG. Sensing and defibrillation were successful in 18 of 18 (100%) tested prior to lead removal. Conclusion: In this pilot experience with a second-generation intercostal EV-ICD lead implantation, sensing and defibrillation of induced VF were successful when paired with a standard ICD PG from either a left mid-axillary or pectoral pocket. Clinical trial registration: NCT number: NCT05791032; URL: https://clinicaltrials.gov/study/NCT05791032

1 August 2018 in European Heart Journal
Verified
Journal Article
Open access
PDF file
AAA Amin
A Amin
MGM R Gold
M R Gold
MBM C Burke
M C Burke
BKB P Knight
B P Knight
SKS J Kalbfleisch
S J Kalbfleisch
SIS-ICD IDE Study Investigators
S-ICD IDE Study Investigators
Background: The Subcutaneous (SQ) Implantable Cardioverter Defibrillator (ICD) requires defibrillation testing at the time of implantation. Predictors of defibrillation success based upon the anterior and posterior position of the pulse generator have been identified through computer modeling.

8 August 2022 in Cardiovascular Revascularization Medicine
Verified
Journal Article
Closed access
GGGary Gershony
Gary Gershony
AEAdrian Ebner
Adrian Ebner
PNPetr Neuzil
Petr Neuzil
VRVivek Reddy
Vivek Reddy
MHMichael P. Husby
Michael P. Husby
MBMartin Burke
Martin Burke

26 February 2023 in medRxiv
Verified
Preprint
Open access
PDF file
MBMartin C. Burke
Martin C. Burke
RKReinoud E. Knops
Reinoud E. Knops
VRVivek Y. Y. Reddy
Vivek Y. Y. Reddy
JAJohan D. Aasbo
Johan D. Aasbo
MHMichael Husby
Michael Husby
AEAdrian Ebner
Adrian Ebner
Structured Objectives: This study assessed safety and feasibility of a novel extravascular (EV) implantable cardioverter-defibrillator (ICD) lead when inserted anteriorly through a rib space and connected to various commercially available ICD pulse generators (PGs) placed in either a left mid-axillary or left pectoral pocket. Background: Currently available or investigational, EV-ICDs include a subcutaneous or subxiphoid lead connected to customized EV-ICD PGs. This novel EV-ICD (AtaCor Medical, Inc, San Clemente, CA) employs a unique intercostal implant technique and is designed to function with commercial DF-4 ICD PGs. Methods: In this non-randomized, single-center, acute study, 36 de novo or replacement transvenous (TV) ICD patients enrolled to receive a concomitant EV-ICD lead inserted through an intercostal space along the left parasternal margin. EV-ICD leads were connected to DF-4 compatible ICD PGs positioned in either a left mid-axillary or pectoral pocket for acute sensing and defibrillation testing. Defibrillation testing started at 30 Joules (J) and stepped down in 10 J increments following conversion success and stepped up in 5 J increments following conversion failure. Results: Successful acute defibrillation using ≤ 35 J was noted in 100% of left mid-axillary PG subjects (n=27, mean 16.3 ± 8.6 J) and 83% of left pectoral PG subjects (n=6, mean 21.0 ± 8.4 J). All evaluable episodes (n=93) were automatically sensed, detected, and shocked. No serious device-related intraoperative adverse events were observed. Conclusions: This first-in-human study documented safe and reliable placement of a novel extravascular ICD lead with effective sensing and defibrillation of induced ventricular fibrillation using commercial DF-4 ICD pulse generators. Condensed This study assessed feasibility of intercostal implantation of a novel extravascular implantable cardioverter-defibrillator (ICD) lead designed to function with commercial DF-4 pulse generators (PGs). Lead placement was successful in 33 of 36 attempts (94%). Acute defibrillation with ≤35 J was successful in 27 of 27 left mid-axillary PG subjects (100%) and 5 of 6 left pectoral PG subjects (83%). All evaluable episodes (n=93) were automatically detected. No serious device-related intraoperative adverse events were observed. This study demonstrates feasibility of a novel extravascular ICD lead with effective sensing and defibrillating of induced ventricular fibrillation using commercial DF-4 PGs.