24 January 2014 in BMC Genomics
Background: A close match of the HLA alleles between donor and recipient is an important prerequisite for successful unrelated hematopoietic stem cell transplantation. To increase the chances of finding an unrelated donor, registries recruit many hundred thousands of volunteers each year. Many registries with limited resources have had to find a trade-off between cost and resolution and extent of typing for newly recruited donors in the past. Therefore, we have taken advantage of recent improvements in NGS to develop a workflow for low-cost, high-resolution HLA typing. Results: We have established a straightforward three-step workflow for high-throughput HLA typing: Exons 2 and 3 of HLA-A, -B, -C, -DRB1, -DQB1 and -DPB1 are amplified by PCR on Fluidigm Access Array microfluidic chips. Illumina sequencing adapters and sample specific tags are directly incorporated during PCR. Upon pooling and cleanup, 384 samples are sequenced in a single Illumina MiSeq run. We developed “neXtype” for streamlined data analysis and HLA allele assignment. The workflow was validated with 1140 samples typed at 6 loci. All neXtype results were concordant with the Sanger sequences, demonstrating error-free typing of more than 6000 HLA loci. Current capacity in routine operation is 12,000 samples per week. Conclusions: The workflow presented proved to be a cost-efficient alternative to Sanger sequencing for high-throughput HLA typing. Despite the focus on cost efficiency, resolution exceeds the current standards of Sanger typing for donor registration.
14 February 2017 in BMC Genomics
At the DKMS Life Science Lab, Next Generation Sequencing (NGS) has been used for ultra-high-volume high-resolution genotyping of HLA loci for the last three and a half years. Here, we report on our experiences in genotyping the HLA, CCR5, ABO, RHD and KIR genes using a direct amplicon sequencing approach on Illumina MiSeq and HiSeq 2500 instruments. Between January 2013 and June 2016, 2,714,110 samples largely from German, Polish and UK-based potential stem cell donors have been processed. 98.9% of all alleles for the targeted HLA loci (HLA-A, -B, -C, -DRB1, -DQB1 and -DPB1) were typed at high resolution or better. Initially a simple three-step workflow based on nanofluidic chips in conjunction with 4-primer amplicon tagging was used. Over time, we found that this setup results in PCR artefacts such as primer dimers and PCR-mediated recombination, which may necessitate repeat typing. Split workflows for low- and high-DNA-concentration samples helped alleviate these problems and reduced average per-locus repeat rates from 3.1 to 1.3%. Further optimisations of the workflow included the use of phosphorothioate oligos to reduce primer degradation and primer dimer formation, and employing statistical models to predict read yield from initial template DNA concentration to avoid intermediate quantification of PCR products. Finally, despite the populations typed at DKMS Life Science Lab being relatively homogenous genetically, an analysis of 1.4 million donors processed between January 2015 and May 2016 led to the discovery of 1,919 distinct novel HLA alleles. Amplicon-based NGS HLA genotyping workflows have become the workhorse in high-volume tissue typing of registry donors. The optimisation of workflow practices over multiple years has led to insights and solutions that improve the efficiency and robustness of short amplicon based genotyping workflows.
20 May 2016 in BMC Genomics
The characterization of the ABO blood group status is vital for blood transfusion and solid organ transplantation. Several methods for the molecular characterization of the ABO gene, which encodes the alleles that give rise to the different ABO blood groups, have been described. However, the application of those methods has so far been restricted to selected samples and not been applied to population-scale analysis. We describe a cost-effective method for high-throughput genotyping of the ABO system by next generation sequencing. Sample specific barcodes and sequencing adaptors are introduced during PCR, rendering the products suitable for direct sequencing on Illumina MiSeq or HiSeq instruments. Complete sequence coverage of exons 6 and 7 enables molecular discrimination of the ABO subgroups and many alleles. The workflow was applied to ABO genotype more than a million samples. We report the allele group frequencies calculated on a subset of more than 110,000 sampled individuals of German origin. Further we discuss the potential of the workflow for high resolution genotyping taking the observed allele group frequencies into account. Finally, sequence analysis revealed 287 distinct so far not described alleles of which the most abundant one was identified in 174 samples. The described workflow delivers high resolution ABO genotyping at low cost enabling population-scale molecular ABO characterization.
30 May 2017 in BMC Bioinformatics
Knowledge of HLA haplotypes is helpful in many settings as disease association studies, population genetics, or hematopoietic stem cell transplantation. Regarding the recruitment of unrelated hematopoietic stem cell donors, HLA haplotype frequencies of specific populations are used to optimize both donor searches for individual patients and strategic donor registry planning. However, the estimation of haplotype frequencies from HLA genotyping data is challenged by the large amount of genotype data, the complex HLA nomenclature, and the heterogeneous and ambiguous nature of typing records. To meet these challenges, we have developed the open-source software Hapl-o-Mat. It estimates haplotype frequencies from population data including an arbitrary number of loci using an expectation-maximization algorithm. Its key features are the processing of different HLA typing resolutions within a given population sample and the handling of ambiguities recorded via multiple allele codes or genotype list strings. Implemented in C++, Hapl-o-Mat facilitates efficient haplotype frequency estimation from large amounts of genotype data. We demonstrate its accuracy and performance on the basis of artificial and real genotype data. Hapl-o-Mat is a versatile and efficient software for HLA haplotype frequency estimation. Its capability of processing various forms of HLA genotype data allows for a straightforward haplotype frequency estimation from typing records usually found in stem cell donor registries.
30 January 2014 in PLOS ONE
Population-specific matching probabilities (MP) are a key parameter to assess the benefits of unrelated stem cell donor registries and the need for further donor recruitment efforts. In this study, we describe a general framework for MP estimations of specific and mixed patient populations under consideration of international stem cell donor exchange. Calculations were based on population-specific 4-locus (HLA-A, -B, -C, -DRB1) high-resolution haplotype frequencies (HF) of up to 21 populations. In various scenarios, we calculated several quantities of high practical relevance, including the maximal MP that can be reached by recruiting a fixed number of donors, the corresponding optimal composition by population of new registrants, and the minimal number of donors who need to be recruited to reach a defined MP. Starting at current donor numbers, the largest MP increases due to n = 500,000 additional same-population donors were observed for patients from Bosnia-Herzegovina (+0.25), Greece (+0.21) and Romania (+0.20). Especially small MP increases occurred for European Americans (+0.004), Germans (+0.01) and Hispanic Americans (+0.01). Due to the large Chinese population, the optimal distribution of n = 5,000,000 new donors worldwide included 3.9 million Chinese donors. As a general result of our calculations, we observed a need for same-population donor recruitment in order to increase population-specific MP efficiently. This result was robust despite limitations of our input data, including the use of HF derived from relatively small samples ranging from n = 1028 (Bosnia-Herzegovina) to n = 33,083 (Turkey) individuals. National strategies that neglect domestic donor recruitment should therefore be critically re-assessed, especially if only few donors have been recruited so far.