Arjan W. Rauwers

Arjan W. Rauwers

Auto-generated profile, based on publicly available information

Arjan W. Rauwers

Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2018 in Gut
Verified
Journal Article
Open access
PDF file
ARArjan W Rauwers
Arjan W Rauwers
AHAnne F Voor In ’T Holt
Anne F Voor In ’T Holt
JBJolanda G Buijs
Jolanda G Buijs
WGWoutrinus de Groot
Woutrinus de Groot
BHBettina Hansen
Bettina Hansen
MVMargreet C Vos
Margreet C Vos
Objective: Increasing numbers of outbreaks caused by contaminated duodenoscopes used for Endoscopic Retrograde Cholangiopancreatography (ERCP) procedures have been reported, some with fatal outcomes. We conducted a nationwide cross-sectional study to determine the prevalence of bacterial contamination of reprocessed duodenoscopes in The Netherlands. Design: All 73 Dutch ERCP centres were invited to sample ≥2 duodenoscopes using centrally distributed kits according to uniform sampling methods, explained by video instructions. Depending on duodenoscope type, four to six sites were sampled and centrally cultured. Contamination was defined as (1) any microorganism with ≥20 colony forming units (CFU)/20 mL (AM20) and (2) presence of microorganisms with gastrointestinal or oral origin, independent of CFU count (MGO). Results: Sixty-seven out of 73 centres (92%) sampled 745 sites of 155 duodenoscopes. Ten different duodenoscope types from three distinct manufacturers were sampled including 69 (46%) Olympus TJF-Q180V, 43 (29%) Olympus TJF-160VR, 11 (7%) Pentax ED34-i10T, 8 (5%) Pentax ED-3490TK and 5 (3%) Fujifilm ED-530XT8. Thirty-three (22%) duodenoscopes from 26 (39%) centres were contaminated (AM20). On 23 (15%) duodenoscopes MGO were detected, including Enterobacter cloacae, Escherichia coli, Klebsiella pneumonia and yeasts. For both definitions, contamination was not duodenoscope type dependent (p values: 0.20 and higher). Conclusion: In 39% of all Dutch ERCP centres, at least one AM20-contaminated patient-ready duodenoscope was identified. Fifteen per cent of the duodenoscopes harboured MGO, indicating residual organic material of previous patients, that is, failing of disinfection. These results suggest that the present reprocessing and process control procedures are not adequate and safe.

1 November 2019 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
ARArjan W. Rauwers
Arjan W. Rauwers
ATAnnet Troelstra
Annet Troelstra
AFAd C. Fluit
Ad C. Fluit
CWCamiel Wissink
Camiel Wissink
ALArjo J. Loeve
Arjo J. Loeve
JMJan F. Monkelbaan
Jan F. Monkelbaan

1 September 2020 in Gastrointestinal Endoscopy
Verified
Journal Article
Open access
ARArjan W. Rauwers
Arjan W. Rauwers
AHAnne F. Voor In ‘T Holt
Anne F. Voor In ‘T Holt
JBJolanda G. Buijs
Jolanda G. Buijs
WGWoutrinus de Groot
Woutrinus de Groot
NENicole S. Erler
Nicole S. Erler
MVMargreet C. Vos
Margreet C. Vos
Contaminated duodenoscopes and linear echoendoscopes (DLEs) pose a risk for infectious outbreaks. To identify DLE and reprocessing risk factors, we combined the data of the previously published nationwide cross-sectional PROCESS 1 study (Prevalence of contamination of complex endoscopes in the Netherlands) with the follow-up PROCESS 2 study. We invited all 74 Dutch DLE centers to sample ≥2 duodenoscopes during PROCESS 1, and all duodenoscopes as well as linear echoendoscopes during PROCESS 2. The studies took place one year after another. Local staff sampled of each DLE ≤6 sites according to uniform methods explained by online videos. We used 2 contamination definitions: (1) any microorganism with ≥20 colony-forming units (CFU)/20 mL (AM20) and (2) presence of microorganisms with gastrointestinal or oral origin, independent of CFU count (MGO). We assessed the factors age and usage by performing an analysis of pooled data of both PROCESS studies; additional factors including reprocessing characteristics were only recorded in PROCESS 2. Of all Dutch centers 97% (72/74; PROCESS 1: 66, PROCESS 2: 61) participated in one of the studies, sampling 309 duodenoscopes and 64 linear echoendoscopes. In total 54 (17%) duodenoscopes and 8 (13%) linear echoendoscopes were contaminated according to the AM20 definition. MGO were detected on 47 (15%) duodenoscopes and 9 (14%) linear echoendoscopes. Contamination was not age or usage dependent (all P values ≥0.27), and not shown to differ between the reprocessing characteristics (all P values ≥0.01). In these nationwide studies, we found that DLE contamination was independent of age and usage. These results suggest that old and heavily used DLEs, if maintained correctly, have a similar risk for contamination as brand-new DLEs. The MGO contamination prevalence of ∼15% was similarly high for duodenoscopes as for linear echoendoscopes; rendering both patients undergoing endoscopic retrograde cholangiopancreatography as well as endoscopic ultrasound at risk for transmission of microorganisms.

1 October 2019 in Techniques in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
ARArjan W. Rauwers
Arjan W. Rauwers
JKJudith A. Kwakman
Judith A. Kwakman
MVMargreet C. Vos
Margreet C. Vos
MBMarco. J. Bruno
Marco. J. Bruno

24 March 2022 in Gastrointestinal Endoscopy
Verified
Journal Article
Open access
ARArjan W. Rauwers
Arjan W. Rauwers
AHAnne F. Voor In ‘t Holt
Anne F. Voor In ‘t Holt
JBJolanda G. Buijs
Jolanda G. Buijs
WGWoutrinus de Groot
Woutrinus de Groot
NENicole S. Erler
Nicole S. Erler
MBMarco J. Bruno
Marco J. Bruno
We investigated whether the use of postmanual cleaning adenosine triphosphate (ATP) tests lowers the number of duodenoscopes and linear echoendoscopes (DLEs) contaminated with gut flora. In this single-center before-and-after study, DLEs were ATP tested after cleaning. During the control period, participants were blinded to ATP results: ATP-positive DLEs were not recleaned. During the intervention period, ATP-positive DLEs were recleaned. DLEs underwent microbiologic sampling after high-level disinfection (HLD) with participants blinded to culture results. Using 15 endoscopes of 5 different DLE types, we included 909 procedures (52% duodenoscopes, 48% linear echoendoscopes). During the intervention period, the absolute rate of contamination with gut flora was higher (16% vs 21%). The main analysis showed that contamination was less likely to occur in the intervention period (odds ratio, .32; 95% credible interval [CI], .12-.85). A secondary analysis showed that this effect was based on 1 particular duodenoscope type (estimated probability, 39% [95% CI, 18%-64%] vs 9% [95% CI, 2%-21%]), whereas no effect was seen in the other 4 DLE types. In detail, of the 4 duodenoscopes of this type, 2 had lower contamination rates (69% vs 39% and 36% vs 10%). During the control period, both these duodenoscopes had multiple episodes with ongoing contamination with the same microorganism that ended weeks before the start of the intervention period (ie, they were not terminated by ATP testing). Postmanual cleaning ATP tests do not reduce post-HLD gut flora contamination rates of DLEs. Hence, postcleaning ATP tests are not suited as a means for quality control of endoscope reprocessing.

1 May 2016 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
ARArjan W. Rauwers
Arjan W. Rauwers
AHAnne F. Voor In 'T Holt
Anne F. Voor In 'T Holt
RGRon De Groot
Ron De Groot
JBJolanda G. Buijs
Jolanda G. Buijs
MVMargreet C. Vos
Margreet C. Vos
Marco BrunoMarco Bruno
Marco Bruno