Bernhard Voss

Bernhard Voss

Auto-generated profile, based on publicly available information

Bernhard Voss

Department of Cardiovascular Surgery, TUM University Hospital German Heart Center, Technical University Munich, Lazarettstrasse 36, 80636 Munich, Germany

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2008 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
BVBernhard Voss
Bernhard Voss
RBRobert Bauernschmitt
Robert Bauernschmitt
AWAlbrecht Will
Albrecht Will
MKMarkus Krane
Markus Krane
RKRuth Kröss
Ruth Kröss
RLRüdiger Lange
Rüdiger Lange
Sternal dehiscence after median sternotomy can be a challenging problem in case of multiple fractures or infection. The use of titanium plates is a promising approach for sternal reconstruction. Titanium plate fixation was used in 15 patients (67+/-5.9 years, 171+/-8.2 cm, 93.6+/-14.9 kg, body mass index 32+/-5 kg/m(2)) with unstable thorax after failed attempts of sternal closure and patients in whom failure of conventional rewiring would be expected due to one or more serious risk factors (e.g. multiple fractures or loss of sternum, excessive overweight). In six patients, one of whom had an infection, the Synthes Titanium Sternal Fixation System was used as transverse plate fixation (series 1). In nine other patients, longitudinal titanium plating of the sternum was performed with 2.4mm Synthes locking reconstruction plates, which were cross-connected by wires (series 2). In six of these patients the cross-connection was reinforced by additional short transverse plates. In series 2, sternal instability was complicated by multiple fragments of sternum (n=8) and/or infection (n=3). In case of infection, initial debridement was performed with consecutive antibiotic and topical negative pressure therapy (median 13 days). Clinical examination was done 3-12 months postoperatively. Mean operation time was 133+/-21 min (series 1) and 110+/-12 min (series 2). Transverse plating required more extensive mobilization of pectoral muscle. All patients had an uneventful early postoperative course and were extubated 5.1+/-5.9h (median 4 h) after surgery. Postoperatively, all patients had a stable thorax, but in the long-term three patients from series 1 complained of plate-related pain during breathing, with the subsequent need of plate removal. One multi morbid patient from series 1 died on the 31st postoperative day. The cause of death was not related to the sternal plate refixation. Titanium plate fixation is an effective method to stabilize complicated sternal dehiscence. The longitudinal plating technique is easier to apply and seems to be associated with fewer complications.

1 January 2010 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
BVBernhard Voss
Bernhard Voss
MKMarkus Krane
Markus Krane
CJChristoph Jung
Christoph Jung
GBGernot Brockmann
Gernot Brockmann
SBSiegmund Braun
Siegmund Braun
RBRobert Bauernschmitt
Robert Bauernschmitt
Advocates of pulsatile flow postulate that the flow pattern during extracorporeal circulation (ECC) should be similar to the physiological one. However, the waveforms generated by clinically used pulsatile pumps are by far different from the physiological ones. Therefore, we constructed a new computer-controlled pulsator which can provide nearly physiological perfusion patterns during ECC. We compared its effect (group 1) with pulsatile (group 2) and non-pulsatile (group 3) perfusion generated by a conventional roller pump. Thirty pigs (10 per group) underwent 180 min ECC with an aortic cross-clamp time of 120 min. Pulse pressure, peak aortic flow, dp/dt(max), pulsatility index and energy-equivalent pressure were measured online. Renal and intestinal blood flow was calculated by fluorescent microspheres. The inflammatory response was assessed by the level of interleukin 6/1ra, the haemolysis by the free haemoglobin, and the escape rate of plasma protein by the disappearance rate of Evans Blue dye. When compared to the preoperative curves, pulsatile waveforms during ECC were similar in group 1 and severely damped in group 2. Inflammatory response increased without significant differences between the groups. There were no differences between groups in renal and bowel blood flow. Free haemoglobin after ECC was higher in the pulsatile groups (group 1=43+/-144 mg dl(-1), group 2=40+/-164 mg dl(-1), group 3=11+/-4mgdl(-1); group 1 vs 2 (ns); group 1 or 2 vs 3 (p<0.001)). The escape rate of Evans Blue increased after ECC in group 1 1.8-fold (p<0.05), in group 2 1.45-fold (p<0.05) and in group 3 1.27-fold (ns). Even when using pulsatile flow patterns which mimic closely the physiological waveforms, there is no advantage concerning organ perfusion or inflammatory response. Moreover, the extent of haemolysis and capillary leak is higher compared to non-pulsatile perfusion. Efforts to optimise pulsatility are not justified.

1 January 2011 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
SDSara Dummler
Sara Dummler
SEStefan Eichhorn
Stefan Eichhorn
CTChristian Tesche
Christian Tesche
USUlrich Schreiber
Ulrich Schreiber
BVBernhard Voss
Bernhard Voss
Markus KraneMarkus Krane
Markus Krane
The use of human saphenous vein grafts (HSVGs) as a bypass conduit is a standard procedure in the treatment of coronary artery disease while their early occlusion remains a major problem. We have developed an ex vivo perfusion system, which uses standardized and strictly controlled hemodynamic parameters for the pulsatile and non-static perfusion of HSVGs to guarantee a reliable analysis of molecular parameters under different pressure conditions. Cell viability of HSVGs (n = 12) was determined by the metabolic conversion of 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide (MTT) into a purple formazan dye. Under physiological flow rates (10 mmHg) HSVGs remained viable for two weeks. Their exposure to arterial conditions (100 mmHg) was possible for one week without important reduction in viability. Baseline expression of matrix metalloproteinase-2 (MMP-2) after venous perfusion (2.2 ± 0.5, n = 5) was strongly up-regulated after exposure to arterial conditions for three days (19.8 ± 4.3) or five days (23.9 ± 6.1, p < 0.05). Zymographic analyses confirmed this increase on the protein level. Our results suggest that expression and activity of MMP-2 are strongly increased after exposure of HSVGs to arterial hemodynamic conditions compared to physiological conditions. Therefore, our system might be helpful to more precisely understand the molecular mechanisms leading to an early failure of HSVGs.

1 August 2007 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
BVBernhard Voss
Bernhard Voss
RBRobert Bauernschmitt
Robert Bauernschmitt
GBGernot Brockmann
Gernot Brockmann
RLRüdiger Lange
Rüdiger Lange
We present a case of a 66-year-old diabetic patient with chronic non-healing sternum after CABG operation. After four attempts of sternum refixation within 2 years, the need of bone debridement resulted in a nearly complete loss of sternum. Finally, a mesh graft and a pectoralis muscle flap were used to bridge the sternal space. Despite good wound healing, the thoracic instability led to intolerable chest pain persisting over the next years. In this case report, we describe the successful thoracic stabilization by using transverse plate fixation, which resulted in perfect thoracic stabilization and immediate cessation of pain.

1 May 2002 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
BVB Voss
B Voss
The Fontan circulation is a direct connection between the systemic veins and the pulmonary artery (PA). Consequently, the pulmonary flow is passive due to the gradient between the right and left atrial pressure. In patients with increased pulmonary vascular resistance, the surgical procedure of atrio-pulmonary connection is therefore prone to failure. The goal of this experiment was to increase the pulmonary flow in an experimental model of a Fontan circulation by performing a right atrial cardiomyoplasty (ACMP). In 19 Foxhounds the left m. latissimus dorsi (LD) was mobilised and transferred as a pedicle into the chest. After sternotomy a 'Fontan circulation' was created under cardiopulmonary bypass (CPB) by connecting the right atrium (RA) with the PA by a valveless conduit. The tricuspid valve was closed with a patch. In 11 dogs (group 1) a valve was implanted in the inferior vena cava (IVC) and pulmonary inflow impedance was increased by partial occlusion of the conduit to a gradient of 10 mmHg between RA and PA. In the other eight dogs (group 2) no valve was implanted, but flowmeters were placed in the IVC and the superior vena cava (SVC). In all dogs the RA was enlarged by a fascia lata patch before the LD was wrapped over the RA and stimulated synchronously to the R-wave with burst impulses. After coming off CPB, relatively high central venous pressures (22.5+/-5.8 mmHg) were necessary to maintain haemodynamic stability. With LD-stimulation in a 1:3 mode in group 1, RA pressure (P) increased from 23.1+/-7.7 to 45+/-10.5 mmHg (P<0.001), pulmonary atrial pressure (PAP) from 15.5+/-4.3 to 25.5+/-7.6 mmHg (P<0.001) and central venous pressure increased to 33.1+/-11.3 mmHg (P<0.05). Stroke volume increase from 11.4+/-4.7 to 17.2+/-4.3 ml and peak conduit-flow from 1286.3+/-880.3 to 2329+/-1173 ml/min (all P<0.001). In a 1:1 stimulation mode a pulsatile pressure/flow profile was obtained in the PA-conduit. Furthermore, at higher frequencies of about 120 beats/min muscle relaxation was still fast enough as not to interfere with the RA filling. In group 2 caval flow without stimulation occurred mainly during diastole. However, with LD-stimulation, a strong backflow into IVC and SVC was observed resulting in a less pronounced pressure/flow increase in the PA. Our experimental model demonstrates the possibility of a 'ventricularisation' of the RA by using the force of the LD. However, the haemodynamic benefit of ACMP was achieved only, when a valve was implanted in the ICV.