Ali Kazemi Jahromi

Ali Kazemi Jahromi

Auto-generated profile, based on publicly available information

Ali Kazemi Jahromi

Department of Electrical Engineering, California Institute of Technology 1 , Pasadena, California 91125, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in APL Photonics
Verified
Journal Article
Open access
PDF file
JXJian Xu
Jian Xu
AJAli K. Jahromi
Ali K. Jahromi
JBJoshua Brake
Joshua Brake
JRJ. Elliott Robinson
J. Elliott Robinson
CYChanghuei Yang
Changhuei Yang
Infrared light scattering methods have been developed and employed to non-invasively monitor human cerebral blood flow (CBF). However, the number of reflected photons that interact with the brain is low when detecting blood flow in deep tissue. To tackle this photon-starved problem, we present and demonstrate the idea of interferometric speckle visibility spectroscopy (ISVS). In ISVS, an interferometric detection scheme is used to boost the weak signal light. The blood flow dynamics are inferred from the speckle statistics of a single frame speckle pattern. We experimentally demonstrated the improvement in the measurement of fidelity by introducing interferometric detection when the signal photon number is low. We apply the ISVS system to monitor the human CBF in situations where the light intensity is ∼100-fold less than that in common diffuse correlation spectroscopy (DCS) implementations. Due to the large number of pixels (∼2 × 105) used to capture light in the ISVS system, we are able to collect a similar number of photons within one exposure time as in normal DCS implementations. Our system operates at a sampling rate of 100 Hz. At the exposure time of 2 ms, the average signal photoelectron number is ∼0.95 count/pixel, yielding a single pixel interferometric measurement signal-to-noise ratio (SNR) of ∼0.97. The total ∼2 × 105 pixels provide an expected overall SNR of 436. We successfully demonstrate that the ISVS system is able to monitor the human brain pulsatile blood flow, as well as the blood flow change when a human subject is doing a breath-holding task.

1 January 2021 in APL Photonics
Verified
Journal Article
Open access
PDF file
JXJian Xu
Jian Xu
AJAli K Jahromi
Ali K Jahromi
CYChanghuei Yang
Changhuei Yang
Diffusing wave spectroscopy (DWS) is a well-known set of methods to measure the temporal dynamics of dynamic samples. In DWS, dynamic samples scatter the incident coherent light, and the information of the temporal dynamics is encoded in the scattered light. To record and analyze the light signal, there exist two types of methods—temporal sampling methods and speckle ensemble methods. Temporal sampling methods, including diffuse correlation spectroscopy, use one or multiple large bandwidth detectors to sample well and analyze the temporal light signal to infer the sample temporal dynamics. Speckle ensemble methods, including speckle visibility spectroscopy, use a high-pixel-count camera sensor to capture a speckle pattern and use the speckle contrast to infer sample temporal dynamics. In this paper, we theoretically and experimentally demonstrate that the decorrelation time (τ) measurement accuracy or signal-to-noise ratio (SNR) of the two types of methods has a unified and similar fundamental expression based on the number of independent observables (NIO) and the photon flux. Given a time measurement duration, the NIO in temporal sampling methods is constrained by the measurement duration, while speckle ensemble methods can outperform by using simultaneous sampling channels to scale up the NIO significantly. In the case of optical brain monitoring, the interplay of these factors favors speckle ensemble methods. We illustrate that this important engineering consideration is consistent with the previous research on blood pulsatile flow measurements, where a speckle ensemble method operating at 100-fold lower photon flux than a conventional temporal sampling system can achieve a comparable SNR.

7 November 2017 in Nature Communications
Verified
Journal Article
Open access
PDF file
AJAli K. Jahromi
Ali K. Jahromi
AHAbsar U. Hassan
Absar U. Hassan
DCDemetrios N. Christodoulides
Demetrios N. Christodoulides
AAAyman Abouraddy
Ayman Abouraddy
Parity-time (PT)-symmetry in optics is a condition whereby the real and imaginary parts of the refractive index across a photonic structure are deliberately balanced. This balance can lead to interesting optical phenomena, such as unidirectional invisibility, loss-induced lasing, single-mode lasing from multimode resonators, and non-reciprocal effects in conjunction with nonlinearities. Because PT-symmetry has been thought of as fragile, experimental realisations to date have been usually restricted to on-chip micro-devices. Here, we demonstrate that certain features of PT-symmetry are sufficiently robust to survive the statistical fluctuations associated with a macroscopic optical cavity. We examine the lasing dynamics in optical fibre-based coupled cavities more than a kilometre in length with balanced gain and loss. Although fluctuations can detune the cavity by more than the free spectral range, the behaviour of the lasing threshold and the laser power is that expected from a PT-stable system. Furthermore, we observe a statistical symmetry breaking upon varying the cavity loss.

19 March 2019 in Optics Letters
Verified
Journal Article
Open access
PDF file
SSSoroush Shabahang
Soroush Shabahang
AJAli K. Jahromi
Ali K. Jahromi
ASAbbas Shiri
Abbas Shiri
Kenneth L ScheplerKenneth L Schepler
Kenneth L Schepler
AAAyman Abouraddy
Ayman Abouraddy
While passive illumination schemes often utilize a broadband spectral acceptance, the performance of active illumination with a laser is improved by narrowband spectral filtering at the sensor. We present an experimental demonstration of an optical cavity structure that is capable of toggling between two performance limits: narrowband resonant and broadband omni-resonant transmission. To achieve omni-resonance without modifying the cavity, the incident optical field is pre-conditioned by associating each wavelength with a particular incidence angle that enables a broad continuous spectrum to resonate with the cavity. This strategy can help seamlessly combine passive and active illumination in the same system.

27 March 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LMLane Martin
Lane Martin
DMDavood Mardani
Davood Mardani
HKH. Esat Kondakci
H. Esat Kondakci
WLWalker D. Larson
Walker D. Larson
SSSoroush Shabahang
Soroush Shabahang
AAAyman Abouraddy
Ayman Abouraddy
Interferometry is one of the central organizing principles of optics. Key to interferometry is the concept of optical delay, which facilitates spectral analysis in terms of time-harmonics. In contrast, when analyzing a beam in a Hilbert space spanned by spatial modes – a critical task for spatial-mode multiplexing and quantum communication – basis-specific principles are invoked that are altogether distinct from that of ‘delay’. Here, we extend the traditional concept of temporal delay to the spatial domain, thereby enabling the analysis of a beam in an arbitrary spatial-mode basis – exemplified using Hermite-Gaussian and radial Laguerre-Gaussian modes. Such generalized delays correspond to optical implementations of fractional transforms; for example, the fractional Hankel transform is the generalized delay associated with the space of Laguerre-Gaussian modes, and an interferometer incorporating such a ‘delay’ obtains modal weights in the associated Hilbert space. By implementing an inherently stable, reconfigurable spatial-light-modulator-based polarization-interferometer, we have constructed a ‘Hilbert-space analyzer’ capable of projecting optical beams onto any modal basis.

24 October 2016 in Optica
Verified
Journal Article
Open access
PDF file
AJAli K. Jahromi
Ali K. Jahromi
AAAyman Abouraddy
Ayman Abouraddy
Optical power flow along an active cavity having net gain can differ dramatically from that in a passive cavity. We report the first observation of Poynting’s vector reversal in an active cavity under scattering boundary conditions. At a sub-lasing gain, which we call Poynting’s threshold, a null develops in Poynting’s vector, which divides the cavity into sections with oppositely directed energy flows. Furthermore, we demonstrate that the direction of Poynting’s vector at a fixed point in an active cavity can be controllably reversed without changing its magnitude via an intra-cavity passive element, thereby suggesting a potential methodology for optical switching.