Peter Kjær Willendrup

Peter Kjær Willendrup

Auto-generated profile, based on publicly available information

Peter Kjær Willendrup

Data Management and Scientific Computing, European Spallation Source ERIC, Kongens Lyngby, Denmark

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2011 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
LUL. Udby
L. Udby
PWP.K. Willendrup
P.K. Willendrup
EKErik Bergbäck Knudsen
Erik Bergbäck Knudsen
CNCh. Niedermayer
Ch. Niedermayer
UFU. Filges
U. Filges
Kim LefmannKim Lefmann
Kim Lefmann

1 April 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
RTRasmus Toft-Petersen
Rasmus Toft-Petersen
GTGregory S. Tucker
Gregory S. Tucker
LWLiam Whitelegg
Liam Whitelegg
KKKristine Marie Løfgren Krighaar
Kristine Marie Løfgren Krighaar
TGTamires Gallo
Tamires Gallo
NCNiels Bech Christensen
Niels Bech Christensen
We present the detailed design and performance simulations of BIFROST, a multiplexing indirect neutron time-of-flight spectrometer at the European Spallation Source. The instrument allows a neutron bandwidth of Δλ = 1.74 Å to reach the sample. The polychromatic flux can reach 6 × 109 n/s/cm2 while retaining a relative energy resolution, δEi/Ei, of around 3.5% at Ei = 5 meV. A fast pulse-shaping chopper allows for flexibility in the primary spectrometer resolution. For an opening time of 0.1 ms, a relative energy resolution down to 0.2% is achieved for Ei = 12 meV. The secondary spectrometer consists of 45 analyzer arrays, populating 9 scattering angle channels in the horizontal scattering plane, each of which covers 5.2° in scattering angle. Each channel hosts 5 analyzer arrays reflecting neutrons of fixed energies Ef equal to 2.7, 3.2, 3.8, 4.4, and 5.0 meV. Utilizing the prismatic analyzer concept, the back-end geometry allows a secondary spectrometer energy resolution in the range of 0.02–0.05 meV. The unique design of BIFROST offers not only an unprecedented neutron flux but also the ability to adjust the energy resolution by more than one order of magnitude. Focusing on the horizontal scattering plane, the spectrometer is ideally suited for extreme environment studies and for studying samples much smaller than 1 cm3. The drastic increase in measurement efficiency, compared to current high-flux spectrometers, has a particularly high impact on the fields of quantum magnetism, unconventional superconductivity, and functional materials.

2 January 2024 in Neutron News
Verified
Journal Article
Open access
AMAndrew R. McCluskey
Andrew R. McCluskey
PAPetra Aulin
Petra Aulin
FBFredrik Bolmsten
Fredrik Bolmsten
MBMads Bertelsen
Mads Bertelsen
CLCarina M. C. Lobley
Carina M. C. Lobley
TRThomas Holm Rod
Thomas Holm Rod

17 July 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
ZMZhanwen Ma
Zhanwen Ma
JLJakob Lass
Jakob Lass
DMDaniel G. Mazzone
Daniel G. Mazzone
GSGediminas Simutis
Gediminas Simutis
STSascha Thürsam
Sascha Thürsam
CKChristine Klauser
Christine Klauser

1 November 2024 in Journal of Neutron Research
Verified
Journal Article
Open access
JRJosé Ignacio Robledo
José Ignacio Robledo
Klaus LieutenantKlaus Lieutenant
Klaus Lieutenant
PWPeter Willendrup
Peter Willendrup
In this work, we present the development of small-angle scattering components in McStas that describe the neutron interaction with 70 different form and structure factors. We describe the considerations taken into account for the generation of these components, such as the incorporation of polydispersity and orientational distribution effects in the Monte Carlo simulation. These models can be parallelized by means of multi-core simulations and graphical processing units. The acceleration schemes for the aforementioned models are benchmarked, and the resulting performance is presented. This allows the estimation of computation times in high-throughput virtual experiments. The presented work enables the generation of large datasets of virtual experiments that can be explored and used by machine learning algorithms.

21 June 2026 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Open access
MBMads Bertelsen
Mads Bertelsen
PWPeter K. Willendrup
Peter K. Willendrup
SYSunyoung Yoo
Sunyoung Yoo
AMAdriano Meligrana
Adriano Meligrana
DMDavid McDonagh
David McDonagh
AFAaron D. Finke
Aaron D. Finke
Monte Carlo neutron ray-tracing simulations of time-of-flight (TOF)–Laue neutron macromolecular crystal diffraction ( n -MX) using the McStas software package were performed for the upcoming NMX Macromolecular Diffractometer at the European Spallation Source. Splitting neutron rays that arrive at the crystal leads to dramatic improvements in event formation with minimal computational overhead. The simulated event-probability data were sampled using a new single-pass weighted reservoir-sampling method, and processed like real n -MX data using DIALS . The effects of air and beamstop scatter on simulated data were investigated.