Hiroshi Horiguchi

Hiroshi Horiguchi

Auto-generated profile, based on publicly available information

Hiroshi Horiguchi

Affiliation Department of Ophthalmology, The Jikei University School of Medicine, Minato-ku, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2014 in Cerebral Cortex
Verified
Journal Article
Open access
PDF file
HHHiroshi Horiguchi
Hiroshi Horiguchi
BWBrian A. Wandell
Brian A. Wandell
JWJonathan Winawer
Jonathan Winawer
A multiplicity of sensory and cognitive functions has been attributed to the large cortical region at the temporo-parietal junction (TPJ). Using functional MRI, we report that a small region lateralized within the right TPJ responds robustly to certain simple visual stimuli (“vTPJ”). The vTPJ was found in all right hemispheres (n = 7), posterior to the auditory cortex. To manipulate stimuli and attention, subjects were presented with a mixture of visual and auditory stimuli in a concurrent block design in 2 experiments: (1) A simple visual stimulus (a grating pattern modulating in mean luminance) elicited robust responses in the vTPJ, whether or not the subject attended to vision and(2) a drifting low-contrast dartboard pattern of constant mean luminance evoked robust responses in the vTPJ when it was task-relevant (visual task), and smaller responses when it was not (auditory task). The results suggest a focal, visually responsive region within the right TPJ that is powerfully driven by certain visual stimuli (luminance fluctuations), and that can be driven by other visual stimuli when the subject is attending. The precise localization of this visually responsive region is helpful in segmenting the TPJ and to better understand its role in visual awareness and related disorders such as extinction and neglect.

15 September 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NINaoko Ishiguro
Naoko Ishiguro
HHHiroshi Horiguchi
Hiroshi Horiguchi
SKSatoshi Katagiri
Satoshi Katagiri
TSTakuya Shiba
Takuya Shiba
TNTadashi Nakano
Tadashi Nakano
Cataract surgery impinges on the spatial properties and wavelength distribution of retinal images, which changes the degree of light-induced visual discomfort/photophobia. However, no study has analyzed the alteration in photophobia before and after cataract surgery or the association between retinal spatial property and photophobia. Here, we measured the higher-order aberrations (HOAs) of the entire eye and the subjective photophobia score. This study investigated 71 eyes in 71 patients who received conventional cataract surgery. Scaling of photophobia was based on the following grading system: when the patient is outdoor on a sunny day, score of 0 and 10 points were assigned to the absence of photophobia and the presence of severe photophobia prevents eye-opening, respectively. We decomposed wavefront errors using Zernike polynomials for a 3-mm pupil diameter and analyzed the association between photophobia scores and HOAs with Spearman’s rank sum correlation (rs). We classified patients into two groups: photophobia (PP) unconcerned included patients who selected 0 both preoperatively or postoperatively and PP concerned included the remaining patients. After cataract surgery, photophobia scores increased, remained unchanged (stable), and decreased in 3, 41, and 27 cases, respectively. In the stable group, 35 of 41 cases belonged to PP unconcerned. In PP concerned, there were significant correlations between photophobia score and postoperative root-mean-square values of total HOAs (rs = 0.52, p = 0.002), total coma (rs = 0.52, p = 0.002), total trefoil (rs = 0.47, p = 0.006), and third-order group (rs = 0.53, p = 0.002). In contrast, there was no significant correlation between photophobia scores and preoperative HOAs. Our results suggest that the spatial properties of retinal image modified by HOAs may affect the degree of photophobia. Scattering light due to cataracts could contribute to photophobia more than HOAs, which may mask the effect of HOAs for photophobia preoperatively.

18 December 2023 in International Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
KSKyohei Sugawara
Kyohei Sugawara
RIRyosuke Ito
Ryosuke Ito
HHHiroshi Horiguchi
Hiroshi Horiguchi
KMKei Mizobuchi
Kei Mizobuchi
SKSatoshi Katagiri
Satoshi Katagiri
TNTadashi Nakano
Tadashi Nakano
AIM: To compare the surgical outcomes of a multifocal intraocular lens (IOL; Lentis Comfort LS-313 MF15) with those of an enhanced monofocal IOL (Tecnis Eyhance DIB00V). METHODS: This retrospective study included patients who underwent cataract surgery with LS-313 MF15 or Eyhance IOL implantation. Data regarding patient demographics, surgical records, and ophthalmic examination before the cataract surgery and one and three months postoperatively were collected. Visual acuities, refractive values, defocus curves, contrast sensitivities and subjective symptoms were evaluated. RESULTS: Among the 71 eyes (47 patients) included in this study, 32 eyes (20 patients) underwent LS-313 MF15 IOL implantation, and 39 eyes (27 patients) underwent Eyhance IOL implantation. No significant differences were observed in age, axial length, or refractive error between the two groups preoperatively. Furthermore, the distance-corrected and uncorrected distance visual acuities one month postoperatively did not differ between the groups, and both groups had sufficient visual acuities at the distances of 5, 1 m, 70, 50, and 30 cm. Other ophthalmic data, including subjective symptoms based on the 14-item Visual Function Index Questionnaire, monocular defocus curves, contrast sensitivities, and halo and glare, did not differ between the groups three months postoperatively. Moreover, both groups had good outcomes. The spherical equivalent one month postoperatively was significantly myopic in the LS-313 MF15 group compared with that in the Eyhance group (P=0.033); however, this difference was not observed three months postoperatively (P=0.471). CONCLUSION: Comparison of the surgical outcomes of LS-313 MF15 with those of Eyhance with different optical properties reveal that both IOLs show good postoperative outcomes, with no significant differences being noted between the two IOLs.

1 September 2020 in American Journal of Ophthalmology Case Reports
Verified
Journal Article
Open access
HHHiroshi Horiguchi
Hiroshi Horiguchi
MKMei Kurosawa
Mei Kurosawa
TSTakuya Shiba
Takuya Shiba
We describe a case of posterior capsule rupture during femtosecond laser-assisted cataract surgery (FLACS) due to direct exposure of the posterior capsule to the laser beam. A 47-year-old man underwent FLACS for anterior capsule opacity. The CATALYS® system automatically detected the posterior capsule from the optical coherence tomography (OCT) images, after which the operator manually adjusted the line of posterior capsule. Femtosecond laser irradiation was presumed to be completed successfully. However, upon insertion of a phaco-tip, the diced nucleus of the lens dropped into the vitreous chamber. Reviewing intraoperative OCT images of the treatment summary to check the area irradiated by laser, an arc-shaped high-intensity area was observed behind the posterior capsule. This high-intensity was misinterpreted as the posterior capsule, which led to error in application of laser beam during procedure. Comparison of data acquired using different imaging modalities could enable correct identification of the posterior capsule.

1 January 2025 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
RSRyuichi Shimada
Ryuichi Shimada
SKSatoshi Katagiri
Satoshi Katagiri
HHHiroshi Horiguchi
Hiroshi Horiguchi
TNTadashi Nakano
Tadashi Nakano
YKYoshihiro Kitazawa
Yoshihiro Kitazawa
Purpose: To design formulas for predicting postoperative vaults in vertical implantable collamer lens (ICL) implantation and to achieve more precise predictions using machine learning models. Design: Retrospective, observational study. Setting: Eye Clinic Tokyo Methods: We retrospectively reviewed the medical records of 720 eyes in 408 patients who underwent vertical ICL implantation. The data included age, sex, refractions, anterior segment biometric data, and surgical records. We designed 3 formulas (named V1 to V3 formulas) using multiple linear regression analysis and tested 4 machine learning models. Results: Predicted vaults by V1 to V3 formulas were 444.17 ± 93.83 μm, 444.08 ± 98.64 μm, and 444.27 ± 108.81 μm, with a mean absolute error of 127.97 ± 107.92 μm, 126.41 ± 105.86 μm, and 122.90 ± 103.00 μm, respectively. There were no significant differences in error among the V1 to V3 formulas, despite the fact that the V1 and V2 formulas referred to limited parameters (3 and 4, respectively) and the V3 formula referred to all 12 parameters. 2 of 4 machine learning models—Extreme Gradient Boosting and Random Forest Regressor—showed better performance in predicted vaults: 444.52 ± 120.51 μm and 446.00 ± 102.55 μm, and mean absolute error: 118.31 ± 100.55 μm and 118.63 ± 99.34 μm, respectively. Conclusions: This is the first study to design V1 to V3 formulas for vertical ICL implantation. The V1 and V2 formulas exhibited good performance despite the limited parameters. In addition, 2 of the 4 machine learning models predicted more precise results.

9 January 2021 in Japanese Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
HHHiroshi Horiguchi
Hiroshi Horiguchi
ESEiji Suzuki
Eiji Suzuki
HKHiroyuki Kubo
Hiroyuki Kubo
TFTakashi Fujikado
Takashi Fujikado
SASanae Asonuma
Sanae Asonuma
SNSatoshi Nakadomari
Satoshi Nakadomari