Linjian Li

Linjian Li

Auto-generated profile, based on publicly available information

Linjian Li

National Research Center of Pumps, Jiangsu University, Zhenjiang, Jiangsu 212013, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
HWHongliang Wang
Hongliang Wang
BLBing Long
Bing Long
CWChuan Wang
Chuan Wang
CHchen Han
chen Han
LLLinjian Li
Linjian Li
An impeller blade with a slot structure can affect the velocity distribution in the impeller flow passage of the centrifugal pump, thus affecting the pump’s performance. Various slot structure geometric parameter combinations were tested in this study to explore this relationship: slot position p, slot width b1, slot deflection angle β, and slot depth h with (3–4) levels were selected for each factor on an L16 orthogonal test table. The results show that b1 and h are the major factors influencing pump performance under low and rated flow conditions, while p is the major influencing factor under the large flow condition. The slot structure close to the front edge of the impeller blade can change the low-pressure region of the suction inlet of the impeller flow passage, thus improving the fluid velocity distribution in the impeller. Optimal slot parameter combinations according to the actual machining precision may include a small slot width b1, slot depth h of ¼ b, slot deflection angle β of 45°–60°, and slot position p close to the front edge of the blade at 20–40%.