Masanobu Manabe

Masanobu Manabe

Auto-generated profile, based on publicly available information

Masanobu Manabe

Division of Sustainable Energy and Environmental Engineering, Graduate School of Engineering, Osaka University, Yamada-oka 2-1, Suita, Osaka 565-0871, Japan

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
MMMasanobu Manabe
Masanobu Manabe
FSFuminobu Sato
Fuminobu Sato
IMIsao Murata
Isao Murata

1 July 2017 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
XGXingcai Guan
Xingcai Guan
MMMasanobu Manabe
Masanobu Manabe
STShingo Tamaki
Shingo Tamaki
FSFuminobu Sato
Fuminobu Sato
IMIsao Murata
Isao Murata
TWTieshan Wang
Tieshan Wang

1 January 2012 in Progress in Nuclear Science and Technology
Verified
Journal Article
Closed access
SNSoichiro Nakamura
Soichiro Nakamura
TMTaiki Mukai
Taiki Mukai
MMMasanobu Manabe
Masanobu Manabe
IMIsao Murata
Isao Murata

31 December 2016 in Journal of Radiation Protection and Research
Verified
Journal Article
Open access
MMMasanobu Manabe
Masanobu Manabe
RORyosuke Ohya
Ryosuke Ohya
NSNobuhide Saraue
Nobuhide Saraue
FSFuminobu Sato
Fuminobu Sato
IMIsao Murata
Isao Murata
Background: Boron Neutron Capture Therapy (BNCT) is a new radiation therapy. In BNCT, there exists some very critical problems that should be solved. One of the severest problems is that the treatment effect cannot be known during BNCT in real time. We are now developing a SPECT (single photon emission computed tomography) system (BNCT-SPECT), with a cadmium telluride (CdTe) semiconductor detector. BNCT-SPECT can obtain the BNCT treatment effect by measuring 478 keV gamma-rays emitted from the excited state of 7 Li nucleus created by 10 B(n,α) 7 Li reaction. In the previous studies, we investigated the feasibility of the BNCT-SPECT system. As a result, the S/N ratio did not meet the criterion of S/N > 1 because deterioration of the S/N ratio occurred caused by the influence of Compton scattering especially due to capture gamma-rays of hydrogen. Materials and Methods: We thus produced an arrayed detector with two CdTe crystals to test cross talk phenomenon and to examine an anti-coincidence detection possibility. For more precise analysis for the anti-coincidence detection, we designed and made a collimator having a similar performance to the real BNCT-SPECT. Results and Discussion: We carried out experiments with the collimator to examine the effect of cross talk of scattering gamma-rays between CdTe elements more practically. As a result of measurement the coincidence events were successfully extracted. Conclusion: We are now planning to carry out evaluation of coincidence rate from the measurement and comparison of it with the numerical calculations.