Nasir Ali

Nasir Ali

Auto-generated profile, based on publicly available information

Nasir Ali

Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON, Canada

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
NANasir Ali
Nasir Ali
QGQiang Gao
Qiang Gao
PSPavel Sovicka
Pavel Sovicka
PMPavol Makys
Pavol Makys
MSMarek Stulrajter
Marek Stulrajter
KMKe Ma
Ke Ma
Exceptional robust configuration and fault tolerance capabilities make switched reluctance motors (SRMs) a promising technology for automotive applications. Nevertheless, the power transistors in a power converter of an SRM drive are well–considered more vulnerable, compared to the SRM itself. Therefore, accurate and early stage fault detection is crucial for such safety-critical applications. This paper investigates the usage of high-frequency (HF) signal injection for real-time fault identification and localization of power transistors in SRM drives. Unlike the existing diagnostic schemes that often use extra current/voltage sensors and complex algorithms, this simple method injects a sinusoidal HF voltage signal into a standard asymmetrical half-bridge converter-fed SRM. Then the induced HF current is filtered from the fundamental current and its frequency is estimated in real-time for fault localization. Typical power transistor faults (open-circuit and short-circuit) and their location can be effectively detected in the earliest stage by monitoring the variations in the filtered HF signal as well as the fundamental current with the occurrence of the faults. The effectiveness of the proposed diagnostic strategy is validated by thorough simulation and experimental results carried out on a three–phase 12/8 SRM drive system.

17 April 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
NANasir Ali
Nasir Ali
Qingsong WangQingsong Wang
Qingsong Wang
QGQiang Gao
Qiang Gao
KMKe Ma
Ke Ma
Switched reluctance motors (SRMs) are considered a potential candidate for utilization in numerous safety-critical applications including electric vehicles (EVs) and more/all electric aircraft (MEA), etc., where the reliability of the drive system is critically important. An SRM drive system suffers from various electrical, mechanical, and sensor faults during operation. The existing fault detection schemes investigated each fragile component separately and proposed different approaches for each fault, which not only make the system complex but also less reliable for real-time implementation in safety-critical applications. Thus, a more sophisticated algorithm to detect and discriminate each of these faults in real time becomes attractive. A simple fault detection and isolation scheme for multiple faults in SRM drive systems is reported in this paper. The investigated faults include open- and short-circuit faults in power switches, open-phase winding, and zero-output current sensors faults. An auxiliary phase current for each phase was reconstructed from the dc-link and the faults are identified and discriminated effectively through the digital analysis of the fundamental current and the auxiliary current in real-time. The feasibility of the proposed scheme is verified by the extensive simulation and experiments conducted on a three-phase 12/8 SRM drive system.

23 April 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
NANasir Ali
Nasir Ali
Mehdi NarimaniMehdi Narimani
Mehdi Narimani
Fault tolerance in electric motor drives has been extensively studied due to their widespread usage in safety-critical applications, including more/all-electric aircraft and electric vehicles. Switched reluctance motors (SRMs) are renowned for their high robustness and excellent fault tolerance. However, they are not immune to faults, and a potential fault in any part of the motor drive could have serious implications for the system, even may lead to unexpected shutdown if the fault is not promptly remedied. The power converter is a key component and the most vulnerable to failure, as reported for 35% of the drive faults. Fault tolerance has typically been achieved through a combination of hardware and software reconfigurations. However, due to the simple structure of the standard asymmetrical half-bridge converter, hardware reconfiguration is more commonly used to remediate converter faults. Consequently, fault tolerance adds cost and complexity to a standard SRM drive system. This article presents an instructive survey of the recent research on fault-tolerant SRM drives. Moreover, the postfault performance, implementation costs, and fault-tolerant capabilities of advanced fault-tolerant converters are systematically quantified, evaluated and compared. Finally, the article is concluded with an investigation on the future research trends in fault tolerance in SRM drives.

7 July 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
NANasir Ali
Nasir Ali
Qingsong WangQingsong Wang
Qingsong Wang
QGQiang Gao
Qiang Gao
KMKe Ma
Ke Ma
Switched reluctance motors (SRMs) have been widely used in reliability-critical applications due to their robust rotor structure and fault-tolerance characteristics. However, power transistors in the SRM drives still suffer from various faults, such as open-circuit and short-circuit faults, which may cause unexpected shutdowns. Therefore, detection and localization of the power transistor faults in the earliest stage is of extreme importance to ensure uninterrupted operations. This paper proposes a fast fault diagnostic technique for power transistor faults in the SRM drive system. When a fault-caused abnormal current pattern is observed in the fundamental current, two complementary high-frequency (HF) pulses are injected into both power switches of the affected phase for a transient period. Through analyzing the relationship between the induced phase currents due to the injected HF pulses and the failure cases, two fault variables are introduced for faulty switch localization. Diagnosis of open-circuit and short-circuit faults in a single switch and dual switches is achieved within one period of the injected HF pulses. The fast diagnostic speed and feasibility of the proposed method for real-time implementation is verified through simulation studies and experiments based on a three-phase 12/8-pole SRM drive system.

1 January 2015 in Materials Today: Proceedings
Verified
Journal Article
Closed access
NANasir Ali
Nasir Ali
MBMahwish Bashir
Mahwish Bashir
SBShafaq Batool
Shafaq Batool
SRSaira Riaz
Saira Riaz
SNShahzad Naseem
Shahzad Naseem

2 September 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
NANasir Ali
Nasir Ali
SQShuo Qu
Shuo Qu
Mehdi NarimaniMehdi Narimani
Mehdi Narimani
Switched reluctance motors (SRMs) are recognized as a promising technology for electrified transportation due to their fault-tolerant and rare-earth free features. In transportation applications, particularly in powertrains of the railways and aircraft, the reliability of every component in the motor drive system is of paramount importance. Existing state-of-the-art diagnostic approaches address faults in each component separately, leading to increased system complexity. Therefore, a single algorithm for real-time diagnosis of multiple component faults becomes an attractive solution. This article presents a simple yet comprehensive technique for detecting and locating nearly all potential electrical faults and current sensor faults in SRM drives at their earliest stages. The proposed diagnostic scheme can effectively identify ten failure cases, including open-circuit and short-circuit faults in power switches, power diodes, phase winding open-circuit faults, and zero-output current sensor faults. Fundamental current and modified dc-bus currents are used for developing fault features, thereby avoiding additional costs and complexity. Digital logic judgments are developed based on the measured currents for fault localization. Simulation studies and rigorous experiments are conducted on a three-phase 12/8 SRM drive system to validate the feasibility and superior performance of the diagnostic scheme.