Guan-Yuh Ho

Guan-Yuh Ho

Auto-generated profile, based on publicly available information

Guan-Yuh Ho

Department of Otorhinolaryngology, Medical University of Vienna, Austria

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2019 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Open access
PDF file
GHGuan-Yuh Ho
Guan-Yuh Ho
MLMatthias Leonhard
Matthias Leonhard
DDDoris-Maria Denk-Linnert
Doris-Maria Denk-Linnert
BSBerit Schneider-Stickler
Berit Schneider-Stickler
Purpose: Persistent unilateral vocal fold paralysis (UFVP) with glottal insufficiency often requires type I medialization thyroplasty (MT). Previous implants cannot be adjusted postoperatively if necessary. The newly developed APrevent®VOIS implant (VOIS) can provide postoperative re-adjustment to avoid revision MT. The objective of this pilot study is to evaluate the VOIS intraoperatively concerning voice improvement, surgical feasibility and device handling.Methods: During routine MT, VOIS was applied short time in eight patients before the regular implantation of the Titanium Vocal Fold Medialization Implant (TVFMI™). In all patients, perceptual voice sound analysis using R(oughness)–B(reathiness)–H(oarseness)-scale, measurement of M(aximum)–P(honation)–T(ime) and glottal closure in videolaryngoscopy were performed before and after implanting VOIS/TVFMI™. Acoustic analyses of voice recordings were performed using freeware praat. Surgical feasibility, operative handling and device fitting of VOIS and TVFMI™ were assessed by the surgeon using V(isual)-A(nalog)-S(cale). Data were statistically analyzed with pairedttest.Result: All patients showed significant improvement of voice sound parameters after VOIS/TVFMI™ implantation. The mean RBH-scale improved from preoperativeR = 2.1,B = 2.3,H = 2.5 toR = 0.6,B = 0.3,H = 0.8 after VOIS andR = 0.5,B = 0.3,H = 0.8 after TVFMI™ implantation. The mean MPT increased from preoperative 7.9 to 14.6 s after VOIS and 13.8 s after TVFMI™ implantation. VOIS/TVFMI™ achieved complete glottal closure in 7/8 patients. The satisfaction with intraoperative device fitting and device handling of VOIS was as good as that of TVFMI™.Conclusion: The novel APrevent®VOIS implant showed similar intraoperative voice improvement compared to routinely used TVFMI™ without adverse device events and with safe device fitting.

31 March 2023 in Folia Phoniatrica et Logopaedica
Verified
Journal Article
Open access
PDF file
RPRoland Paulus
Roland Paulus
MLMatthias Leonhard
Matthias Leonhard
GHGuan-Yuh Ho
Guan-Yuh Ho
AKAnnabella Kurz
Annabella Kurz
BSBerit Schneider-Stickler
Berit Schneider-Stickler
Introduction: The conventional rigid-90° and rigid-70° laryngostroboscopy has been so far considered the gold standard in assessing the vibratory behavior of the vocal folds and the glottal closure configuration during phonation. Meanwhile, this rigid laryngostroboscopy is more and more replaced by flexible chip-on-tip systems. The aim of this study was to evaluate the influence of these different endoscopic techniques on glottal closure configuration and on visibility of the complete focal fold length including anterior commissure during phonation. Methods: Twenty-one euphonic subjects were enrolled (mean age 34.6 ± 9.5; m = 10, f = 11). They were examined with the three laryngoscopic techniques (conventional rigid-90°, rigid-70°, and flexible chip-on-tip laryngoscopy during low and high voice pitch with soft and loud voice intensity). For evaluating the degree of glottal closure, a modified classification of Södersten et al. was applied and the visibility of the anterior commissure was evaluated. The correlation of the three endoscopic techniques was assessed with Cohen and Fleiss’ kappa. Results: In even low loud phonation, the rigid-90° and rigid-70° endoscopies revealed a complete closure of the glottis in only 47.6% of subjects but with flexible endoscopy in 81%. The complete vocal fold length with anterior commissure was best visible with flexible endoscopy in 90.5% in low-soft and high-soft phonation. The rigid-90° endoscopy showed a slight agreement in comparison with the flexible endoscopy in regard to the types of vocal fold closure with a Cohen’s kappa coefficient k = 0.199. The rigid-90° endoscopy showed an almost perfect agreement with k = 0.84 when compared to the rigid-70° endoscopy. The flexible endoscopy compared to the rigid-70° endoscopy showed a fair agreement with k = 0.346. Conclusion: We found mainly corresponding results in both rigid-90° and rigid-70° endoscopic techniques which can be explained by the same transoral approach with the tongue pulled out, whereas the flexible transnasal endoscopy mainly gives a better view on the anterior commissure. The influence of transorally or transnasally guided endoscopic techniques needs to be considered in interpretation of laryngostroboscopic parameters like vocal fold closure and supraglottal hyperactivity.

28 March 2022 in Folia Phoniatrica et Logopaedica
Verified
Journal Article
Open access
PDF file
GHGuan-Yuh Ho
Guan-Yuh Ho
IKInes Kristina Kansy
Ines Kristina Kansy
KKKatharina Anna Klavacs
Katharina Anna Klavacs
MLMatthias Leonhard
Matthias Leonhard
BSBerit Schneider-Stickler
Berit Schneider-Stickler
Introduction: Voice diagnostics including voice range profile (VRP) measurement and acoustic voice analysis is essential in laryngology and phoniatrics. Due to COVID-19 pandemic, wearing of 2 or 3 filtering face piece (FFP2/3) masks is recommended when high-risk aerosol-generating procedures like singing and speaking are being performed. Goal of this study was to compare VRP parameters when performed without and with FFP2/3 masks. Further, formant analysis for sustained vowels, singer’s formant, and analysis of reading standard text samples were performed without/with FFP2/3 masks. Methods: Twenty subjects (6 males and 14 females) were enrolled in this study with an average age of 36 ± 16 years (mean ± SD). Fourteen patients were rated as euphonic/not hoarse and 6 patients as mildly hoarse. All subjects underwent the VRP measurements, vowel, and text recordings without/with FFP2/3 mask using the software DiVAS by XION medical (Berlin, Germany). Voice range of singing voice, equivalent of voice extension measure (eVEM), fundamental frequency (F0), sound pressure level (SPL) of soft speaking and shouting were calculated and analyzed. Maximum phonation time (MPT) and jitter-% were included for Dysphonia Severity Index (DSI) measurement. Analyses of singer’s formant were performed. Spectral analyses of sustained vowels /a:/, /i:/, and /u:/ (first = F1 and second = F2 formants), intensity of long-term average spectrum, and alpha-ratio were calculated using the freeware praat. Results: For all subjects, the mean values of routine voice parameters without/with mask were analyzed: no significant differences were found in results of singing voice range, eVEM, SPL, and frequency of soft speaking/shouting, except significantly lower mean SPL of shouting with FFP2/3 mask, in particular that of the female subjects (p = 0.002). Results of MPT, jitter, and DSI without/with FFP2/3 mask showed no significant differences. Further mean values analyzed without/with mask were ratio singer’s formant/loud singing, with lower ratio with FFP2/3 mask (p = 0.001), and F1 and F2 of /a:/, /i:/, /u:/, with no significant differences of the results, with the exception of F2 of /i:/ with lower value with FFP2/3 mask (p = 0.005). With the exceptions mentioned, the t test revealed no significant differences for each of the routine parameters tested in the recordings without and with wearing a FFP2/3 mask. Conclusion: It can be concluded that VRP measurements including DSI performed with FFP2/3 masks provide reliable data in clinical routine with respect to voice condition/constitution. Spectral analyses of sustained vowel, text, and singer’s formant will be affected by wearing FFP2/3 masks.

22 August 2025 in Folia Phoniatrica et Logopaedica
Verified
Journal Article
Open access
GHGuan-Yuh Ho
Guan-Yuh Ho
MLMatthias Leonhard
Matthias Leonhard
AMAndreas H. Mueller
Andreas H. Mueller
GFGerhard Foerster
Gerhard Foerster
LHLi-Chun Hsieh
Li-Chun Hsieh
BSBerit Schneider-Stickler
Berit Schneider-Stickler
Introduction: Type I medialization thyroplasty (MT) is one of the standard procedures in patients having permanent unilateral vocal fold paralysis (UVFP) with insufficient glottal closure. The objective of this study was to evaluate the clinical outcome in patients with UVFP 7 weeks post-implantation using the novel APrevent® VOIS (VOIS) implant with its adjustable balloon. Methods: The VOIS implant was applied in 32 patients with UVFP during MT. The following parameters were assessed pre- and 7 weeks post-implantation: glottal closure according to Södersten and Lindestad classification (videolaryngostroboscopy), perceptual voice assessment (GRBAS scores), acoustic voice parameters (jitter %, shimmer Db, and harmonic to noise ratio [HNR in dB]), maximum phonation time (MPT in s), voice range profile (VRP), as well as the subjective voice rating of patients (voice handicap index [VHI-30]). Results: Significant improvement in glottal closure was achieved in 28 patients (87.5%) 7 weeks after MT with VOIS implant. Adjustment via emptying and refilling of the incorporated balloon of the implant was necessary in 5 patients to further improve or restore the glottal closure. The mean GRBAS scores improved from preoperatively Gpre = 2.6 ± 0.5, Rpre = 2.4 ± 0.7, Bpre = 2.3 ± 0.8, Apre = 1.9 ± 0.8, Spre = 1.7 ± 0.8 to postoperatively Gpost = 0.7 ± 0.7, Rpost = 0.8 ± 0.8, Bpost = 0.3 ± 0.6, Apost = 0.3 ± 0.5, Spost = 0.3 ± 0.4. The mean MPT improved from 4.4 ± 2.6 s preoperatively to 9.0 ± 5.8 s postoperatively. All acoustic voice parameters showed significant improvement as well. The mean jitter % reduced from preoperative 2.80 ± 8.89% to postoperative 0.70 ± 0.73, the mean shimmer dB from 1.18 ± 0.48 dB to 0.70 ± 0.73 dB, whereas the HNR gained from 12.19 ± 6.96 dB to 18.36 ± 4.87 dB, respectively. Within the VRP, the intensity level (I-levelshouting [dB]) and fundamental frequency (F0shouting [Hz]) in the shouting voice showed improvement as well. The I-levelshouting improved from 69.4 ± 12.7 dB preoperatively to 72.5 ± 13.3 dB postoperatively and the F0shouting from 214.2 ± 64.0 to 230.2 ± 62.6 Hz, respectively. Post-VOIS implantation, the mean VHI-30 score significantly reduced from preoperative 72.1 ± 20.5 to postoperative 19.2 ± 18.5. No complications were observed both intra- and postoperatively. All described improvements reached statistical significance with p < 0.05. Conclusion: The novel VOIS implant can be applied safely in patients with UVFP. Patients can further benefit from the intra- and postoperative adjustment, especially that of the posterior glottal closure using the custom-fitting option by re-filling the balloon of the implant. To better evaluate the sustainability of the VOIS implant in terms of safety and effectiveness for patients with UFVP, it is crucial to conduct further analysis of long-term outcomes post-implantation in future studies.

24 May 2022 in Laryngo-Rhino-Otologie
Verified
Journal Article
Open access
AKAnnabella Kurz
Annabella Kurz
BSBerit Schneider-Stickler
Berit Schneider-Stickler
AKAnna-Maria Kuttenreich
Anna-Maria Kuttenreich
MLMatthias Leonhard
Matthias Leonhard
GHGuan-Yuh Ho
Guan-Yuh Ho
Gerd Fabian VolkGerd Fabian Volk
Gerd Fabian Volk
Hintergrund Die funktionelle Elektrostimulation (FES) mit Oberflächenelektroden kann den Muskeltonus erhöhen und die Musekelatrophie reduzieren, in denervierten oder teilweise reinnervierten Muskeln. Wir vergleichen die Stimulationsparameter zweier Studien, die die FES sowohl bei einseitiger Stimmlippenlähmung (UVFP), als auch bei Fazialisparalysen (FP) untersucht haben. Methoden 53 erwachsenen UVFP Patienten und 10 FP wurden ausgewertet. Zur Kehlkopfstimulation wurde ein Oberflächenlektrodenpaar mit befeuchteten Schwammtaschen auf Höhe des gelähmten (Kathode) und gesundem (Anode) des M. thyroarytenoideus befestigt. Bei FP wurden zwei 6x4cm Klebeelektroden über dem denervierten M. zygomaticus angebracht. Mit einem externen Stimulator wurden Dreieckspulse mit 1 Hz, je 500, 250, 100, 50, 25, 10, 1 ms Phasendauer (PD) und 1-20 mA abgegeben. Die Reizschwelle, Nebenwirkungen und die Muskelkontraktion wurden erfasst. Ergebnisse Sowohl bei UVFP als auch bei FP war die effektivsten PD für eine gezielte, Muskelkontraktion des gelähmten Muskels zwischen 50 und 100ms bei einer Reizintensität von durchschnittlich ca. 7 mA. Bei FP wurden die besten Ergebnisse mit Dreiecks-Impulsen, einer PD von 100-250 ms und einer Amplitude von≤5mA beobachtet. Bei UVFP löste eine Amplitude über 6 mA und einer PD von 250 oder 500 ms oft einen Schluckreflex aus. Eine unspezifische Kontraktion von M. infrahyoidei oder Platysma bei UVFP bzw. des M. masseter bei FP wurde mit kurzen PD von 1, 10, oder 25 ms ausgelöst. Schlussfolgerungen Sowohl bei UVFP als auch bei FP sind die gelähmten Muskeln selektiv mit PD von 100ms auslöst. Höhere PD führen bei UVFP eher zur Auslösung des Schluckreflexes und niedrigere PD in beiden Settings zu einer unerwünschten Kontraktion innervierter Muskeln. Med-EL Elektromedizinische Geräte GmbH Article published online: 24 May 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart, Germany

11 February 2026 in Journal of Voice
Verified
Journal Article
Closed access
AKAnnabella Kurz
Annabella Kurz
MLMatthias Leonhard
Matthias Leonhard
GHGuan-Yuh Ho
Guan-Yuh Ho
Gerd Fabian VolkGerd Fabian Volk
Gerd Fabian Volk
OGOliver Galvan
Oliver Galvan
BSBerit Schneider-Stickler
Berit Schneider-Stickler