1 February 2017 in The Lancet
In-utero MRI (iuMRI) has shown promise as an adjunct to ultrasound but the comparative diagnostic performance has been poorly defined. We aimed to assess whether the diagnostic accuracy and confidence of the prenatal diagnosis of fetal brain abnormalities is improved with iuMRI and assess the clinical impact and patient acceptability of iuMRI. We did a multicentre, prospective, cohort study in the UK, at 16 fetal medicine centres, of pregnant women aged 16 years or older whose fetus had a brain abnormality detected by ultrasound at a gestational age of 18 weeks or more, had no contraindications to iuMRI, and consented to enter the study. Women carrying a fetus suspected of having a brain anomaly on ultrasound had iuMRI done within 14 days of ultrasound. The findings were reviewed by two independent panels and used to estimate diagnostic accuracy and confidence by comparison with outcome diagnoses. Changes in diagnosis, prognosis, and clinical management brought about by iuMRI and patient acceptability were assessed. Participants were recruited between July 29, 2011, and Aug 31, 2014. The cohort was subdivided by gestation into the 18 weeks to less than 24 weeks fetus cohort (n=369) and into the 24 weeks or older fetus cohort (n=201). Diagnostic accuracy was improved by 23% (95% CI 18-27) in the 18 weeks to less than 24 weeks group and 29% (23-36) in the 24 weeks and older group (p<0·0001 for both groups). The overall diagnostic accuracy was 68% for ultrasound and 93% for iuMRI (difference 25%, 95% CI 21-29). Dominant diagnoses were reported with high confidence on ultrasound in 465 (82%) of 570 cases compared with 544 (95%) of 570 cases on iuMRI. IuMRI provided additional diagnostic information in 387 (49%) of 783 cases, changed prognostic information in at least 157 (20%), and led to changes in clinical management in more than one in three cases. IuMRI also had high patient acceptability with at least 95% of women saying they would have an iuMRI study if a future pregnancy were complicated by a fetal brain abnormality. iuMRI improves diagnostic accuracy and confidence for fetal brain anomalies and leads to management changes in a high proportion of cases. This finding, along with the high patient acceptability, leads us to propose that any fetus with a suspected brain abnormality on ultrasound should have iuMRI to better inform counselling and management decisions. National Institute for Health Research Health Technology Assessment programme.
1 September 2019 in Health Technology Assessment
Background: Ultrasonography has been the mainstay of antenatal screening programmes in the UK for many years. Technical factors and physical limitations may result in suboptimal images that can lead to incorrect diagnoses and inaccurate counselling and prognostic information being given to parents. Previous studies suggest that the addition of in utero magnetic resonance imaging (iuMRI) may improve diagnostic accuracy for fetal brain abnormalities. These studies have limitations, including a lack of an outcome reference diagnosis (ORD), which means that improvements could not be assessed accurately.Objectives: To assess the diagnostic impact, acceptability and cost consequence of iuMRI among fetuses with a suspected fetal brain abnormality.Design: A pragmatic, prospective, multicentre, cohort study with a health economics analysis and a sociological substudy.Setting: Sixteen UK fetal medicine centres.Participants: Pregnant women aged ≥ 16 years carrying a fetus (at least 18 weeks’ gestation) with a suspected brain abnormality detected on ultrasonography.Interventions: Participants underwent iuMRI and the findings were reported to their referring fetal medicine clinician.Main outcome measures: Pregnancy outcome was followed up and an ORD from postnatal imaging or postmortem autopsy/imaging collected when available. Developmental data from the Bayley Scales of Infant Development and questionnaires were collected from the surviving infants aged 2–3 years. Data on the management of the pregnancy before and after the iuMRI were collected to inform the economic evaluation. Two surveys collected data on patient acceptability of iuMRI and qualitative interviews with participants and health professionals were undertaken.Results: The primary analysis consisted of 570 fetuses. The absolute diagnostic accuracies of ultrasonography and iuMRI were 68% and 93%, respectively [a difference of 25%, 95% confidence interval (CI) 21% to 29%]. The difference between ultrasonography and iuMRI increased with gestational age. In the 18–23 weeks group, the figures were 70% for ultrasonography and 92% for iuMRI (difference of 23%, 95% CI 18% to 27%); in the ≥ 24 weeks group, the figures were 65% for ultrasonography and 94% for iuMRI (difference of 29%, 95% CI 23% to 36%). Patient acceptability was high, with at least 95% of respondents stating that they would have iuMRI again in a similar situation. Health professional interviews suggested that iuMRI was acceptable to clinicians and that iuMRI was useful as an adjunct to ultrasonography, but not as a replacement. Across a range of scenarios, iuMRI resulted in additional costs compared with ultrasonography alone. The additional cost was consistently < £600 per patient and the cost per management decision appropriately changed was always < £3000. There is potential for reporting bias from the referring clinicians on the diagnostic and prognostic outcomes. Lower than anticipated follow-up rates at 3 years of age were observed.Conclusions: iuMRI as an adjunct to ultrasonography significantly improves the diagnostic accuracy and confidence for the detection of fetal brain abnormalities. An evaluation of the use of iuMRI for cases of isolated microcephaly and the diagnosis of fetal spine abnormalities is recommended. Longer-term follow-up studies of children diagnosed with fetal brain abnormalities are required to fully assess the functional significance of the diagnoses.Trial registration: Current Controlled Trials ISRCTN27626961.Funding: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full inHealth Technology Assessment; Vol. 23, No. 49. See the NIHR Journals Library website for further project information.
24 March 2017 in Ultrasound in Obstetrics & Gynecology
21 September 2016 in European Radiology
Objectives This systematic review was undertaken to define the diagnostic performance of in utero MR (iuMR) imaging when attempting to confirm, exclude or provide additional information compared with the information provided by prenatal ultrasound scans (USS) when there is a suspicion of foetal brain abnormality. Methods Electronic databases were searched as well as relevant journals and conference proceedings. Reference lists of applicable studies were also explored. Data extraction was conducted by two reviewers independently to identify relevant studies for inclusion in the review. Inclusion criteria were original research that reported the findings of prenatal USS and iuMR imaging and findings in terms of accuracy as judged by an outcome reference diagnosis for foetal brain abnormalities. Results 34 studies met the inclusion criteria which allowed diagnostic accuracy to be calculated in 959 cases, all of which had an outcome reference diagnosis determined by postnatal imaging, surgery or autopsy. iuMR imaging gave the correct diagnosis in 91 % which was an increase of 16 % above that achieved by USS alone. Conclusion iuMR imaging makes a significant contribution to the diagnosis of foetal brain abnormalities, increasing the diagnostic accuracy achievable by USS alone. Key points • Ultrasound is the primary modality for monitoring foetal brain development during pregnancy • iuMRI used together with ultrasound is more accurate for detecting foetal brain abnormalities • iuMR imaging is most helpful for detecting midline brain abnormalities • The moderate heterogeneity of reviewed studies may compromise findings
1 February 2020 in The Lancet Child & Adolescent Health
In utero MRI (iuMRI) detects fetal brain abnormalities more accurately than ultrasonography and provides additional clinical information in around half of pregnancies. We aimed to study whether postnatal neuroimaging after age 6 months changes the diagnostic accuracy of iuMRI and its ability to predict developmental outcome. Families enrolled in the MERIDIAN study whose child survived to age 3 years were invited to have a case note review and assessment of developmental outcome with the Bayley Scales of Infant and Toddler Development, the Ages and Stages Questionnaire, or both. A paediatric neuroradiologist, masked to the iuMRI results, reviewed the postnatal neuroimaging if the clinical report differed from iuMRI findings. Diagnostic accuracy was recalculated. A paediatric neurologist and neonatologist categorised participants' development as normal, at risk, or abnormal, and the ability of iuMRI and ultrasonography to predict developmental outcome were assessed. 210 participants had case note review, of whom 81 (39%) had additional investigations after age 6 months. The diagnostic accuracy of iuMRI remained higher than ultrasonography (proportion of correct cases was 529 [92%] of 574 vs 387 [67%] of 574; absolute difference 25%, 95% CI 21 to 29; p<0·0001). Developmental outcome data were analysed in 156 participants, and 111 (71%) were categorised as normal or at risk. Of these 111 participants, prognosis was normal or favourable for 56 (51%) using ultrasonography and for 76 (69%) using iuMRI (difference in specificity 18%, 95% CI 7 to 29; p=0·0008). No statistically significant difference was seen in infants with abnormal outcome (difference in sensitivity 4%, 95% CI -10 to 19; p=0·73). iuMRI remains the optimal tool to identify fetal brain abnormalities. It is less accurate when used to predict developmental outcome, although better than ultrasonography for identifying children with normal outcome. Further work is needed to determine how the prognostic abilities of iuMRI can be improved. National Institute for Health Research Health Technology Assessment programme.
24 April 2017 in Ultrasound in Obstetrics & Gynecology