Christopher Michael Orton

Christopher Michael Orton

Auto-generated profile, based on publicly available information

Christopher Michael Orton

Repiratory Department, Royal Brompton Hospital, London, UK

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2021 in Radiology
Verified
Journal Article
Closed access
BVBavithra Vijayakumar
Bavithra Vijayakumar
JTJames Tonkin
James Tonkin
ADAnand Devaraj
Anand Devaraj
KPKeir EJ Philip
Keir EJ Philip
COChristopher M. Orton
Christopher M. Orton
PSPallav L. Shah
Pallav L. Shah
CT abnormalities were common after COVID-19 and linked with disease severity at presentation, but signs of overt fibrosis were uncommon and most morphologic abnormalities regressed over time. Background Data on the long-term pulmonary sequelae in COVID-19 are lacking. Purpose To assess symptoms, functional impairment, and residual pulmonary abnormalities on serial chest CT scans in COVI...

14 December 2022 in The Lancet Respiratory Medicine
Verified
Journal Article
Open access
PSPallav L Shah
Pallav L Shah
COChristopher M Orton
Christopher M Orton
BGBeatriz Grinsztejn
Beatriz Grinsztejn
GDGavin C Donaldson
Gavin C Donaldson
BRBrenda Crabtree Ramírez
Brenda Crabtree Ramírez
OROlivia Pérez Rodríguez
Olivia Pérez Rodríguez
COVID-19 has overwhelmed health services globally. Oral antiviral therapies are licensed worldwide, but indications and efficacy rates vary. We aimed to evaluate the safety and efficacy of oral favipiravir in patients hospitalised with COVID-19. We conducted a multicentre, open-label, randomised controlled trial of oral favipiravir in adult patients who were newly admitted to hospital with proven or suspected COVID-19 across five sites in the UK (n=2), Brazil (n=2) and Mexico (n=1). Using a permuted block design, eligible and consenting participants were randomly assigned (1:1) to receive oral favipiravir (1800 mg twice daily for 1 day; 800 mg twice daily for 9 days) plus standard care, or standard care alone. All caregivers and patients were aware of allocation and those analysing data were aware of the treatment groups. The prespecified primary outcome was the time from randomisation to recovery, censored at 28 days, which was assessed using an intention-to-treat approach. Post-hoc analyses were used to assess the efficacy of favipiravir in patients aged younger than 60 years, and in patients aged 60 years and older. The trial was registered with clinicaltrials.gov, NCT04373733. Between May 5, 2020 and May 26, 2021, we assessed 503 patients for eligibility, of whom 499 were randomly assigned to favipiravir and standard care (n=251) or standard care alone (n=248). There was no significant difference between those who received favipiravir and standard care, relative to those who received standard care alone in time to recovery in the overall study population (hazard ratio [HR] 1·06 [95% CI 0·89–1·27]; n=499; p=0·52). Post-hoc analyses showed a faster rate of recovery in patients younger than 60 years who received favipiravir and standard care versus those who had standard care alone (HR 1·35 [1·06–1·72]; n=247; p=0·01). 36 serious adverse events were observed in 27 (11%) of 251 patients administered favipiravir and standard care, and 33 events were observed in 27 (11%) of 248 patients receiving standard care alone, with infectious, respiratory, and cardiovascular events being the most numerous. There was no significant between-group difference in serious adverse events per patient (p=0·87). Favipiravir does not improve clinical outcomes in all patients admitted to hospital with COVID-19, however, patients younger than 60 years might have a beneficial clinical response. The indiscriminate use of favipiravir globally should be cautioned, and further high-quality studies of antiviral agents, and their potential treatment combinations, are warranted in COVID-19. LifeArc and CW+.

19 April 2022 in Communications Medicine
Verified
Journal Article
Open access
PDF file
COChristopher M. Orton
Christopher M. Orton
HSHenry E. Symons
Henry E. Symons
BMBenjamin Moseley
Benjamin Moseley
JAJustice Archer
Justice Archer
NWNatalie A. Watson
Natalie A. Watson
PSPallav L. Shah
Pallav L. Shah
Background: The coronavirus disease-19 (COVID-19) pandemic led to the prohibition of group-based exercise and the cancellation of sporting events. Evaluation of respiratory aerosol emissions is necessary to quantify exercise-related transmission risk and inform mitigation strategies. Methods: Aerosol mass emission rates are calculated from concurrent aerosol and ventilation data, enabling absolute comparison. An aerodynamic particle sizer (0.54–20 μm diameter) samples exhalate from within a cardiopulmonary exercise testing mask, at rest, while speaking and during cycle ergometer-based exercise. Exercise challenge testing is performed to replicate typical gym-based exercise and very vigorous exercise, as determined by a preceding maximally exhaustive exercise test. Results: We present data from 25 healthy participants (13 males, 12 females; 36.4 years). The size of aerosol particles generated at rest and during exercise is similar (unimodal ~0.57–0.71 µm), whereas vocalization also generated aerosol particles of larger size (i.e. was bimodal ~0.69 and ~1.74 µm). The aerosol mass emission rate during speaking (0.092 ng s−1; minute ventilation (VE) 15.1 L min−1) and vigorous exercise (0.207 ng s−1, p = 0.726; VE 62.6 L min−1) is similar, but lower than during very vigorous exercise (0.682 ng s−1, p < 0.001; VE 113.6 L min−1). Conclusions: Vocalisation drives greater aerosol mass emission rates, compared to breathing at rest. Aerosol mass emission rates in exercise rise with intensity. Aerosol mass emission rates during vigorous exercise are no different from speaking at a conversational level. Mitigation strategies for airborne pathogens for non-exercise-based social interactions incorporating vocalisation, may be suitable for the majority of exercise settings. However, the use of facemasks when exercising may be less effective, given the smaller size of particles produced.

6 January 2023 in Aerosol Science and Technology
Verified
Journal Article
Open access
JHJoshua Harrison
Joshua Harrison
BSBrian Saccente-Kennedy
Brian Saccente-Kennedy
COChristopher M. Orton
Christopher M. Orton
LMLauren P. McCarthy
Lauren P. McCarthy
JAJustice Archer
Justice Archer
BBBryan R. Bzdek
Bryan R. Bzdek
The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has brought renewed attention to respiratory aerosol and droplet generation. While many studies have robustly quantified aerosol (20 µm diameter) generated by a cohort of 76 adults and children using a water-sensitive paper droplet deposition approach. Unvoiced and voiced activities spanning different levels of loudness, different lengths of sustained phonation, and a specific manner of articulation in isolation were investigated. We find that oral articulation drives >20 µm droplet generation, with breathing generating virtually no droplets and speaking and singing generating on the order of 250 droplets min−1. Lip trilling, which requires extensive oral articulation, generated the most droplets, whereas shouting “Hey”, which requires minimal oral articulation, generated relatively few droplets. Droplet size distributions were all broadly consistent, and no significant differences between the children and adult cohorts were identified. By comparing the aerosol and droplet emissions for the same participants, the full size distribution of respiratory aerosol (0.5-1000 µm) is reported. Although 20 µm droplets dominate the mass concentration. Accurate quantification of aerosol concentrations in the 10-70 μm size range remains very challenging; more robust aerosol analysis approaches are needed to characterize this size range. Graphical Abstract

1 July 2025 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Open access
ATAnand Tana
Anand Tana
AVArschang Valipour
Arschang Valipour
AIAlvin Ing
Alvin Ing
DSDaniel Paul Steinfort
Daniel Paul Steinfort
COChristopher M. Orton
Christopher M. Orton
DSDirk-Jan Slebos
Dirk-Jan Slebos
Rationale: Despite advancements in emphysema treatment, high morbidity and mortality rates highlight the need for innovative therapies. A novel self-expanding nitinol airway scaffold was designed to alleviate lung hyperinflation by connecting emphysematous parenchyma with central bronchi, releasing trapped air. Objectives: To assess the feasibility, safety, and initial outcomes of airway scaffolds in treating emphysema-related hyperinflation. Methods: We conducted a pooled analysis of two first-in-human studies (NCT05949645, NCT05854550) involving patients with heterogeneous or homogeneous emphysema treated bronchoscopically with up to three permanent airway scaffolds per lung. Results: The primary outcome was safety, measured by procedure- and/or device-related serious adverse events over 6 months. Secondary outcomes were technical feasibility, pulmonary function, quality of life, symptoms, exercise capacity at 3 and 6 months, and airway patency assessment by high-resolution computed tomography. Sixty severe emphysema patients (33 female, 27 male; mean age, 66 ± 8 yr; mean residual volume percent predicted, 255 ± 47%) were included. Ninety-eight procedures were performed, and 328 airway scaffolds were successfully placed. A proportion of 21.7% of patients experienced at least one related serious adverse event within 6 months, including pneumonia (10.0%) and chronic obstructive pulmonary disease exacerbation (5.0%), but no pneumothoraxes occurred. Residual volume improved (decreased) from baseline by a mean [95% confidence interval] of 866 [626, 1,106] ml at 3 months and 753 [512, 994] ml at 6 months. Clinically meaningful improvements were further observed in spirometry, quality of life, symptoms, and exercise capacity. Conclusions: This study provides the first clinical evidence of the feasibility, safety, and initial outcomes after treatment with airway scaffolds in patients with emphysema-related hyperinflation.

14 December 2025 in Thorax
Verified
Journal Article
Open access
LCLey Taing Chan
Ley Taing Chan
KLKelvin Kar Wing Lau
Kelvin Kar Wing Lau
COChristopher Michael Orton
Christopher Michael Orton
KTKire Temov
Kire Temov
ATAnand Tana
Anand Tana
PSPallav L Shah
Pallav L Shah
Introduction: Our aim was to evaluate the diagnostic and safety performance of shape-sensing robotic-assisted bronchoscopy (ssRAB) with cone beam CT (CBCT) for the biopsy of pulmonary nodules. Additional analysis was performed to assess outcomes for small nodules and those close to the fissure, pleura or mediastinum. Methods: This single arm, multicentre prospective study enrolled 200 subjects with suspicious pulmonary nodules. Each subject underwent a ssRAB procedure with CBCT and was subsequently followed up. The primary outcome was tool-in-lesion (TIL) confirmed with CBCT. Further endpoints included diagnostic outcomes and rate of adverse events. Results: Of 200 subjects recruited, 198 subjects had a successful biopsy (whereby lesion was reached and sample was taken) and 97% completed the required follow-up. The median size of the nodules was 13 mm; 26.8% (60/224) have a positive bronchus sign and 181 (80.8%) were located in the outer two-thirds of the lung. TIL was obtained in 99.0% (198/200). The strict diagnostic yield was 85% (170/200) with diagnostic accuracy of 92.0% (184/200) and sensitivity for malignancy of 95.5% (147/154). Diagnostic accuracy for nodules under 20 mm size, within 5 mm from a critical structure (eg, heart, aorta or main pulmonary artery) or from the pleura was 88.2% (172/195), 100% (11/11) and 93.3% (56/60), respectively. There were four (2%) serious procedure-related adverse events, with one patient (0.5%) suffering a pneumothorax. Conclusion: ssRAB with CBCT can effectively reach and biopsy small pulmonary nodules, including perifissural, peripleural and paramediastinal lesions with a strong safety profile. Trial registration number: NCT05867953 .