6 October 2021 in Nuclear Fusion
13 April 2021 in Plasma Physics and Controlled Fusion
Reconstructions of plasma equilibria using magnetic sensors were routine during operation of the Mega Ampere Spherical Tokamak (MAST) device, but reconstructions using kinetic profiles were not. These are necessary for stability and disruption analysis of the MAST database, as well as for operation in the upgrade to the device, MAST-U. The three-dimensional (3D) code VALEN is used to determine eddy currents in the 3D vessel structures for vacuum coil test shots, which are then mapped to effective resistances in the two-dimensional vessel groupings in the EFIT equilibrium reconstruction code to be used in conjunction with nearby loop voltage measurements for estimated currents in the structures during reconstruction. Kinetic equilibrium reconstructions with EFIT, using all available magnetic sensors as well as Thomson scattering measurements of electron temperature and density, charge exchange recombination spectroscopy measurements of ion temperature, and internal magnetic field pitch angle measurements from a motional Stark effect (MSE) diagnostic are performed for a large database of MAST discharges. Excellent convergence errors are obtained for the portions of the discharges where the stored energy was not too low, and it is found that reconstructions performed with temperature and density measurements but without MSE data usually already match the pitch angle measurements well. A database of 275 kinetic equilibria is used to test the ideal MHD stability calculation capability for MAST. Finally, the necessary changes to conducting structure in VALEN, and diagnostic setup in EFIT have been completed for the upgrade from MAST to MAST-U, enabling kinetic reconstructions to commence from the first plasma discharges of the upgraded device.
1 September 2017 in Review of Scientific Instruments
Accurate mutual inductances between magnetic diagnostics and poloidal field coils are an essential requirement for determining the poloidal flux for plasma equilibrium reconstruction. The mutual inductance calibration of the flux loops and magnetic probes requires time-varying coil currents, which also simultaneously drive eddy currents in electrically conducting structures. The eddy current-induced field appearing in the magnetic measurements can substantially increase the calibration error in the model if the eddy currents are neglected. In this paper, an expression of the magnetic diagnostic response to the coil currents is used to calibrate the mutual inductances, estimate the conductor time constant, and predict the eddy currents response. It is found that the eddy current effects in magnetic signals can be well-explained by the eddy current response determination. A set of experiments using a specially shaped saddle coil diagnostic are conducted to measure the SUNIST-like eddy current response and to examine the accuracy of this method. In shots that include plasmas, this approach can more accurately determine the plasma-related response in the magnetic signals by eliminating the field due to the eddy currents produced by the external field.
25 February 2020 in Nuclear Fusion
Long-pulse plasma operation at high normalized beta, βN , above the n = 1 ideal MHD no-wall stability limit in KSTAR is presently limited by tearing instabilities rather than resistive wall modes. H-mode plasma operation during the recent KSTAR device campaign produced discharges having strong m/n = 2/1 tearing instabilities at βN lower than the ideal MHD no-wall beta limit. The unstable tearing mode consequently reduced plasma confinement and toroidal plasma rotation significantly. The experiment confirmed that an extended duration of electron cyclotron heating (ECH) at the initial phase of the discharge plays a critical role in mode destabilization. To study destabilizing mechanisms that affect the mode growth, the stability of the observed tearing modes from plasmas with significantly different βN is computed by using the resistive DCON code and the M3D-C1 code employing different physics. The computed tearing stability index, Δ', differs between the mode that is destabilized by the early ECH at lower βN , and the mode that is destabilized at higher βN with observed mode triggering activity. Equilibrium reconstructions that include constraints from internal profile diagnostics are used as input for reliable computation of stability. The modified Rutherford equation (MRE) describing the evolution of the neoclassical tearing mode (NTM) island width has been constructed for KSTAR plasmas by using plasma parameters computed by the TRANSP code. In preparation for long-pulse plasma operation at higher beta utilizing increased plasma heating power, a resistive wall mode (RWM) active feedback control algorithm that includes magnetic sensor compensation of the prompt applied field and the field from the induced current on the passive conductors has been completed and enabled on KSTAR. Use of multiple toroidal sensor arrays is enabled for increased control performance by including the effect of varied mode helicities in the outboard region where the mode measurement is made. This analysis on beta-limiting instabilities and active mode control provides the required foundation for high confinement plasma operation on KSTAR without disruption.
13 November 2024 in Nuclear Fusion
Previous experiments in DIII-D (Paz-Soldan et al 2022 Nucl. Fusion 62 126007) introduced a method to identify intrinsic error fields (EFs) in tokamaks with minimal disruption risk by promptly healing driven magnetic islands during the conventional ‘compass scan’. This paper presents recent experimental and numerical advancements in extending this approach to low q 95 plasmas, and projects its applicability to ITER. Non-disruptive EF measurement is achieved at q 95 = 4.5 and 3.9 without any initial EF correction (EFC) by reducing the time between the occurrence of the locked mode (LM) and control action to 10 ms and increasing the density 50%–100%. However, 50% correction of the intrinsic EF is required to achieve island healing at q 95 = 3.2 with 10 ms delay for the control action. Nonlinear two-fluid modeling with the TM1 code reproduces the DIII-D experimental observations, indicating that promptly turning off the 3D coil current reduces both magnetic island width and electromagnetic force, while raising the density increases plasma viscosity, facilitating magnetic island healing. The simulations show that for scenarios with q 95 = 3.2, lowering the control action time to 5 ms will lead to island healing without EFC. TM1 simulations are extended to future ITER scenarios with 5 MA and 7.5 MA plasma currents, predicting the dependence of required density rise on action time and EF amplitude. These simulations indicate that, benefiting from the much longer resistive time, island healing can be successfully achieved in ITER when taking control action 100–500 ms after a LM occurrence.
3 November 2025 in Plasma Physics and Controlled Fusion
The measurements of the locked mode and other 3D magnetohydrodynamic modes are essential for real-time control of plasma stability in future fusion reactors. Current magnetic measurements present non-negligible challenges for the application on fusion pilot plants (FPPs) due to neutron radiation and pose challenging design issues. In this paper, we discuss an alternative solution with microwave-based measurements. The dual-electron cyclotron emission (ECE) method has been developed and applied on DIII-D. The dual-ECE measurement method demonstrates clear identification of magnetic islands compared to single ECE, which is highly beneficial for locked mode feedback control on the FPPs. Toroidally separated ECE measurements provide accurate three-dimensional structure of magnetic islands and tearing modes. This technique also offers deeper physical insights into the penetration of resonant magnetic perturbations. Numerical calculations indicate that small locked modes (magnetic island width > 2 cm) can be detected using the dual-ECE measurement method in ITER plasma. This will enhance measurement capabilities for the safe operation of FPP plasmas.