Selin Aslan

Selin Aslan

Auto-generated profile, based on publicly available information

Selin Aslan

X-ray Science Division, Argonne National Laboratory, Lemont, IL, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
SASelin Aslan
Selin Aslan
VNViktor Nikitin
Viktor Nikitin
DCDaniel J. Ching
Daniel J. Ching
TBTekin Bicer
Tekin Bicer
SLSven Leyffer
Sven Leyffer
DGDoğa Gürsoy
Doğa Gürsoy
We present the extension of ptychography for three-dimensional object reconstruction in a tomography setting. We describe the alternating direction method of multipliers (ADMM) as a generic reconstruction framework to efficiently solve the nonlinear optimization problem. In this framework, the ADMM breaks the joint reconstruction problem into two well-defined subproblems: ptychographic phase retrieval and tomographic reconstruction. In this paper, we use the gradient descent algorithm to solve both problems and demonstrate the efficiency of the proposed approach through numerical simulations. Further, we show that the proposed joint approach relaxes existing requirements for lateral probe overlap in conventional ptychography. Thus, it can allow more flexible data acquisition.

8 October 2019 in OSA Continuum
Verified
Journal Article
Closed access
PDF file
VNViktor Nikitin
Viktor Nikitin
SASelin Aslan
Selin Aslan
YYYudong Yao
Yudong Yao
TBTekin Biçer
Tekin Biçer
SLSven Leyffer
Sven Leyffer
DGDoğa Gürsoy
Doğa Gürsoy
We introduce a Bayesian framework for the ptychotomographic imaging of 3D objects under photon-limited conditions. This approach is significantly more robust to measurement noise by incorporating prior information on the probabilities of the object features and the measurement process into the reconstruction problem, and it can improve both the temporal and spatial resolution of current and future ptychography instruments. We use the alternating direction method of multipliers to solve the proposed optimization problem, where the ptychography and tomography subproblems are both solved using the conjugate-gradient method. The effectiveness of the framework is demonstrated by reconstructing a synthetic 3D integrated chip with a significantly reduced photon-budget for the simulated experiment.

17 August 2022 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Open access
SMSoumendu Majee
Soumendu Majee
SASelin Aslan
Selin Aslan
DGDoga Gursoy
Doga Gursoy
CBCharles A. Bouman
Charles A. Bouman
In many computed tomography (CT) imaging applications, it is important to rapidly collect data from an object that is moving or changing with time. Tomographic acquisition is generally assumed to be step-and-shoot, where the object is rotated to each desired angle, and a view is taken. However, step-and-shoot acquisition is slow and can waste photons, so in practice fly-scanning is done where the object is continuously rotated while collecting data. However, this can result in motion-blurred views and consequently reconstructions with severe motion artifacts. In this paper, we introduce CodEx, a modular framework for joint de-blurring and tomographic reconstruction that can effectively invert the motion blur introduced in sparse view fly-scanning. The method is a synergistic combination of a novel acquisition method with a novel non-convex Bayesian reconstruction algorithm. CodEx works by encoding the acquisition with a known binary code that the reconstruction algorithm then inverts. Using a well chosen binary code to encode the measurements can improve the accuracy of the inversion process. The CodEx reconstruction method uses the alternating direction method of multipliers (ADMM) to split the inverse problem into iterative deblurring and reconstruction sub-problems, making reconstruction practical to implement. We present reconstruction results on both simulated and binned experimental data to demonstrate the effectiveness of our method.

28 May 2019 in Optics Letters
Verified
Journal Article
Closed access
PDF file
DCDaniel Ching
Daniel Ching
SASelin Aslan
Selin Aslan
VNViktor Nikitin
Viktor Nikitin
DGDoğa Gürsoy
Doğa Gürsoy
We describe a computational imaging system for x-ray tomography, where image capture and post-processing are co-designed to improve final image quality when relative motion of an experiment’s components during a single exposure causes motion blur. The idea is based on temporally encoding the motion during each exposure by fluttering the detector shutter open and closed with a known sequence for guaranteeing an invertible motion blur kernel. While generally applicable, we demonstrate our approach by simulating blurry data acquisition for transmission x-ray tomography and deblurring the reconstructed images. The results suggest that optimized pseudo-random binary time-coded apertures can yield successful reconstructions independent of the size of the blur kernel. This Letter is especially relevant to high-speed x-ray tomography applications where time-resolution is limited by the detector or available photon flux.

30 May 2026 in Journal of Parallel and Distributed Computing
Verified
Journal Article
Closed access
RMRunxuan Miao
Runxuan Miao
SASelin Aslan
Selin Aslan
Erdem KoyuncuErdem Koyuncu
Erdem Koyuncu
DGDoğa Gürsoy
Doğa Gürsoy