The LLC Resonant converter is widely used in on-board charger applications for its high efficiency. However, conventional LLC converter with pulse-frequency-modulation suffers from a wide switching frequency range for realizing constant current (CC) and constant voltage (CV) charges. To address this problem, different from the traditional solution, a novel LCL resonant converter operating at a fixed resonant frequency with inherent CC and CV output characteristics is proposed in this letter. In the proposed concept, the CC and CV charges are accomplished by the special LCL tank. With the increasing of battery voltage during charging process, the resonant tank of the proposed converter is equal to the conventional LCL tank and LC tank for CC mode and CV mode, respectively. Thus, the sensing and control circuits are canceled while the wide zero-voltage-switching operation for primary switches and zero-current-switching for secondary diodes still be maintained. Therefore, the fixed resonant frequency operation, high efficiency, high reliability, and low cost are key features of the proposed converter. A 1-kW prototype with 400 V input and 250–400 V output is built and tested. The full load efficiency of 96.7% and higher than 96% for the CC mode were both achieved. The experimental results demonstrate the advance and validity of the proposed converter.
21 July 2023 in IEEE Transactions on Transportation Electrification
Inductive power transfer (IPT) technology becomes highly attractive option for wireless battery charging applications. To fulfill the charge profile of battery packs, wide output voltage regulation is always necessary. In this paper, an improved LCC-S compensated IPT system utilizing variable frequency switched capacitor control is put forward. Compared with the traditional LCC-S compensation topology, an extra capacitor is connected in series with the compensation inductor to form a symmetrical T-network. Switched capacitor is utilized to regulate the equivalent capacitance of the middle branch of T-network, which has the advantages of low voltage stress. In the proposed control method, the variation range of switching frequency is in compliance with SAE J2954 Standard and frequency bifurcation can be avoided. The detuning issue at receiver side caused by switching frequency variation is solved by using the variable inductor. The proposed IPT system is able to realize nearly unity power factor with high efficiency in the whole voltage range. Finally, a 592 W prototype with 112-168V output voltage is built to verify the proposed IPT system. Experimental results show that the peak efficiency of the improved LCC-S compensated IPT system reaches 94.6% at full load when the coupling coefficient k =0.2.
15 May 2023 in IEEE Transactions on Industrial Electronics
Due to the applied pulse frequency modulation control and switch integration, single-stage boost- LLC ac/dc converters suffer from high bus voltage, which makes them difficult to operate for high voltage input. To solve this issue, a novel single-stage ac/dc converter by incorporating the interleaved discontinuous conduction mode (DCM) boost cell and an LLC cell is proposed. Different from the existing topology, in the proposed converter, two capacitors employed for splitting the ac input voltage into two parts are placed before the rectifier bridge. Thus, the voltage across each power factor correction (PFC) cell is halved and the bus voltage can be significantly reduced. Furthermore, two high-frequency diodes and one filter capacitor are omitted, which helps improve the zero-crossing distortion of the input current. More importantly, the circuit efficiency is thus increased. Hence, low bus voltage, low component count, and high efficiency are the main advantages of the proposed converter. Simulations and experimental results are presented to prove the aforementioned features of the proposed converter.
22 May 2023 in IEEE Transactions on Power Electronics
To address the high bus issue of conventional boost or buck-boost power factor correction (PFC) integrated resonant dc/dc type single-stage converters under high-voltage input, a family of single-stage ac/dc converters integrated interleaved PFC and resonant dc/dc circuits is proposed in this article. Unlike traditional solutions, the ac input voltage of the proposed three interleaved PFC structures is divided into two parts by two capacitors before the rectifier bridge. Thus, two high-frequency power diodes and one filter capacitor are omitted. Furthermore, the reduced bus voltage can be simultaneously obtained with fewer devices. Correspondingly, a better zero-crossing performance of input current can be achieved theoretically. Most importantly, the circuit efficiency also can be increased. Using the common LLC circuit as dc/dc stages, simulations in PSIM are performed to verify the improved zero-crossing of input current. To introduce the proposed converters, the operation principles, design considerations, experimental results, and related comparisons for the proposed structure II with LLC cell are presented comprehensively, achieving at least a 2.3% improvement in efficiency under 220 V nominal input and 100 W load conditions, while maintaining reduced bus voltage and similar PF values. In addition, the experimental results of the topology I and III are also given to prove the validity of the proposed family converters.
13 October 2023 in IEEE Transactions on Power Electronics
To target the 80 Plus 380 Vdc Titanium specifications, this article proposed a novel fixed-frequency isolated dc–dc converter with full-range zero voltage switching (ZVS). Different from the conventional phase-shift full-bridge (PSFB) converter, the series capacitor structure and series-connected two transformers are incorporated in the proposed converter to achieve full-range ZVS operation and light-load efficiency improvement. First, the voltage stress of three primary switches is reduced to half of the input voltage because of the special series capacitor structure. Correspondingly, the energy needed for obtaining the ZVS operation of all primary-side switches is reduced by one-fourth of conventional methods. Furthermore, the employed series-connected two transformers not only achieve the full-range ZVS operation but also eliminate an output inductor presented in conventional PSFB converters. Therefore, higher efficiency can be achieved. In conclusion, low voltage stress, full-range ZVS operation, and fixed switching frequency are the main advantages of the proposed converter. A 360–440 V, 12 V/50 A prototype is built to verify the claimed features of the proposed converter. Experimental waveforms show the ZVS operation under the entire range. The measured efficiency is higher than 95% from 14 A load up to full load, and the peak efficiency of 96.7% can be achieved for 360 V at 25 A load.
14 June 2024 in IEEE Transactions on Power Electronics
Different from the widely used high-voltage (HV) inductive power transfer (IPT) systems, the low-voltage IPT systems with HV input suffer from the following challenges: the high output current brings high conduction losses in the secondary side, especially at the receiver coil; and the HV conversion ratio, such as 400 V input and 24 V output, results in the difficulties in designing the compensation parameters and loosely coupled transformer. To overcome these issues, a novel IPT topology is proposed in this article by incorporating the series-capacitor full-bridge (SCFB) inverter and inverse coupled current doubler rectifier. Thus, the following three improvements are achieved: first, the voltage stress of three primary switches is reduced to half of the input voltage because of the special series capacitor structure. Second, the inherent one-fourth voltage conversion ratio is achieved and reduced greatly the difficulties in designing the compensation parameters. Third, the current flowing through rectifier circuit is reduced to half of conventional full-bridge rectifier. Furthermore, the LC-LCC compensation is employed for matching the proposed SCFB topology while a novel parameter optimization method is proposed to improve the conversion efficiency. To demonstrate the claimed features of the proposed solution, a 1.2 kW IPT prototype with 400 V input, constant voltage 24 V output is built and tested. The measured efficiency curve indicates that the efficiency from 8 to 50 A load keeps above 94.5% and peaks at 96.63%.