George Asimellis

George Asimellis

Auto-generated profile, based on publicly available information

George Asimellis

Laservision.gr Eye Institute, Athens, Greece

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2013 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
JKJohn Kanellopoulos
John Kanellopoulos
GAGeorge Asimellis
George Asimellis
Purpose: To survey the standard keratoconus grading scale (Pentacam®-derived Amsler–Krumeich stages) compared to corneal irregularity indices and best spectacle-corrected distance visual acuity (CDVA). Patients and methods: Two-hundred and twelve keratoconus cases were evaluated for keratoconus grading, anterior surface irregularity indices (measured by Pentacam imaging), and subjective refraction (measured by CDVA). The correlations between CDVA, keratometry, and the Scheimpflug keratoconus grading and the seven anterior surface Pentacam-derived topometric indices – index of surface variance, index of vertical asymmetry, keratoconus index, central keratoconus index, index of height asymmetry, index of height decentration, and index of minimum radius of curvature – were analyzed using paired two-tailed t-tests, coefficient of determination (r2), and trendline linearity. Results: The average ± standard deviation CDVA (expressed decimally) was 0.626 ± 0.244 for all eyes (range 0.10–1.00). The average flat meridian keratometry was (K1) 46.7 ± 5.89 D; the average steep keratometry (K2) was 51.05 ± 6.59 D. The index of surface variance and the index of height decentration had the strongest correlation with topographic keratoconus grading (P< 0.001). CDVA and keratometry correlated poorly with keratoconus severity. Conclusion: It is reported here for the first time that the index of surface variance and the index of height decentration may be the most sensitive and specific criteria in the diagnosis, progression, and surgical follow-up of keratoconus. The classification proposed herein may present a novel benchmark in clinical work and future studies.

1 February 2014 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
AKAnastasios John Kanellopoulos
Anastasios John Kanellopoulos
GAGeorge Asimellis
George Asimellis
PURPOSE: To investigate refractive, topometric, pachymetric, and visual rehabilitation changes induced by anterior surface normalization for keratoconus by partial topography-guided excimer laser ablation in conjunction with accelerated, high-fluence cross-linking. METHODS: Two hundred thirty-one keratoconic cases subjected to the Athens Protocol procedure were studied for visual acuity, keratometry, pachymetry, and anterior surface irregularity indices up to 3 years postoperatively by Scheimpflug imaging (Oculus Optikgeräte GmbH, Wetzlar, Germany). RESULTS: Mean visual acuity changes at 3 years postoperatively were +0.38 ± 0.31 (range: −0.34 to +1.10) for uncorrected distance visual acuity and +0.20 ± 0.21 (range: −0.32 to +0.90) for corrected distance visual acuity. Mean K1 (flat meridian) keratometric values were 46.56 ± 3.83 diopters (D) (range: 39.75 to 58.30 D) preoperatively, 44.44 ± 3.97 D (range: 36.10 to 55.50 D) 1 month postoperatively, and 43.22 ± 3.80 D (range: 36.00 to 53.70 D) up to 3 years postoperatively. The average Index of Surface Variance was 98.48 ± 43.47 (range: 17 to 208) pre-operatively and 76.80 ± 38.41 (range: 7 to 190) up to 3 years postoperatively. The average Index of Height Decentration was 0.091 ± 0.053 μ m (range: 0.006 to 0.275 μ m) preoperatively and 0.057 ± 0.040 μ m (range: 0.001 to 0.208 μ m) up to 3 years postoperatively. Mean thinnest corneal thickness was 451.91 ± 40.02 μ m (range: 297 to 547 μ m) preoperatively, 353.95 ± 53.90 μ m (range: 196 to 480 μ m) 1 month postoperatively, and 370.52 ± 58.21 μ m (range: 218 to 500 μ m) up to 3 years postoperatively. CONCLUSIONS: The Athens Protocol to arrest keratectasia progression and improve corneal regularity demonstrates safe and effective results as a keratoconus management option. Progressive potential for long-term flattening validates using caution in the surface normalization to avoid overcorrection. [ J Refract Surg. 2014;30(2):88–92.]

1 January 2014 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
AKAnastasios John Kanellopoulos
Anastasios John Kanellopoulos
GAGeorge Asimellis
George Asimellis

1 June 2001 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
SRS Rosenwasser
S Rosenwasser
GAG Asimellis
G Asimellis
BBB Bromley
B Bromley
RHR Hazlett
R Hazlett
JMJ Martin
J Martin
AZA Zigler
A Zigler

1 November 2013 in Cornea
Verified
Journal Article
Closed access
AKAnastasios John Kanellopoulos
Anastasios John Kanellopoulos
GAGeorge Asimellis
George Asimellis
To evaluate the safety and efficacy of real-time measurement of corneal epithelial thickness and investigate the distribution characteristics in a large normal-eye population using a clinically available spectral-domain anterior-segment optical coherence tomography (AS OCT) system. Corneal epithelial thickness distribution and topographic thickness variability were clinically investigated using AS OCT imaging in 373 patients with normal, healthy eyes. Descriptive statistics investigated 3 sets of subgroups, male (n = 171) and female (n = 202), younger (n = 194) and older (n = 179), right eyes (n = 195) and left eyes (n = 197). Pupil center epithelial thickness repeatability was an average 0.88 ± 0.71 μm; a similar repeatability was noted for the superior, inferior, maximum, and minimum epithelial thickness. On average, the pupil center epithelial thickness was 53.28 ± 3.34 μm, superior 51.86 ± 3.78 μm, inferior 53.81 ± 3.44 μm, minimum 48.65 ± 4.54 μm, maximum 56.35 ± 3.80 μm, and topographic variability was 1.78 ± 0.78 μm. Small differences were noted between male (average center 54.10 ± 3.34 μm) and female (52.58 ± 3.19 μm) subjects. The topographic thickness variability seems to increase with age: younger group, 1.65 ± 0.83 μm; older group, 1.93 ± 0.90 μm (P = 0.173). We present a comprehensive investigation of corneal epithelial thickness distribution characteristics in a healthy, untreated human eye population by using in vivo, clinically available Fourier-domain AS OCT. The 3-dimensional epithelial maps reveal epithelial nonuniformity and provide a novel benchmark for future and comparative studies.

1 May 2012 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
JKJohn Kanellopoulos
John Kanellopoulos
IAIoannis M Aslanides
Ioannis M Aslanides
ASAsimelis
Asimelis
GAGeorge Asimellis
George Asimellis
Purpose: To determine and correlate epithelial corneal thickness (pachymetric) measurements taken with a digital arc scanning very high frequency ultrasound biomicroscopy (HF UBM) imaging system (Artemis-II), and compare mean and central epithelial thickness among normal eyes, untreated keratoconic eyes, and keratoconic eyes previously treated with collagen crosslinking (CXL). Methods: Epithelial pachymetry measurements (topographic mapping) were conducted on 100 subjects via HF UBM. Three groups of patients were included: patients with normal eyes (controls), patients with untreated keratoconic eyes, and patients with keratoconic eyes treated with CXL. Central, mean, and peripheral corneal epithelial thickness was examined for each group, and a statistical study was conducted. Results: Mean, central, and peripheral corneal epithelial thickness was compared between the three groups of patients. Epithelium thickness varied substantially in the keratoconic group, and in some cases there was a difference of up to 20 µm between various points of the same eye, and often a thinner epithelium coincided with a thinner cornea. However, on average, data from the keratoconic group suggested an overall thickening of the epithelium, particularly over the pupil center of the order of +3 µm, while the mean epithelium thickness was on average +1.1 µm, compared to the control population (P = 0.005). This overall thickening was more pronounced in younger patients in the keratoconic group. Keratoconic eyes previously treated with CXL showed, on average, virtually the same average epithelium thickness (mean –0.7 µm, –0.2 µm over the pupil center, –0.9 µm over the peripheral zone) as the control group. This finding further reinforces our novel theory of the “reactive” component of epithelial thickening in corneas that are biomechanically unstable, becoming stable when biomechanical rigidity is accomplished despite persistence of cornea topographic irregularity. Conclusion: A highly irregular epithelium may be suggestive of an ectatic cornea. Our results indicate that the epithelium is thinner over the keratoconic protrusion, but to a much lesser extent than anticipated, and on average epithelium is thicker in this group of patients. This difference appears to be clinically significant and may become a screening tool for eyes suspected for ectasia.