Martyn N.J. Paley

Martyn N.J. Paley

Auto-generated profile, based on publicly available information

Martyn N.J. Paley

Academic Unit of Radiology, Department of Infection, Immunity and Cardiovascular Disease The Medical School, University of Sheffield Sheffield UK

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2005 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
NWNeil Woodhouse
Neil Woodhouse
JWJim M. Wild
Jim M. Wild
MPMartyn N.J. Paley
Martyn N.J. Paley
SFStanislao Fichele
Stanislao Fichele
ZSZead Said
Zead Said
EBEdwin J.R. van Beek
Edwin J.R. van Beek
Purpose: To use a combination of helium‐3 (3‐He) magnetic resonance imaging (MRI) and proton single‐shot fast spin echo (SSFSE) to compare ventilated lung volumes in groups of “healthy” smokers, smokers diagnosed with moderate chronic obstructive pulmonary disease (COPD), and never‐smokers.Materials and Methods: All study participants were assessed with spirometry prior to imaging. 3‐He images were collected during an arrested breath hold, after inhaling a mixture of 200 mL of hyperpolarized 3‐He/800 mL of N2. Proton SSFSE images were acquired after inhaling 1 liter of room air. The ventilated volume for each study participant was calculated from the 3‐He images, and a ratio was calculated to give a percentage ventilated lung volume.Results: Never‐smokers exhibited a 90% mean ventilated volume. The mean ventilated lung volumes for healthy smokers and smokers diagnosed with COPD were 75.2% and 67.6%, respectively. No correlation with spirometry was demonstrated for either of the smoking groups.Conclusion: Combined 3‐He/Proton SSFSE MRI of the lungs is a noninvasive method, using nonionizing radiation, which demonstrates ventilated airspaces and enables the calculation of ventilated lung volumes. This method appears to be sensitive to early obstructive changes in the lungs of smokers. J. Magn. Reson. Imaging 2005;21:365–369.

28 November 2021 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
SRSteven Reynolds
Steven Reynolds
SKSamira M. Kazan
Samira M. Kazan
AAAdriana Anton
Adriana Anton
TATooba Alizadeh
Tooba Alizadeh
RGRoger N. Gunn
Roger N. Gunn
VCVincent J. Cunningham
Vincent J. Cunningham
Dissolution dynamic nuclear polarisation (dDNP) of 13C‐labelled pyruvate in magnetic resonance spectroscopy/imaging (MRS/MRSI) has the potential for monitoring tumour progression and treatment response. Pyruvate delivery, its metabolism to lactate and efflux were investigated in rat P22 sarcomas following simultaneous intravenous administration of hyperpolarised 13C‐labelled pyruvate (13C1‐pyruvate) and urea (13C‐urea), a nonmetabolised marker. A general mathematical model of pyruvate‐lactate exchange, incorporating an arterial input function (AIF), enabled the losses of pyruvate and lactate from tumour to be estimated, in addition to the clearance rate of pyruvate signal from blood into tumour, Kip, and the forward and reverse fractional rate constants for pyruvate‐lactate signal exchange, kpl and klp. An analogous model was developed for urea, enabling estimation of urea tumour losses and the blood clearance parameter, Kiu. A spectral fitting procedure to blood time‐course data proved superior to assuming a gamma‐variate form for the AIFs. Mean arterial blood pressure marginally correlated with clearance rates. Kiu equalled Kip, indicating equivalent permeability of the tumour vasculature to urea and pyruvate. Fractional loss rate constants due to effluxes of pyruvate, lactate and urea from tumour tissue into blood (kpo, klo and kuo, respectively) indicated that T1s and the average flip angle, θ, obtained from arterial blood were poor surrogates for these parameters in tumour tissue. A precursor‐product model, using the tumour pyruvate signal time‐course as the input for the corresponding lactate signal time‐course, was modified to account for the observed delay between them. The corresponding fractional rate constant, kavail, most likely reflected heterogeneous tumour microcirculation. Loss parameters, estimated from this model with different TRs, provided a lower limit on the estimates of tumour T1 for lactate and urea. The results do not support use of hyperpolarised urea for providing information on the tumour microcirculation over and above what can be obtained from pyruvate alone. The results also highlight the need for rigorous processes controlling signal quantitation, if absolute estimations of biological parameters are required.