Keiichiro Yoshida

Keiichiro Yoshida

Auto-generated profile, based on publicly available information

Keiichiro Yoshida

Mechanical Engineering, Osaka Prefecture University, Osaka, JAPAN

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2012 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
TKTakuya Kuwahara
Takuya Kuwahara
KYKeiichiro Yoshida
Keiichiro Yoshida
KHKenichi Hanamoto
Kenichi Hanamoto
KSKazutoshi Sato
Kazutoshi Sato
TKTomoyuki Kuroki
Tomoyuki Kuroki
Masaaki OkuboMasaaki Okubo
Masaaki Okubo
As the regulations governing diesel engine emissions have become more stringent, it has become difficult to fulfill these new requirements by only using techniques that improve combustion. Therefore, more effective aftertreatment technology is needed, particularly for particulate matter. Although ceramic diesel particulate filter (DPF) is a leading technology in automobiles, their implementation in marine diesel engines operated with marine diesel oil (A-heavy fuel oil) containing sulfur presents a problem, in terms of soot removal or regeneration. In this study, a pilot-scale experiment is performed to establish a method implementing nonthermal-plasma-induced radicals for DPF regeneration of marine diesel engines. The pressure difference decreases only when plasma is turned on, and DPF regeneration is realized at 320 °C. The amount of ozone required for regeneration is determined under various engine operating conditions, and the basic characteristics of regeneration are elucidated. The plasma energy required for emission control of the entire gas is approximately 5% of the generated power of the marine engine.

22 June 2012 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
KYKeiichiro Yoshida
Keiichiro Yoshida
TKTakuya Kuwahara
Takuya Kuwahara
TKTomoyuki Kuroki
Tomoyuki Kuroki
MOMasaaki Okubo
Masaaki Okubo

1 January 2008 in The Proceedings of the Symposium on Environmental Engineering
Verified
Journal Article
Closed access
PDF file
TKTomoyuki Kuroki
Tomoyuki Kuroki
HFHidekatsu Fujishima
Hidekatsu Fujishima
KOKeiichi Otsuka
Keiichi Otsuka
TITomohito Ito
Tomohito Ito
ATAtsumi Tatsumi
Atsumi Tatsumi
KYKeiichiro Yoshida
Keiichiro Yoshida
Continuous operation tests of the boiler emission treatment plant which consists of a commercial ozonizer for indirect NO oxidation and a Na_2SO_3 chemical scrubber are carried out for gas firing and heavy oil boilers. For gas firing boiler emission, the NO complete removal and the decrease in NO_x from 32 ppm to 3 ppm are achieved. This performance is maintained for 300 min by keeping -30 mV of oxidation-reduction potential (ORP) of circulating solution in the chemical scrubber. Concerning the treatment of heavy oil boiler emission, the decrease in NO_x from 90 ppm to less than 25 ppm is maintained for 250 min by keeping -30 mV of ORP. However, the unreacted NO of 15 ppm is detected at a scrubber outlet because the O_3 for NO oxidation is inadequate. By sufficient O_3 injection for NO oxidation, NO_x removal efficiency can be improved.

1 January 2007 in The Proceedings of the Symposium on Environmental Engineering
Verified
Journal Article
Closed access
PDF file
KYKeiichiro Yoshida
Keiichiro Yoshida
Masaaki OkuboMasaaki Okubo
Masaaki Okubo
TKTomoyuki Kuroki
Tomoyuki Kuroki
TYToshiaki Yamamoto
Toshiaki Yamamoto
In our previous studies, a novel NO_x aftertreatment system using adsorption and reduction by nonthermal plasma desorption is proposed. In the present study, application of the system to a real stationary diesel engine generator is investigated. The NO_x is first removed by adsorption, then the adsorbent is regenerated by thermal desorption using waste heat of the exhaust gas. In the regeneration process, hot exhaust gas passes through the heat exchanger tubes surrounded by the adsorbent pellets. The desorbed NO_x is subsequently reduced to N_2 by nitrogen nonthermal plasma. This system reduces 245〜270ppm NO_x emitted by the generator to around 50% for 8 hours.

1 January 2011 in The Proceedings of the Symposium on Environmental Engineering
Verified
Journal Article
Closed access
PDF file
Masaaki OkuboMasaaki Okubo
Masaaki Okubo
TKTakuya Kuwahara
Takuya Kuwahara
MNMasafumi Nishimoto
Masafumi Nishimoto
TKTomoyuki Kuroki
Tomoyuki Kuroki
KYKeiichiro Yoshida
Keiichiro Yoshida
The authors realize a new prototype of plasma-assisted environmental protection aftertreatment system using atmospheric-pressure nonthermal plasma combine processes for super clean diesel engines. This system does not use any rare or precious metal catalysts and harmful ammonia or urea solution. A NOx aftertreatment system, using nonthermal plasma (NTP) reduction and exhaust gas components recirculation, is investigated. A pilot-scale system is applied to a stationary diesel engine using A type of heavy oil fuel. In this system, NOx is first removed by adsorption, and subsequently, the adsorbent is regenerated by thermal desorption. The desorbed high-concentration NOx is reduced by using nitrogen NTP with low flow rate. Moreover, NOx re-circulated into the engine intake reduces NOx emission. In the present experiments, a very high system energy efficiency of 437 g (NO_2)/kWh is achieved in the NOx reduction test. The developed system demonstrates excellent energy efficiencies to meet the most recent international regulation of marine diesel engine exhaust gas.

1 January 2006 in The Proceedings of the Symposium on Environmental Engineering
Verified
Journal Article
Closed access
PDF file
Masaaki OkuboMasaaki Okubo
Masaaki Okubo
AKAkinori Kajimoto
Akinori Kajimoto
TKTomoyuki Kuroki
Tomoyuki Kuroki
KYKeiichiro Yoshida
Keiichiro Yoshida
TYToshiaki Yamamoto
Toshiaki Yamamoto
The ozonizer combined with the chemical hybrid reactor is investigated using a 479cc (5.5kW) power generation diesel engine. The PM deposited on the diesel particulate filter can be incinerated by ozone and NO_2 and evaluated for various gas temperatures. The NO is oxidized to form NO_2 by ozone and produced NO_2 is reduced by the 3 mass% Na_2SO_3 chemical reactor. Furthermore, a new ozone circulation system for DPF regeneration is proposed. As the results, PM deposited on both metal and ceramic filters are successfully removed even at ambient temperature. With the use of 10L/min with 2% ozone concentration, 82% of NO is oxidized to NO_2 and 78% of NO_x is removed. The operating cost is approximately 25% of the conventional SCR.