Kiyo T. Fujimoto

Kiyo T. Fujimoto

Auto-generated profile, based on publicly available information

Kiyo T. Fujimoto

Idaho National Laboratory (INL), Idaho Falls, ID (United States)

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2020 in npj Flexible Electronics
Verified
Journal Article
Open access
PDF file
KFKiyo T. Fujimoto
Kiyo T. Fujimoto
JWJennifer K. Watkins
Jennifer K. Watkins
TPTimothy Phero
Timothy Phero
DLDoug Litteken
Doug Litteken
KTKevin Tsai
Kevin Tsai
DEDavid Estrada
David Estrada
Soft structural textiles, or softgoods, are used within the space industry for inflatable habitats, parachutes and decelerator systems. Evaluating the safety and structural integrity of these systems occurs through structural health monitoring systems (SHM), which integrate non-invasive/non-destructive testing methods to detect, diagnose, and locate damage. Strain/load monitoring of these systems is limited while utilizing traditional strain gauges as these gauges are typically stiff, operate at low temperatures, and fail when subjected to high strain that is a result of high loading classifying them as unsuitable for SHM of soft structural textiles. For this work, a capacitance based strain gauge (CSG) was fabricated via aerosol jet printing (AJP) using silver nanoparticle ink on a flexible polymer substrate. Printed strain gauges were then compared to a commercially available high elongation resistance-based strain gauge (HE-RSG) for their ability to monitor strained Kevlar straps having a 26.7 kN (6 klbf) load. Dynamic, static and cyclic loads were used to characterize both types of strain monitoring devices. Printed CSGs demonstrated superior performance for high elongation strain measurements when compared to commonly used HE-RSGs, and were observed to operate with a gauge factor of 5.2 when the electrode arrangement was perpendicular to the direction of strain.

2 June 2025 in Nano Energy
Verified
Journal Article
Open access
APAjay Pratap
Ajay Pratap
FKFereshteh Rajabi Kouchi
Fereshteh Rajabi Kouchi
HBHailey Burgoyne
Hailey Burgoyne
MCMichael Curtis
Michael Curtis
ARAttila Rektor
Attila Rektor
DEDavid Estrada
David Estrada

23 August 2021
Verified
Report
Closed access
MWMalwina Wilding
Malwina Wilding
Kunal MondalKunal Mondal
Kunal Mondal
KFKiyo Fujimoto
Kiyo Fujimoto
RLRandy Lloyd
Randy Lloyd
MMMichael McMurtrey
Michael McMurtrey
TUTroy Unruh
Troy Unruh
As a part of the In-Pile Instrumentation Program, The Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced manufactured sensors for measuring the peak irradiation temperature inside a nuclear test reactor. Although nuclear test reactors can use standard methods of real-time temperature monitoring, such as thermocouples, the complexity of feedthroughs and attachment complications to collect real-time measurements greatly increases the cost of the experiment. Passive monitoring techniques may be utilized that exploit the melting point of well characterized material (standard melt wires), however, the limited space available for instrumentation during experiments is also a challenge. To accommodate the challenge, INL has expanded its temperature detection instrumentation capabilities paired with the advancement of in-house advanced manufacturing options to include printed melt wires for peak irradiation temperature measurement. The advanced manufactured melt wire package can determine peak temperatures in experiments that can fit the challenging space available during irradiation. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing. This report summarizes the initial temperature testing using fabricated melt wires with two different melting temperatures, silver (melting temperature of ~960 oC) and solder (melting temperature of ~160 oC), that were initially tested for their relative melting points using non-standard method of furnace and hot plate testing under normal air conditions. Future work will include more controlled way of testing printed melt wires under inert gas with multiple temperature measurements followed by comparison of standard melt wire package performance for baseline characterization.


1 July 2021
Verified
Report
Closed access
PDF file
Amey KhanolkarAmey Khanolkar
Amey Khanolkar
KFKiyo T Fujimoto
Kiyo T Fujimoto
MMMichael D McMurtrey
Michael D McMurtrey
As part of the advanced manufacturing (AM) focus of the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) Program, new in-house capabilities to fabricate and test novel active and passive in-pile sensors are being developed at the Idaho National Laboratory (INL). These advanced-manufactured sensors, such as peak temperature monitors and strain gauges, must be miniaturized and be able to provide real-time feedback, all while withstanding the coupled extremes of temperature and radiation typically observed in the environment of a nuclear test reactor. Fabricating durable and robust in-pile sensors with high fidelity requires a fundamental understanding of the optimal process parameters required in the AM technique, as well as the effect of deviations from optimal process parameters on the sensor-substrate adhesion and the ultimate robustness of the sensor. This report presents the use of a laser-based, non-contact approach for characterizing the adhesion of sensors manufactured using aerosol jet printing (AJP) that comprise of silver nanoparticle inks deposited and sintered on austenitic stainless steel (SS) 316L substrates. The effect of substrate surface roughness, surface energy, ink sintering time and sintering temperature on the printed sensor topography and the sensor-substrate adhesion has been systematically investigated. The sensor-substrate interfacial adhesion strength wasmore » determined from the critical laser pulse energy required to ablate/ detach the printed sensor from the substrate. Measurements of the sensor topography using optical profilometry revealed that post-deposition sintering at 400°C for 60 minutes resulted in a reduced sensor thickness, while plasma treating the substrate prior to printing yielded sensors with uniform thickness profiles transverse to the print direction. Sintering temperature and time were found to be the dominant parameters that affected sensor-substrate adhesion, followed by substrate surface roughness. The laser-based and locally-destructive approach for adhesion strength measurements shows promise in overcoming the challenges and limitations of current standardized peel tests and can be developed into a post-fabrication process control protocol for evaluating the durability of AM printed sensors in a high throughput fashion. Future studies will investigate the use of laser-induced spallation techniques as well as non-destructive laser ultrasonic methods for sensor-substrate adhesion characterization on sensors manufactured using AJP and other AM techniques such as plasma jet printing (PJP). « less

1 October 2022
Verified
Report
Open access
PDF file
TPTimothy Phero
Timothy Phero
Amey KhanolkarAmey Khanolkar
Amey Khanolkar
KFKiyo T Fujimoto
Kiyo T Fujimoto
JSJames Smith
James Smith
MMMichael D McMurtrey
Michael D McMurtrey
The successful adoption of additive manufacturing for the rapid prototyping of printed sensors requires the establishment of quantifiable metrics that can interrogate device performance. One measure of performance is the adhesion strength between the substrate and sensor interface, which is critical since the strength of this interface can dictate the accuracy and reliability of the printed sensor. In this work, a non-contact laser-induced spallation technique was used to quantify the adhesion of silver prints on an aluminum alloy substrate. The laser-based method was compared to a standardized pull-off adhesion test, which provided baseline measurements of adhesion strength. The sintering conditions were shown to play an important role in the film-substrate adhesion strength, as well as the cohesion and ductility of the film itself. The methods and results described in this work supports the establishment of process control steps that are necessary for verifying the reliability of printed devices prior to its deployment in critical experiments.