Bianca Güttner

Bianca Güttner

Auto-generated profile, based on publicly available information

Bianca Güttner

Department of Translational Surgical Oncology, National Center for Tumor Diseases (NCT), NCT/UCC Dresden, a partnership between DKFZ, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, and Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Dresden, Germany.

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2024 in Medical Image Analysis
Verified
Journal Article
Open access
Sharib AliSharib Ali
Sharib Ali
YEYamid Espinel
Yamid Espinel
YJYueming Jin
Yueming Jin
PLPeng Liu
Peng Liu
BGBianca Güttner
Bianca Güttner
ABAdrien Bartoli
Adrien Bartoli
Augmented reality for laparoscopic liver resection is a visualisation mode that allows a surgeon to localise tumours and vessels embedded within the liver by projecting them on top of a laparoscopic image. Preoperative 3D models extracted from Computed Tomography (CT) or Magnetic Resonance (MR) imaging data are registered to the intraoperative laparoscopic images during this process. Regarding 3D-2D fusion, most algorithms use anatomical landmarks to guide registration, such as the liver's inferior ridge, the falciform ligament, and the occluding contours. These are usually marked by hand in both the laparoscopic image and the 3D model, which is time-consuming and prone to error. Therefore, there is a need to automate this process so that augmented reality can be used effectively in the operating room. We present the Preoperative-to-Intraoperative Laparoscopic Fusion challenge (P2ILF), held during the Medical Image Computing and Computer Assisted Intervention (MICCAI 2022) conference, which investigates the possibilities of detecting these landmarks automatically and using them in registration. The challenge was divided into two tasks: (1) A 2D and 3D landmark segmentation task and (2) a 3D-2D registration task. The teams were provided with training data consisting of 167 laparoscopic images and 9 preoperative 3D models from 9 patients, with the corresponding 2D and 3D landmark annotations. A total of 6 teams from 4 countries participated in the challenge, whose results were assessed for each task independently. All the teams proposed deep learning-based methods for the 2D and 3D landmark segmentation tasks and differentiable rendering-based methods for the registration task. The proposed methods were evaluated on 16 test images and 2 preoperative 3D models from 2 patients. In Task 1, the teams were able to segment most of the 2D landmarks, while the 3D landmarks showed to be more challenging to segment. In Task 2, only one team obtained acceptable qualitative and quantitative registration results. Based on the experimental outcomes, we propose three key hypotheses that determine current limitations and future directions for research in this domain.

26 May 2026 in Medical Image Analysis
Verified
Journal Article
Open access
PLPeng Liu
Peng Liu
BGBianca Güttner
Bianca Güttner
YSYutong Su
Yutong Su
CLChenyang Li
Chenyang Li
JXJinjing Xu
Jinjing Xu
MPMicha Pfeiffer
Micha Pfeiffer
Non-rigid registration is essential for augmented reality-guided laparoscopic liver surgery, as it enables the fusion of preoperative information such as tumor location and vascular structures into the limited intraoperative view, thereby enhancing surgical navigation. A prerequisite is the accurate prediction of intraoperative liver deformation, which remains highly challenging due to factors such as large deformation caused by pneumoperitoneum, respiration and tool interaction as well as noisy intraoperative data, and limited field of view due to occlusion and constrained camera movement. To address these challenges, we introduce PIVOTS, a Preoperative to Intraoperative VOlume-To-Surface registration neural network that directly takes point clouds as input for deformation prediction. The geometric feature extraction encoder allows multi-resolution feature extraction, and the decoder, comprising inter-modality cross attention modules, enables information exchange between pre- and intraoperative features and accurate multi-level displacement prediction. We train the neural network on a large synthetic dataset created using a biomechanical simulation pipeline that explicitly targets the mentioned intraoperative challenges and validate its performance on both synthetic and real datasets. Results demonstrate superior registration performance of our method compared to baseline methods, exhibiting strong robustness against high amounts of noise, large deformation, and various levels of intraoperative visibility. The network is fast enough to run multiple times per second and directly generalizes to new patients without retraining. We publish training and test sets as evaluation benchmarks in an effort to contribute to the development of more robust liver registration methods based on volume-to-surface data. Code, docker container and datasets are available athttps://github.com/pengliu-nct/PIVOTS.

2 July 2026 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
BGBianca Güttner
Bianca Güttner
MPMicha Pfeiffer
Micha Pfeiffer
SSStefanie Speidel
Stefanie Speidel
Purpose: Commonly used accuracy metrics for non-rigid registration such as target registration error (TRE) do not assess the mechanical plausibility of predicted deformations. We introduce a metric to quantify local coherence of deformation and complement existing measures of physical validity. Methods: We propose the strain alignment metric, which evaluates local directional consistency of deformation by analyzing the principal directions and magnitudes of the Green strain tensor. The metric combines three components: (i) a sign term penalizing local flips between compression and extension, (ii) a magnitude term capturing relative variation in principal strain magnitude within a neighborhood and (iii) an angular term measuring non-directional alignment of principal strain directions. The metric is computed locally and summarized over the mesh. We compare it to the Jacobian determinant and strain norm on synthetic liver deformations registered using a deep learning-based method and a fast biomechanical FEM approach. Results: While both methods achieve comparable TRE, the proposed metric captures substantial differences in deformation coherence on the sample level that the Jacobian determinant and strain norm only show upon single mesh inspection. It is able to clearly differentiate the largely coherent deformation despite volume changes of the biomechanical method from the local inconsistencies of the learning-based method, including alternating compression and extension patterns. Conclusion: Strain alignment provides complementary, interpretable information about the mechanical plausibility of predicted displacement fields. It enables quantitative assessment of local deformation coherence without requiring material assumptions and further highlights limitations of accuracy-only evaluation in non-rigid registration.