Wanchak Lenwari

Wanchak Lenwari

Auto-generated profile, based on publicly available information

Wanchak Lenwari

Faculty of Engineering, KMUTT,Embedded Computing and Control Laboratory

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
WGWarda Gul
Warda Gul
QGQiang Gao
Qiang Gao
WLWanchak Lenwari
Wanchak Lenwari

7 April 2009 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WLWanchak Lenwari
Wanchak Lenwari
MSMark Sumner
Mark Sumner
PZPericle Zanchetta
Pericle Zanchetta
Resonant compensators appear to be suitable for active power filter control, where the compensator needs to track harmonic currents accurately. However, to ensure stable operation and robustness to parameter uncertainties they require considerable design effort. This paper describes the use of a genetic algorithm for the optimization of the parameters of a resonant controller employed for the control of current in a shunt active filter. The optimization process takes into account variations of the power system parameters to provide an optimum solution in terms of both speed of response and robustness. Experimental results confirm the effectiveness to the approach.

1 November 2009
Verified
Conference Paper
Closed access
WLWanchak Lenwari
Wanchak Lenwari
MOMilijana Odavic
Milijana Odavic
In recent years, the increase of non-linear loads in electrical power system has sparked the research in power quality issue. The shunt active power filter (SAPF) is a power electronic device which has been developed to improve power quality. The current control of shunt power filters is critical since poor control can reinforce existing harmonic problems. Various control strategies have been proposed by many researchers. In this paper, a comparative evaluation of the performance of two current control techniques, resonant and predictive controller, is presented with identical system specification. The design procedure and principle of both current control methods are also presented in detail. Simulation results show the comparison of transient response, steady state control and performance in the presence of variation of supply impedance between two control techniques.

1 November 2006 in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
Verified
Conference Paper
Closed access
WLWanchak Lenwari
Wanchak Lenwari
MSMark Sumner
Mark Sumner
PZPericle Zanchetta
Pericle Zanchetta
MCMihai Culea
Mihai Culea
This paper proposes a very accurate harmonic current control for shunt active filters (SAF) using resonant compensators. The resonant control compensator based on sinusoidal internal model principle is introduced into the control system design in order to improve the control accuracy and performance for ac input signal. The proposed current control system is designed to operate with a single dq reference frame, synchronous with the 50 Hz supply voltage, for the compensation of all main harmonic currents, 5th, 7th, 11th and 13th. The principle of the proposed control method and the design procedure is presented. Experimental results confirm the accuracy and effectiveness of the suggested approach. Excellent harmonic current tracking performance can be achieved. Another major advantage of this strategy is the ability to eliminate the effect of an ac external disturbance from the harmonic components caused by the power supply

1 February 2013
Verified
Conference Paper
Closed access
WLWanchak Lenwari
Wanchak Lenwari
With the recent advances in power electronic technology, the increase of non-linear loads such as power converters has deteriorated power quality and sparked the research in power quality issue. Shunt Active filter(SAF) is a power electronic device developed to improve power quality. Proportional-resonant(PR) type controller appears to be appropriate for the control system in active filters, where the precise tracking performance of harmonic currents is required. However, due to the complexity of the controller structure, to obtain suitable controller parameters, it requires considerable design effort in particular for a non-expert. This paper presents an automated design procedure to optimize a modified proportional-multiple resonant controller for the compensation of all main order harmonics, the 5th, 7th, 11th, 13th, 17th and 19th harmonics. The principle of the proposed control method and the optimization procedure based on genetic algorithms are described in detail. The excellent control performance has been carried out by simulations.