Dilson Amancio Alves

Dilson Amancio Alves

Auto-generated profile, based on publicly available information

Dilson Amancio Alves

So Paulo State University,FEE/FEIS-UNESP,Ilha Solteira,Brazil

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2023
Verified
Conference Paper
Closed access
Alfredo Bonini NetoAlfredo Bonini Neto
Alfredo Bonini Neto
WSWesley Prado Leão dos Santos
Wesley Prado Leão dos Santos
DADilson Amancio Alves
Dilson Amancio Alves
CMCarlos Roberto Minussi
Carlos Roberto Minussi
This work presents the application of an artificial neural network to estimate the total real power losses of an electrical power system. The network used is the Multilayer Perceptron composed of 3 neurons in the input layer (loading factor, real and reactive power generated in the slack bus), 10 neurons in the intermediate layer and 1 neuron in the output layer, representing the total real power losses. The training used is the backpropagation, which uses the desired output (target) to adjust the weights. From the results (IEEE systems of 14 and 30 buses), the network performed well, with mean squared error around 10 -4 , and R-value at 0.99. For validation and testing, with 20% of samples, the network proved to be efficient, with MSE also around 10 -4 . In this context, the network was able to estimate the total real power losses in function of loading, showing that the obtained output was very close to the one desired.

22 November 2023
Verified
Conference Paper
Closed access
Alfredo Bonini NetoAlfredo Bonini Neto
Alfredo Bonini Neto
WSWesley Prado Leão dos Santos
Wesley Prado Leão dos Santos
DADilson Amancio Alves
Dilson Amancio Alves
CMCarlos Roberto Minussi
Carlos Roberto Minussi
This paper presents the features of proposed methods that allow the tracing of the P-V curves. With small modifications it becomes possible to use the traditional methods such as the Newton's method, that makes use of the Jacobian matrix, which becomes singular in the maximum loading point (nose point); and of the standard fast decoupled load flow (version XB and BX), believed not to be adapted for the computation of the points below and near the point of maximum loading. These methods are compared to each other with the purpose of pointing out its features. The results obtained for the IEEE systems (14, 30, 57 and 118 buses) are also compared with the ones of a continuation power flow method and of an optimal power flow. It was observed that in all the methods tested the maximum loading points found were always the same.