Byungdo Park

Byungdo Park

Auto-generated profile, based on publicly available information

Byungdo Park

Gyeongsang National University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
GAG. Acampora
G. Acampora
CAC. Ahdida
C. Ahdida
RARaffaele Albanese
Raffaele Albanese
CAC. Albrecht
C. Albrecht
AAAndrey Alexandrov
Andrey Alexandrov
TCThe Snd@Lhc Collaboration
The Snd@Lhc Collaboration
SND@LHC is a compact and stand-alone experiment designed to perform measurements with neutrinos produced at the LHC in the pseudo-rapidity region of 7.2 < η < 8.4. The experiment is located 480 m downstream of the ATLAS interaction point, in the TI18 tunnel. The detector is composed of a hybrid system based on an 830 kg target made of tungsten plates, interleaved with emulsion and electronic trackers, also acting as an electromagnetic calorimeter, and followed by a hadronic calorimeter and a muon identification system. The detector is able to distinguish interactions of all three neutrino flavours, which allows probing the physics of heavy flavour production at the LHC in the very forward region. This region is of particular interest for future circular colliders and for very high energy astrophysical neutrino experiments. The detector is also able to search for the scattering of Feebly Interacting Particles. In its first phase, the detector is ready to operate throughout LHC Run 3 and collect a total of 250 fb-1.

19 July 2023 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
RARaffaele Albanese
Raffaele Albanese
AAAndrey Alexandrov
Andrey Alexandrov
FAF. Alicante
F. Alicante
AAAnna Anokhina
Anna Anokhina
TAT. Asada
T. Asada
SCSnd@Lhc Collaboration
Snd@Lhc Collaboration
We report the direct observation of muon neutrino interactions with the SND@LHC detector at the Large Hadron Collider. A dataset of proton-proton collisions at s=13.6  TeV collected by SND@LHC in 2022 is used, corresponding to an integrated luminosity of 36.8  fb−1. The search is based on information from the active electronic components of the SND@LHC detector, which covers the pseudorapidity region of 7.2<η<8.4, inaccessible to the other experiments at the collider. Muon neutrino candidates are identified through their charged-current interaction topology, with a track propagating through the entire length of the muon detector. After selection cuts, 8 νμ interaction candidate events remain with an estimated background of 0.086 events, yielding a significance of about 7 standard deviations for the observed νμ signal.

25 July 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
BPBeomjun Park
Beomjun Park
JKJuyoung Ko
Juyoung Ko
JBJangwon Byun
Jangwon Byun
SPSandeep Pandey
Sandeep Pandey
BPByungdo Park
Byungdo Park
MLMan-Jong Lee
Man-Jong Lee
Perovskite single crystals are actively studied as X-ray detection materials with enhanced sensitivity. Moreover, the feasibility of using perovskites for self-powered devices such as photodetectors, UV detectors, and X-ray detectors can significantly expand their application range. In this work, the charge carrier transport and photocurrent properties of MAPbBr3 single crystals (MSCs) are improved by the mechanochemical surface treatment using glycerin combined with an additional electrode design that forms an ohmic contact. The sensitivity of MSC-based detectors and pulse shape generated by X-rays are enhanced at various bias voltages. The synthesized MSC detectors generate direction-dependent photocurrents, which indicate the presence of a polarization-induced internal electric field. In addition, photocurrent signals are produced by X-rays with energies greater than 1 MeV under a zero-bias voltage. This work demonstrates a high application potential of perovskites as self-powered detectors for X-rays with energies exceeding 1 MeV.

13 June 2025 in Physical Review Letters
Verified
Journal Article
Open access
DAD. Abbaneo
D. Abbaneo
SAS. Ahmad
S. Ahmad
RARaffaele Albanese
Raffaele Albanese
AAAndrey Alexandrov
Andrey Alexandrov
FAF. Alicante
F. Alicante
SCSnd@Lhc Collaboration
Snd@Lhc Collaboration
We report the observation of neutrino interactions without final state muons at the LHC, with a significance of 6.4 σ . A dataset of proton-proton collisions at s = 13.6 TeV collected by SND@LHC in 2022 and 2023 is used, corresponding to an integrated luminosity of 68.6 fb − 1 . Neutrino interactions without a reconstructed muon are selected, resulting in an event sample consisting mainly of neutral-current and electron neutrino charged-current interactions in the detector. After selection cuts, 9 neutrino interaction candidate events are observed with an estimated background of 0.32 events.

31 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
JKJeongho Kim
Jeongho Kim
JPJeehoon Park
Jeehoon Park
BPByungdo Park
Byungdo Park
YKYonghoon Kim
Yonghoon Kim
BPBeomjun Park
Beomjun Park
SPSo Hyun Park
So Hyun Park
Existing dosimeters for radiation therapy are typically large, and their performance in in vivo system applications has not been assessed. This study develops a compact real-time dosimeter using silicon photomultipliers, plastic scintillators, and optical fibers and evaluates its in vivo applicability for radiation therapy. Dose calibration, dose-rate dependency and linearity, and short-term repeatability tests were conducted using solid water phantoms and bolus materials, and in vivo dosimetry was performed using an in-house phantom. The characterization evaluation results showed high linearity, with a coefficient of determination of 0.9995 for dose rates of 100–600 monitoring units (MU)/min, confirming an error rate within 2% when converted to dosage. In the short-term repeatability tests, the dosimeter exhibited good characteristics, with relative standard deviation (RSD) values lower than 2% for each beam delivery and an RSD value of 0.03% over ten beam deliveries. Dose measurements using the phantom indicated an average error rate of 3.83% compared to the values calculated using the treatment planning system. These results demonstrate a performance comparable to that of commercial metal-oxide-semiconductor field-effect transistors and plastic scintillator-based dosimeters. Based on these findings, the developed dosimeter has significant potential for in vivo radiation therapy applications.

25 June 2024 in Journal of High Energy Physics
Verified
Journal Article
Open access
PDF file
KCKi-Young Choi
Ki-Young Choi
SKSung Hyun Kim
Sung Hyun Kim
YKYeong Gyun Kim
Yeong Gyun Kim
KLKang Young Lee
Kang Young Lee
KLKyong Sei Lee
Kyong Sei Lee
CYChun Sil Yoon
Chun Sil Yoon
We study the expected sensitivity to the mixing between sterile and tau neutrinos directly from the tau neutrino disappearance in the high-energy fixed target experiment. Here, the beam energy is large enough to produce tau neutrinos at the target with large luminosity. During their propagation to the detector, tau neutrinos may oscillate into sterile neutrinos. By examining the energy spectrum of the observed tau neutrino events, we can probe the mixing between sterile and tau neutrinos directly. In this paper, we consider Scattering and Neutrino Detector (SND) at SHiP experiment as a showcase, which uses 400 GeV protons from SPS at CERN, and expect to observe 7,300 tau and anti-tau neutrinos from the 2 × 1020 POT for 5 years operation. Assuming the uncertainty of 10%, we find the sensitivity |U τ4|2 ∼ 0.08 (90% CL) for $$ \Delta {m}_{41}^2 $$ ∆ m 41 2 ∼ 500 eV2 with 10% background to the signal. We also consider a far SND at the end of the SHiP Hidden Sector Decay Spectrometer (HSDS), in which case the sensitivity would be enhanced to |U τ4|2 ∼ 0.02. Away from this mass, the sensitivity becomes lower than |U τ4|2 ∼ 0.15 for $$ \Delta {m}_{41}^2 $$ ∆ m 41 2 ≲ 100 eV2 or $$ \Delta {m}_{41}^2 $$ ∆ m 41 2 ≳ 104eV2.