Perovskite single crystals are actively studied as X-ray detection materials with enhanced sensitivity. Moreover, the feasibility of using perovskites for self-powered devices such as photodetectors, UV detectors, and X-ray detectors can significantly expand their application range. In this work, the charge carrier transport and photocurrent properties of MAPbBr3 single crystals (MSCs) are improved by the mechanochemical surface treatment using glycerin combined with an additional electrode design that forms an ohmic contact. The sensitivity of MSC-based detectors and pulse shape generated by X-rays are enhanced at various bias voltages. The synthesized MSC detectors generate direction-dependent photocurrents, which indicate the presence of a polarization-induced internal electric field. In addition, photocurrent signals are produced by X-rays with energies greater than 1 MeV under a zero-bias voltage. This work demonstrates a high application potential of perovskites as self-powered detectors for X-rays with energies exceeding 1 MeV.
Existing dosimeters for radiation therapy are typically large, and their performance in in vivo system applications has not been assessed. This study develops a compact real-time dosimeter using silicon photomultipliers, plastic scintillators, and optical fibers and evaluates its in vivo applicability for radiation therapy. Dose calibration, dose-rate dependency and linearity, and short-term repeatability tests were conducted using solid water phantoms and bolus materials, and in vivo dosimetry was performed using an in-house phantom. The characterization evaluation results showed high linearity, with a coefficient of determination of 0.9995 for dose rates of 100–600 monitoring units (MU)/min, confirming an error rate within 2% when converted to dosage. In the short-term repeatability tests, the dosimeter exhibited good characteristics, with relative standard deviation (RSD) values lower than 2% for each beam delivery and an RSD value of 0.03% over ten beam deliveries. Dose measurements using the phantom indicated an average error rate of 3.83% compared to the values calculated using the treatment planning system. These results demonstrate a performance comparable to that of commercial metal-oxide-semiconductor field-effect transistors and plastic scintillator-based dosimeters. Based on these findings, the developed dosimeter has significant potential for in vivo radiation therapy applications.
Jiwon Sung, Hyeongmin Jin, Jeongho Kim, Jong Min Park, Jung-in Kim, Chang Heon Choi, Minsoo Chun. Progress in Medical Physics 2020;31:163-71. https://doi.org/10.14316/pmp.2020.31.4.163