7 June 2016 in Magnetic Resonance in Medicine
25 April 2017 in Magnetic Resonance in Medicine
Purpose: Design, implement, integrate, and characterize a customized coil system that allows for generating spatial encoding magnetic fields (SEMs) in a highly‐flexible fashion.Methods: A gradient coil with a high number of individual elements was designed. Dimensions of the coil were chosen to mimic a whole‐body gradient system, scaled down to a head insert. Mechanical shape and wire layout of each element were optimized to increase the local gradient strength while minimizing eddy current effects and simultaneously considering manufacturing constraints.Results: Resulting wire layout and mechanical design is presented. A prototype matrix gradient coil with 12 × 7 = 84 elements consisting of two element types was realized and characterized. Measured eddy currents are <1% of the original field. The coil is shown to be capable of creating nonlinear, and linear SEMs. In a DSV of 0.22 m gradient strengths between 24 mT∕m and 78 mT∕m could be realized locally with maximum currents of 150 A. Initial proof‐of‐concept imaging experiments using linear and nonlinear encoding fields are demonstrated.Conclusion: A shielded matrix gradient coil setup capable of generating encoding fields in a highly‐flexible manner was designed and implemented. The presented setup is expected to serve as a basis for validating novel imaging techniques that rely on nonlinear spatial encoding fields. Magn Reson Med 79:1181–1191, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
5 October 2012 in Magnetic Resonance in Medicine
1 August 2017 in Journal of Magnetic Resonance
29 April 2013 in IEEE Transactions on Medical Imaging
Estimation of multiple T 2 components within single imaging voxels typically proceeds in one of two ways; a nonparametric grid approximation to a continuous distribution is made and a regularized nonnegative least squares algorithm is employed to perform the parameter estimation, or a parametric multicomponent model is assumed with a maximum likelihood estimator for the component estimation. In this work, we present a Bayesian algorithm based on the principle of progressive correction for the latter choice of a discrete multicomponent model. We demonstrate in application to simulated data and two experimental datasets that our Bayesian approach provides robust and accurate estimates of both the T 2 model parameters and nonideal flip angles. The second contribution of the paper is to present a Cramér-Rao analysis of T 2 component width estimators. To this end, we introduce a parsimonious parametric and continuous model based on a mixture of inverse-gamma distributions. This analysis supports the notion that T 2 spread is difficult, if not infeasible, to estimate from relaxometry data acquired with a typical clinical paradigm. These results justify the use of the discrete distribution model.
31 March 2014 in Magnetic Resonance in Medicine
Purpose PatLoc (Parallel Imaging Technique using Localized Gradients) accelerates imaging and introduces a resolution variation across the field-of-view. Higher-dimensional encoding employs more spatial encoding magnetic fields (SEMs) than the corresponding image dimensionality requires, e.g. by applying two quadratic and two linear spatial encoding magnetic fields to reconstruct a 2D image. Images acquired with higher-dimensional single-shot trajectories can exhibit strong artifacts and geometric distortions. In this work, the source of these artifacts is analyzed and a reliable correction strategy is derived. Methods A dynamic field camera was built for encoding field calibration. Concomitant fields of linear and nonlinear spatial encoding magnetic fields were analyzed. A combined basis consisting of spherical harmonics and concomitant terms was proposed and used for encoding field calibration and image reconstruction. Results A good agreement between the analytical solution for the concomitant fields and the magnetic field simulations of the custom-built PatLoc SEM coil was observed. Substantial image quality improvements were obtained using a dynamic field camera for encoding field calibration combined with the proposed combined basis. Conclusion The importance of trajectory calibration for single-shot higher-dimensional encoding is demonstrated using the combined basis including spherical harmonics and concomitant terms, which treats the concomitant fields as an integral part of the encoding. Magn Reson Med 73:1340–1357, 2015.