30 April 2024 in ACM Transactions on Cyber-Physical Systems
Deep reinforcement learning (DRL) has shown good performance in tackling Markov decision process (MDP) problems. As DRL optimizes a long-term reward, it is a promising approach to improving the energy efficiency of data-center cooling. However, enforcement of thermal safety constraints during DRL’s state exploration is a main challenge. The widely adopted reward-shaping approach adds negative reward when the exploratory action results in unsafety. Thus, it needs to experience sufficient unsafe states before it learns how to prevent unsafety. In this article, we propose a safety-aware DRL framework for data-center cooling control. It applies offline imitation learning and online post-hoc rectification to holistically prevent thermal unsafety during online DRL. In particular, the post-hoc rectification searches for the minimum modification to the DRL-recommended action such that the rectified action will not result in unsafety. The rectification is designed based on a thermal state transition model that is fitted using historical safe operation traces and able to extrapolate the transitions to unsafe states explored by DRL. Extensive evaluation for chilled water and direct expansion-cooled data centers in two climate conditions show that our approach saves 18% to 26.6% of total data-center power compared with conventional control and reduces safety violations by 94.5% to 99% compared with reward shaping. We also extend the proposed framework to address data centers with non-uniform temperature distributions for detailed safety considerations. The evaluation shows that our approach saves 14% power usage compared with the PID control while addressing safety compliance during the training.
26 October 2023 in ACM Transactions on Modeling and Computer Simulation
Computational fluid dynamics (CFD) models have been widely used for prototyping data centers. Evolving them into high-fidelity and real-time digital twins is desirable for the online operations of data centers. However, CFD models often have unsatisfactory accuracy and high computation overhead. Manually calibrating the CFD model parameters is tedious and labor-intensive. Existing automatic calibration approaches apply heuristics to search the model configurations. However, each search step requires a long-lasting process of repeatedly solving the CFD model, rendering them impractical, especially for complex CFD models. This article presents Kalibre , a knowledge-based neural surrogate approach that calibrates a CFD model by iterating four steps of (i) training a neural surrogate model, (ii) finding the optimal parameters through neural surrogate retraining, (iii) configuring the found parameters back to the CFD model, and (iv) validating the CFD model using sensor-measured data. Thus, the parameter search is offloaded to the lightweight neural surrogate. To speed up Kalibre’s convergence, we incorporate prior knowledge in training data initialization and surrogate architecture design. With about ten hours of computation on a 64-core processor, Kalibre achieves mean absolute errors (MAEs) of 0.57°C and 0.88°C in calibrating the CFD models of two production data halls hosting thousands of servers. To accelerate CFD-based simulation, we further propose Kalibreduce that incorporates the energy balance principle to reduce the order of the calibrated CFD model. Evaluation shows the model reduction only introduces 0.1°C to 0.27°C extra errors while accelerating the CFD-based simulations by thousand times.
28 January 2026 in IEEE Energy Sustainability Magazine
The revolution in artificial intelligence (AI) has brought sustainable challenges in data center (DC) management due to the high carbon emissions and short cooling response time associated with high-power density racks. While machine learning (ML) offers promise for intelligent management, its adoption is hindered by safety and reliability concerns. To address this, we propose a multiphysics-informed ML (MPIML) framework that integrates physical priors into data-driven models for enhanced accuracy and safety. We introduce an integrated system architecture comprising three core engines: DCLib for versatile facility modeling, DCTwin for high-fidelity multiphysics simulation, and DCBrain for decision-making optimization. This system enables critical predictive and prescriptive applications, such as carbon-aware information technology (IT) capacity provisioning, safety-aware intelligent cooling control, and battery health forecasting. An illustrative example on an industry-grade DC cooling control demonstrates that our MPIML approach reduces annual carbon emissions up to 200 kilotons compared with conventional methods while ensuring operational constraints are met. We conclude by outlining key challenges and future directions for developing autonomous and sustainable DCs.