17 March 2021 in IEEE Transactions on Instrumentation and Measurement
Phase-shifting profilometry (PSP) is a method used to establish the pixel correspondence between a projector and a camera using phase-shifting fringe patterns. Due to the nonlinear intensity response of the captured images, nonlinear errors will be induced into the calculated phase and thus decrease the accuracy of 3-D measurement. In this article, we propose a fast self-correction algorithm to reduce the nonlinear phase error without the need for additional projections or precalibration. In this study, we derived an average intensity expression of the captured fringe images that contain the nonlinear response parameters. We can establish a set of equations with the known projection fringe information and unknown nonlinear parameters based on the captured fringe images at different frequencies used in the multifrequency heterodyne algorithm. Based on the equation set, the nonlinear response parameters can be solved for each pixel in the captured images, and the inverse function of the system response can thus be obtained and used to correct the actual nonlinear gray value. This pointwise correction algorithm can reduce the nonlinear phase error corresponding to different frequency fringe images without increasing the number of projections and with no excessive calculation time. Furthermore, this method can use small-pitch fringe patterns to improve the measurement accuracy while maintaining the reliability of the phase unwrapping. Experimental results show that the proposed method can eliminate the nonlinear phase error, improve phase unwrapping robustness, and achieve a high measurement quality for fast 3-D measurement through PSP.
29 July 2021 in Optics Letters
The measurement accuracy of high-speed binary defocusing fringe projection profilometry depends on the fringe pitch and defocus degree. During the measurement process, the degree of defocus changes with the measurement depth of the scenes. This makes it difficult to obtain a suitable defocus degree and achieve high-precision measurement owing to dynamic changes in the measurement object or environment. To address this problem, we propose a highly dynamic defocus response method to adaptively adjust fringe pitches for binary defocusing fringe projection profilometry. As the defocus degree changes significantly, the proposed method can respond quickly and adjust the fringe pitches adaptively to the scenes. Therefore, a high-precision dynamic measurement can be achieved for the current measuring scene. In this study, considering the effect of random error and nonlinear error, we established a complete phase-error model and used it as an optimization function. Based on this function, we obtained the optimal fringe pitch expression with the defocus degree and harmonic response parameters as variables. With the proposed method, we can obtain the defocus degree and harmonic response parameters during the measurement process and calculate the optimal fringe pitches for the current scenes. Thus, the proposed method can dynamically adapt to the measuring depth change and achieve an accurate measurement without modifying any hardware parameters.
8 July 2022 in Optics Letters
Current binary defocus technology mainly focuses on fringe generation suitable for specific frequencies without considering fringe adaptability for defocus-degree variation, which decreases the measuring accuracy for this scenario. To achieve a high-quality measurement, we propose a robust binary fringe generation method to minimize the phase error caused by changes in defocus and the random error in measurement. In the method, we establish a complete phase error model and construct a novel objective function, to the best of our knowledge, to optimize the binarization threshold of each pixel. Through derivation of the threshold gradient calculation formula, we quickly obtain optimal binary fringes that can adapt to different fringe pitches and various degrees of defocus. The experimental results verify that the proposed method can generate robust binary fringes adaptive to different fringe pitches and defocus degree variation, and thus achieve high-quality 3D measurements.
25 May 2022 in IEEE Transactions on Industrial Electronics
Binary defocusing technique is typically used in high-speed 3-D measurement. As the defocus degree varies with the measuring depth range, current defocusing technique has limitations while measuring large-depth-range (LDR) scene. Addressing this difficulty, this article proposes a novel defocus-degree-based phase unwrapping and phase fusion algorithm for LDR 3-D measurement. Firstly, we establish a mathematical model to present the relationship between defocus degree and phase, and present the defocus-degree-based phase unwrapping algorithm to directly obtain its accurate fringe order. Then, we derive a phase error model to estimate its phase error, and develop a phase fusion algorithm to obtain the lowest phase error by fusing two frequency phases based on the estimated error. With implementation of the proposed phase unwrapping and fusion algorithm, experiments are performed and the results demonstrate that our method can achieve a high-speed, high-precision and low-outlier 3-D measurement for LDR scene.
17 March 2025 in IEEE Transactions on Instrumentation and Measurement
White light interferometry is commonly illuminated using stable and long-lasting white LEDs. However, the measurement process is susceptible to the spectral effects of LEDs and environmental vibrations, which will reduce its reconstruction accuracy. This paper proposes a composite phase-shifting and height fusion algorithm to rectify the spectral distortions caused by LED light sources and minimize vibration impact by correcting errors arising from the special spectral effects in phase-shifting interferometry. Through the composite phase-shifting algorithm, this paper constructs a composite Gaussian phase shift model based on the dual-peak spectral characteristics of LED light sources to extract phase information. Then, a height fusion algorithm is presented to suppress the impact of vibration in the measuring process. This algorithm proves that the height error of the phase-shifting method has the characteristic of normal distribution, and thus lays a theoretical basis for its average calculation of random error suppression. Through plane measurement simulations and standard step height measurement experiments, the proposed method was validated consistently with high measurement accuracy and stability under various degrees of vibration interference. Compared with other methods, the proposed method can reduce the impact of LED dual-peak spectral and dynamic vibration interference on the measurements, and thus significantly enhance 3D reconstruction accuracy for white light interferometric measurement.
1 January 2026 in IEEE Transactions on Instrumentation and Measurement