1 July 2016 in Reports of Practical Oncology and Radiotherapy
An extremely large variety of benign and malignant tumours occur at skull base; these tumour lesions are in the proximity to structures deputed to relevant physiologic functions, limiting extensive surgical approaches to this body district. Most recent progresses of surgery and radiotherapy have allowed to improve local control with acceptable rates of side effects. Various photon radiotherapy techniques are employed, including 3-dimensional conformal radiotherapy, intensity modulated radiotherapy (IMRT), stereotactic radiotherapy (SRT) and brachytherapy that is manly limited to the treatment of primary or recurrent nasopharyngeal carcinoma. Proton beam radiotherapy is also extensively used thanks to its physical characteristics. Our review, focusing in particular on meningioma, chordoma, and chondrosarcoma, suggests that proton therapy plays a major role in the treatment of malignant tumours whereas photon therapy still plays a relevant role in the treatment of benign tumour lesions.
23 February 2020 in Acta Oncologica
Objective: To compare radiation-induced toxicity and dosimetry parameters in patients with locally advanced nasopharyngeal cancer (LANPC) treated with a mixed-beam (MB) approach (IMRT followed by proton therapy boost) with an historic cohort of patients treated with a full course of IMRT-only. Material and methods: Twenty-seven patients with LANPC treated with the MB approach were compared to a similar cohort of 17 patients treated with IMRT-only. The MB approach consisted in a first phase of IMRT up to 54–60 Gy followed by a second phase delivered with a proton therapy boost up to 70–74 Gy (RBE). The total dose for patients treated with IMRT-only was 69.96 Gy. Induction chemotherapy was administrated to 59 and 88% and concurrent chemoradiotherapy to 88 and 100% of the MB and IMRT-only patients, respectively. The worst toxicity occurring during the entire course of treatment (acute toxicity) and early-late toxicity were registered according to the Common Terminology Criteria Adverse Events V4.03. Results: The two cohorts were comparable. Patients treated with MB received a significantly higher median total dose to target volumes (p = .02). Acute grade 3 mucositis was found in 11 and 76% (p = .0002) of patients treated with MB and IMRT-only approach, respectively, while grade 2 xerostomia was found in 7 and 35% (p = .02) of patients treated with MB and IMRT-only, respectively. There was no statistical difference in late toxicity. Local progression-free survival (PFS) and progression-free survival curves were similar between the two cohorts of patients (p = .17 and p = .40, respectively). Local control rate was 96% and 81% for patients treated with MB approach and IMRT-only, respectively. Conclusions: Sequential MB approach for LANPC patients provides a significantly lower acute toxicity profile compared to full course of IMRT. There were no differences in early-late morbidities and disease-related outcomes (censored at two-years) but a longer follow-up is required to achieve conclusive results.
8 September 2016 in Journal of Applied Clinical Medical Physics
Particle therapy (PT) has shown positive therapeutic results in local control of locally advanced pancreatic lesions. PT effectiveness is highly influenced by target localization accuracy both in space, since the pancreas is located in proximity to radiosensitive vital organs, and in time as it is subject to substantial breathing-related motion. The purpose of this preliminary study was to quantify pancreas range of motion under typical PT treatment conditions. Three common immobilization devices (vacuum cushion, thermoplastic mask, and compressor belt) were evaluated on five male patients in prone and supine positions. Retrospective four-dimensional magnetic resonance imaging data were reconstructed for each condition and the pancreas was manually segmented on each of six breathing phases. A k-means algorithm was then applied on the manually segmented map in order to obtain clusters representative of the three pancreas segments: head, body, and tail. Centers of mass (COM) for the pancreas and its segments were computed, as well as their displacements with respect to a reference breathing phase (beginning exhalation). The median three-dimensional COM displacements were in the range of 3 mm. Latero–lateral and superior–inferior directions had a higher range of motion than the anterior–posterior direction. Motion analysis of the pancreas segments showed slightly lower COM displacements for the head cluster compared to the tail cluster, especially in prone position. Statistically significant differences were found within patients among the investigated setups. Hence a patient-specific approach, rather than a general strategy, is suggested to define the optimal treatment setup in the frame of a millimeter positioning accuracy. PACS number(s): 87.55.-x, 87.57.nm, 87.61