Tess E. Wallace

Tess E. Wallace

Auto-generated profile, based on publicly available information

Tess E. Wallace

Computational Radiology Laboratory, Department of Radiology Boston Children's Hospital Boston Massachusetts USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
TWTess E. Wallace
Tess E. Wallace
OAOnur Afacan
Onur Afacan
MWMaryna Waszak
Maryna Waszak
TKTobias Kober
Tobias Kober
SWSimon K. Warfield
Simon K. Warfield

29 August 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
TWTess E. Wallace
Tess E. Wallace
OAOnur Afacan
Onur Afacan
TKTobias Kober
Tobias Kober
SWSimon K. Warfield
Simon K. Warfield
Purpose: To measure spatiotemporal B0 field changes in real time using FID navigators (FIDnavs) and to demonstrate the efficacy of retrospectively correcting high‐resolution ‐weighted images using a novel FIDnav framework.Methods: A forward model of the complex FIDnav signals was generated by simulating the effect of changes in the underlying B0 inhomogeneity coefficients, with spatial encoding provided by a multi‐channel reference image. Experiments were performed at 3T to assess the accuracy of B0 field estimates from FIDnavs acquired from a 64‐channel head coil under different shim settings and in 5 volunteers performing deep‐breathing and nose‐touching tasks designed to modulate the B0 field. Second‐order, in‐plane spherical harmonic (SH) inhomogeneity coefficients estimated from FIDnavs were incorporated into an iterative reconstruction to retrospectively correct 2D gradient‐echo images acquired in both axial and sagittal planes.Results: Spatiotemporal B0 field changes measured from rapidly acquired FIDnavs were in good agreement with the results of second‐order SH fitting to the measured field maps. FIDnav field estimates accounted for a significant proportion of the ΔB0 variance induced by deep breathing (64 ± 21%) and nose touching (67 ± 34%) across all volunteers. Ghosting, blurring, and intensity modulation artifacts in ‐weighted images, induced by spatiotemporal field changes, were visibly reduced following retrospective correction with FIDnav inhomogeneity coefficients.Conclusions: Spatially resolved B0 inhomogeneity changes up to second order can be characterized in real time using the proposed approach. Retrospective FIDnav correction substantially improves ‐weighted image quality in the presence of strong B0 field modulations, with potential for real‐time shimming.

10 August 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
OAOnur Afacan
Onur Afacan
TWTess E. Wallace
Tess E. Wallace
SWSimon K. Warfield
Simon K. Warfield

24 September 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
TWTess E. Wallace
Tess E. Wallace
JPJonathan R. Polimeni
Jonathan R. Polimeni
JSJason P. Stockmann
Jason P. Stockmann
WHW. Scott Hoge
W. Scott Hoge
TKTobias Kober
Tobias Kober
OAOnur Afacan
Onur Afacan

12 September 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
TWTess E. Wallace
Tess E. Wallace
TKTobias Kober
Tobias Kober
JSJason P. Stockmann
Jason P. Stockmann
JPJonathan R. Polimeni
Jonathan R. Polimeni
SWSimon K. Warfield
Simon K. Warfield
OAOnur Afacan
Onur Afacan

5 September 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
CACemre Ariyurek
Cemre Ariyurek
TWTess E. Wallace
Tess E. Wallace
TKTobias Kober
Tobias Kober
SKSila Kurugol
Sila Kurugol
OAOnur Afacan
Onur Afacan