6 January 2024 in Journal of Biomedical Informatics
9 March 2020 in IEEE Transactions on Biomedical Circuits and Systems
This paper considers implementation of artificial neural networks (ANNs) using molecular computing and DNA based on fractional coding. Prior work had addressed molecular two-layer ANNs with binary inputs and arbitrary weights. In prior work using fractional coding, a simple molecular perceptron that computes sigmoid of scaled weighted sum of the inputs was presented where the inputs and the weights lie between [-1,1]. Even for computing the perceptron, the prior approach suffers from two major limitations. First, it cannot compute the sigmoid of the weighted sum, but only the sigmoid of the scaled weighted sum. Second, many machine learning applications require the coefficients to be arbitrarily positive and negative numbers that are not bounded between [-1,1]; such numbers cannot be handled by the prior perceptron using fractional coding. This paper makes four contributions. First molecular perceptrons that can handle arbitrary weights and can compute sigmoid of the weighted sums are presented. Thus, these molecular perceptrons are ideal for regression applications and multi-layer ANNs. A new molecular divider is introduced and is used to compute sigmoid(ax) where a>1. Second, based on fractional coding, a molecular artificial neural network (ANN) with one hidden layer is presented. Third, a trained ANN classifier with one hidden layer from seizure prediction application from electroencephalogram is mapped to molecular reactions and DNA and their performances are presented. Fourth, molecular activation functions for rectified linear unit (ReLU) and softmax are also presented.
13 May 2022 in ACS Synthetic Biology
5 September 2023 in IEEE Transactions on Biomedical Circuits and Systems
This paper proposes molecular and DNA memristors where the state is defined by a single output variable. In past molecular and DNA memristors, the state of the memristor was defined based on two output variables. These memristors cannot be cascaded because their input and output sizes are different. We introduce a different definition of state for the molecular and DNA memristors. This change allows cascading of memristors. The proposed memristors are used to build reservoir computing (RC) models that can process temporal inputs. An RC system consists of two parts: reservoir and readout layer . The first part projects the information from the input space into a high-dimensional feature space. We also study the input-state characteristics of the cascaded memristors and show that the cascaded memristors retain the memristive behavior. The cascade connections in a reservoir can change dynamically ; this allows the synthesis of a dynamic reservoir as opposed to a static one in the prior work. This reduces the number of memristors significantly compared to a static reservoir. The inputs to the readout layer correspond to one molecule per state instead of two; this significantly reduces the number of molecular and DSD reactions for the readout layer. A DNA RC system consisting of DNA memristors and a DNA readout layer is used to detect seizures from intra-cranial electroencephalogram (iEEG). We also demonstrate that a DNA RC system consisting of three cascaded DNA memristors and a DNA readout layer can be used to solve the time-series prediction task. The proposed approach can reduce the number of DNA strand displacement (DSD) reactions by three to five times compared to prior approaches.
23 January 2026 in Scientific Reports
With global aging, assessing functional status is vital for precision medicine. Electronic Health Records (EHRs), particularly unstructured data, hold abundant information on patient mobility. This study explores using Large Language Models (LLMs) to extract and standardize mobility status from unstructured EHR data (i.e., clinical notes). We annotated 600 clinical notes from three healthcare institutions located in southeastern Minnesota and west-central Wisconsin, focusing on expressions of mobility and associated impairment. Leveraging the open-source Llama 3 model, we tested various prompting strategies, including zero-shot, few-shot, and task decomposition, and evaluated their performance. Error analysis showed that while the model sometimes inferred impairments without explicit evidence, most errors were clinically reasonable, often reflecting borderline or ambiguous cases. Our final model achieved a patient-level micro-average F1-score of 0.876 [95% CI 0.858–0.894] for Mobility Extraction and 0.897 [95% CI 0.878–0.917] for Impairment Classification. A secondary analysis counting “clinically reasonable inferences” as correct, performed to assess clinical plausibility, yielded F1-scores of 0.962 [95% CI 0.952–0.971] and 0.948 [95% CI 0.936–0.960], respectively. A local, deterministic setup improved trustworthiness by ensuring consistent outputs, safeguarding privacy, and demonstrating cross-institution generalizability. These findings highlight the feasibility of LLM-based solutions for extracting mobility functional status from unstructured EHR data, supporting both clinical applications and research.