14 April 2021 in Acta Neurochirurgica
Background: Cerebrospinal compliance describes the ability of the cerebrospinal space to buffer changes in volume. Diminished compliance is associated with increased risk of potentially threatening increases in intracranial pressure (ICP) when changes in cerebrospinal volume occur. However, despite various methods of estimation proposed so far, compliance is seldom used in clinical practice. This study aimed to compare three measures of cerebrospinal compliance. Methods: ICP recordings from 36 normal-pressure hydrocephalus patients who underwent infusion tests with parallel recording of transcranial Doppler blood flow velocity were retrospectively analysed. Three methods were used to calculate compliance estimates during changes in the mean ICP induced by infusion of fluid into the cerebrospinal fluid space: (a) based on Marmarou’s model of cerebrospinal fluid dynamics (CCSF), (b) based on the evaluation of changes in cerebral arterial blood volume (CCaBV), and (c) based on the amplitudes of peaks P1 and P2 of ICP pulse waveform (CP1/P2). Results: Increase in ICP caused a significant decrease in all compliance estimates (p < 0.0001). Time courses of compliance estimators were strongly positively correlated with each other (group-averaged Spearman correlation coefficients: 0.94 [0.88–0.97] for CCSF vs. CCaBV, 0.77 [0.63–0.91] for CCSF vs. CP1/P2, and 0.68 [0.48–0.91] for CCaBV vs. CP1/P2). Conclusions: Indirect methods, CCaBV and CP1/P2, allow for the assessment of relative changes in cerebrospinal compliance and produce results exhibiting good correlation with the direct method of volumetric manipulation. This opens the possibility of monitoring relative changes in compliance continuously.
1 October 2023 in Physiological Measurement
Continuous monitoring of mean intracranial pressure (ICP) has been an essential part of neurocritical care for more than half a century. Cerebrospinal pressure–volume compensation, i.e. the ability of the cerebrospinal system to buffer changes in volume without substantial increases in ICP, is considered an important factor in preventing adverse effects on the patient’s condition that are associated with ICP elevation. However, existing assessment methods are poorly suited to the management of brain injured patients as they require external manipulation of intracranial volume. In the 1980s, studies suggested that spontaneous short-term variations in the ICP signal over a single cardiac cycle, called the ICP pulse waveform, may provide information on cerebrospinal compensatory reserve. In this review we discuss the approaches that have been proposed so far to derive this information, from pulse amplitude estimation and spectral techniques to most recent advances in morphological analysis based on artificial intelligence solutions. Each method is presented with focus on its clinical significance and the potential for application in standard clinical practice. Finally, we highlight the missing links that need to be addressed in future studies in order for ICP pulse waveform analysis to achieve widespread use in the neurocritical care setting.
11 June 2021 in IEEE Journal of Biomedical and Health Informatics
Objective. Mean intracranial pressure (ICP) is commonly used in the management of patients with intracranial pathologies. However, the shape of the ICP signal over a single cardiac cycle, called ICP pulse waveform, also contains information on the state of the craniospinal space. In this study we aimed to propose an end-to-end approach to classification of ICP waveforms and assess its potential clinical applicability. Methods. ICP pulse waveforms obtained from long-term ICP recordings of 50 neurointensive care unit (NICU) patients were manually classified into four classes ranging from normal to pathological. An additional class was introduced to simultaneously identify artifacts. Several deep learning models and data representations were evaluated. An independent testing dataset was used to assess the performance of final models. Occurrence of different waveform types was compared with the patients’ clinical outcome. Results. Residual Neural Network using 1-D ICP signal as input was identified as the best performing model with accuracy of 93% in the validation and 82% in the testing dataset. Patients with unfavorable outcome exhibited significantly lower incidence of normal waveforms compared to the favorable outcome group even at ICP levels below 20 mm Hg (median [first-third quartile]: 9 [1–36]% vs. 63 [52–88] %, p = 0.002). Conclusions. Results of this study confirm the possibility of analyzing ICP pulse waveform morphology in long-term recordings of NICU patients. Proposed approach could potentially be used to provide additional information on the state of patients with intracranial pathologies beyond mean ICP.
17 November 2023 in Critical Care
Background: Midline shift and mass lesions may occur with traumatic brain injury (TBI) and are associated with higher mortality and morbidity. The shape of intracranial pressure (ICP) pulse waveform reflects the state of cerebrospinal pressure–volume compensation which may be disturbed by brain injury. We aimed to investigate the link between ICP pulse shape and pathological computed tomography (CT) features. Methods: ICP recordings and CT scans from 130 TBI patients from the CENTER-TBI high-resolution sub-study were analyzed retrospectively. Midline shift, lesion volume, Marshall and Rotterdam scores were assessed in the first CT scan after admission and compared with indices derived from the first 24 h of ICP recording: mean ICP, pulse amplitude of ICP (AmpICP) and pulse shape index (PSI). A neural network model was applied to automatically group ICP pulses into four classes ranging from 1 (normal) to 4 (pathological), with PSI calculated as the weighted sum of class numbers. The relationship between each metric and CT measures was assessed using Mann–Whitney U test (groups with midline shift > 5 mm or lesions > 25 cm3 present/absent) and the Spearman correlation coefficient. Performance of ICP-derived metrics in identifying patients with pathological CT findings was assessed using the area under the receiver operating characteristic curve (AUC). Results: PSI was significantly higher in patients with mass lesions (with lesions: 2.4 [1.9–3.1] vs. 1.8 [1.1–2.3] in those without; p << 0.001) and those with midline shift (2.5 [1.9–3.4] vs. 1.8 [1.2–2.4]; p < 0.001), whereas mean ICP and AmpICP were comparable. PSI was significantly correlated with the extent of midline shift, total lesion volume and the Marshall and Rotterdam scores. PSI showed AUCs > 0.7 in classification of patients as presenting pathological CT features compared to AUCs ≤ 0.6 for mean ICP and AmpICP. Conclusions: ICP pulse shape reflects the reduction in cerebrospinal compensatory reserve related to space-occupying lesions despite comparable mean ICP and AmpICP levels. Future validation of PSI is necessary to explore its association with volume imbalance in the intracranial space and a potential complementary role to the existing monitoring strategies.
1 December 2021 in Physiological Measurement
Objective. Analysis of relative changes in the shapes of pulse waveforms of intracranial pressure (ICP) and transcranial Doppler cerebral blood flow velocity (CBFV) may provide information on intracranial compliance. We tested this hypothesis, introducing an index named the ratio of pulse slopes (RPS) that is based on inclinations of the ascending parts of the ICP and CBFV pulse waveforms. It has hypothetically a simple interpretation: a value of 1 indicates good compliance and a value less than 1, reduced compliance. Here, we investigated the usefulness of RPS for assessment of intracranial compliance. Approach. ICP and CBFV signals recorded simultaneously in 30 normal-pressure hydrocephalus patients during infusion tests were retrospectively analysed. CBFV was measured in the middle cerebral artery. Changes in RPS during the test were compared with changes in the height ratio of the first and second peak of the ICP pulse (P1/P2) and the shape of the ICP pulse was classified from normal (1) to pathological (4). Values are medians (lower, upper quartiles). Main results. There was a significant correlation between baseline RPS and intracranial elasticity ( R = −0.55, p = 0.0018). During the infusion tests, both RPS and P1/P2 decreased with rising ICP [RPS, 0.80 (0.56, 0.92) versus 0.63 (0.44, 0.80), p = 0.00015; P1/P2, 0.58 (0.50, 0.91) versus 0.52 (0.36, 0.71), p = 0.00009] while the ICP pulses became more pathological in shape [class: 3 (2, 3) versus 3 (3, 4), p = 0.04]. The magnitude of the decrease in RPS during infusion was inversely correlated with baseline P1/P2 ( R = −0.40, p < 0.03). Significance. During infusion, the slopes of the ascending parts of ICP and CBFV pulses become increasingly divergent with a shift in opposite directions. RPS seems to be a promising methodological tool for monitoring intracranial compliance with no additional volumetric manipulation required.
3 February 2019 in Computational and Mathematical Methods in Medicine
Baroreflex is a mechanism of short-term neural control responsible for maintaining stable levels of arterial blood pressure (ABP) in an ABP-heart rate negative feedback loop. Its function is assessed by baroreflex sensitivity (BRS)—a parameter which quantifies the relationship between changes in ABP and corresponding changes in heart rate (HR). The effect of postural change as well as the effect of changes in blood O2 and CO2 have been the focus of multiple previous studies on BRS. However, little is known about the influence of the combination of these two factors on dynamic baroreflex response. Furthermore, classical methods used for BRS assessment are based on the assumption of stationarity that may lead to unreliable results in the case of mostly nonstationary cardiovascular signals. Therefore, we aimed to investigate BRS during repeated transitions between squatting and standing in normal end-tidal CO2 (EtCO2) conditions (normocapnia) and conditions of progressively increasing EtCO2 with a decreasing level of O2 (hypercapnia with hypoxia) using joint time and frequency domain (TF) approach to BRS estimation that overcomes the limitation of classical methods. Noninvasive continuous measurements of ABP and EtCO2 were conducted in a group of 40 healthy young volunteers. The time course of BRS was estimated from TF representations of pulse interval variability and systolic pressure variability, their coherence, and phase spectra. The relationship between time-variant BRS and indices of ABP and HR was analyzed during postural change in normocapnia and hypercapnia with hypoxia. In normocapnia, observed trends in all measures were in accordance with previous studies, supporting the validity of presented TF method. Similar but slightly attenuated response to postural change was observed in hypercapnia with hypoxia. Our results show the merits of the nonstationary methods as a tool to study the cardiovascular system during short-term hemodynamic changes.