Background: Recent data have suggested a substantial incidence of atrial arrhythmias (AAs) in cardiac sarcoidosis (CS). Our study aims were to first assess how often AAs are the presenting feature of previously undiagnosed CS. Second, we used prospective follow‐up data from implanted devices to investigate AA incidence, burden, predictors, and response to immunosuppression. Methods and Results: This project is a substudy of the CHASM‐CS (Cardiac Sarcoidosis Multicenter Prospective Cohort Study; NCT01477359). Inclusion criteria were presentation with clinically manifest cardiac sarcoidosis, treatment‐naive status, and implanted with a device that reported accurate AA burden. Data were collected at each device interrogation visit for all patients and all potential episodes of AA were adjudicated. For each intervisit period, the total AA burden was obtained. A total of 33 patients met the inclusion criteria (aged 56.1±7.7 years, 45.5% women). Only 1 patient had important AAs as a part of the initial CS presentation. During a median follow‐up of 49.1 months, 11 of 33 patients (33.3%) had device‐detected AAs, and only 2 (6.1%) had a clinically significant AA burden. Both patients had reduced burden after CS was successfully treated and there was no residual fluorodeoxyglucose uptake on positron emission tomography scan. Conclusions: First, we found that AAs are a rare presenting feature of clinically manifest cardiac sarcoidosis. Second, AAs occurred in a minority of patients at follow‐up; the burden was very low in most patients. Only 2 patients had clinically significant AA burden, and both had a reduction after CS was treated. Registration: URL: https://www.clinicaltrials.gov ; unique identifier NCT01477359.
28 November 2020 in Cardiovascular Digital Health Journal
There are little data on the use of virtual care for patients with arrhythmia. We evaluated a virtual clinic platform, in conjunction with specialist care, for patients with symptomatic atrial fibrillation (AF). This was a prospective, observational cohort study evaluating an online educational and treatment platform, with a randomized sub-study examining the use of an ambulatory single-lead electrocardiogram heart monitor (AHM). Follow-up was 6 months. The main outcome was patients’ platform use; success was defined as 90% of patients using the platform at least once, and 75% using it at least twice. The primary outcome in the AHM sub-study was Atrial Fibrillation Symptom Severity (AFSS) score. Other outcomes included patient satisfaction questionnaires, quality of life, emergency department visits, and hospitalizations for AF. We enrolled 94 patients between July 2018 and May 2019; 83% of patients logged in at least once and 54.3% more than once. Patients who were older, were male, or had new-onset AF were more likely to log in to the platform. Satisfaction scores were high; 70%–94% of patients responded favorably. Quality-of-life scores improved at 3 and 6 months. In the AHM sub-study (n = 71), those who received an AHM had lower AFSS scores (least square mean difference -2.52, 95% CI -4.48 to -0.25, P = .03). There was no difference in emergency department visits or hospitalizations. The online platform did not reach our feasibility target but was well received. Allocation of an AHM was associated with improved quality of life. Virtual AF care shows promise and should be evaluated in further research.
Ipsilateral approach in patients requiring cardiac implantable electronic device (CIED) revision or upgrade may not be feasible, primarily due to vascular occlusion. If a new CIED is implanted on the contralateral side, a common practice is to explant the old CIED to avoid device interaction. The purpose of this study was to assess a conservative approach of abandoning the old CIED after implanting a new contralateral device. We used an artificial intelligence algorithm to analyze postimplant chest radiographs to identify those with multiple CIEDs. Outcomes of interest included device interaction, abandoned CIED elective replacement indicator (ERI) behavior, subsequent programming changes, and explant of abandoned CIED. Theoretical risk of infection with removal of abandoned CIED was estimated using a validated scoring system. Among 12,045 patients, we identified 40 patients with multiple CIEDs. Occluded veins were the most common indication for contralateral implantation (n = 27 [67.5%]). Fifteen abandoned CIEDs reached ERI, with 4 reverting to VVI 65. One patient underwent explant due to device interaction, and 2 required device reprogramming. Of 32 patients with an implantable cardioverter-defibrillator, 8 (25%) had treated ventricular arrhythmia. There were no failed or inappropriate therapies due to interaction. Eighteen patients (45%) had hypothetical >1% annual risk of hospitalization for device infection if the abandoned CIED had been explanted. In patients requiring new CIED implant on the contralateral side, abandoning the old device is feasible. This approach may reduce the risk of infection and concerns regarding abandoned leads and magnetic resonance imaging scans. Knowledge of ERI behavior is essential to avoid device interactions.