1 January 2025 in Progress in Biomedical Engineering
With increasing age, motor performance declines. This decline is associated with less favorable health outcomes such as impaired activities of daily living, reduced quality of life, or increased mortality. Through regular assessment of motor performance, changes over time can be monitored, and targeted therapeutic programs and interventions may be informed. This can ensure better individualization of any intervention approach (e.g. by considering the current motor performance status of a person) and thus potentially increase its effectiveness with regard to maintaining current performance status or delaying further decline. However, in older adults, motor performance assessment is time consuming and requires experienced examiners and specific equipment, amongst others. This is particularly not feasible in care facility/nursing home settings. Wearable robotic devices, such as exoskeletons, have the potential of being used to assess motor performance and provide assistance during physical activities and exercise training for older adults or individuals with mobility impairments, thereby potentially enhancing motor performance. In this manuscript, we aim to (1) provide a brief overview of age-related changes of motor performance, (2) summarize established clinical and laboratory test procedures for the assessment of motor performance, (3) discuss the possibilities of translating established test procedures into exoskeleton-based procedures, and (4) highlight the feasibility, technological requirements and prerequisites for the assessment of human motor performance using lower limb exoskeletons.
8 September 2026 in Journal of NeuroEngineering and Rehabilitation
Background: Ankle exoskeletons are widely used to reduce the metabolic cost of walking, yet their effects on walking stability during unperturbed gait remain insufficiently understood. Walking stability can be characterized using complementary measures that capture stride-to-stride variability, global temporal organization, and local dynamic stability. Understanding how walking with an actuated ankle exoskeleton system influences these different aspects of gait stability is essential for the safe design and control of wearable robotic devices. Methods: Eighteen healthy adults walked on a treadmill at a constant speed (1.1 m/s) with and without an actuated bilateral ankle exoskeleton in a randomized crossover design. Spatiotemporal variability was quantified using coefficients of variation (CoV) of stride length, step width, and stance ratio. Global gait stability was assessed using detrended fluctuation analysis of stride time. Local dynamic stability was evaluated using maximum Lyapunov exponent calculated for the trunk, hip, upper leg, lower leg, and foot. Paired-samples two-sided t-tests were used to compare conditions. Results: Walking with the ankle exoskeleton resulted in increased stride-to-stride spatiotemporal variability, reflected by higher CoV values for stride length ( p < 0.001) and stance ratio ( p = 0.005), while mean stride length and step width remained unchanged. Mean stance ratio was reduced in the exoskeleton condition ( p < 0.001). Global gait stability did not differ between conditions, indicating preserved long-range temporal gait organization. Local dynamic stability increased at the lower leg ( p < 0.001) and foot ( p = 0.019) when walking with the exoskeleton. Conclusions: Walking with the actuated ankle exoskeleton alters gait control across multiple levels during steady walking. While stride-to-stride variability in stride length and stance ratio increased, global gait stability remained unchanged. Local dynamic stability was increased at the lower leg and foot, suggesting segment-specific effects of ankle-level assistance close to the assisted joint. However, these findings should be interpreted as the combined effect of wearing the exoskeleton and receiving active assistance, rather than the isolated effect of plantarflexion assistance. These results provide insight for the design and control of ankle exoskeletons with respect to stability-related effects during walking.
22 April 2026 in SSRN Electronic Journal
Background: Ankle exoskeletons alter joint kinematics during walking, yet their effects on the whole-body coordination remain unclear. This study investigated how ankle exoskeleton assistance influences the structure of motor variability and center of mass (COM) movement during steady-state walking.Methods: Twenty healthy adults walked on a treadmill at 1.1 m/s with (Exo) and without (noExo) ankle exoskeleton assistance. Whole-body kinematics were recorded, and variability was analyzed using the Uncontrolled Manifold (UCM) approach. Joint angle variability was decomposed into components that do not affect COM position (UCM||) and components that do (UCM⊥). Their ratio (UCMratio), reflecting the synergy stabilizing the COM, was then calculated. COM position was additionally analyzed separately in three dimensions. Time-continuous differences across the gait cycle were evaluated using statistical parametric mapping.Results: UCM|| and UCMratio showed no significant differences between conditions. In contrast, UCM⊥ was higher with exoskeleton assistance over large portions of the gait cycle (0–80%, p = 0.001; 91–100%, p = 0.022). COM movement in the mediolateral and anteroposterior directions did not differ between conditions, while small differences were observed in the vertical direction (higher in Exo at 23–31% and 75–84%, p = 0.037; lower at 48–54%, p = 0.042).Conclusion: These findings indicate that ankle exoskeleton assistance increases variability affecting COM movement without changing the synergy stabilizing the COM. Task-level motor coordination was preserved, suggesting that control of the COM is maintained despite altered mechanical conditions associated with ankle exoskeleton assistance.
19 June 2026 in Gait & Posture
Ankle exoskeletons alter joint kinematics during walking, yet their effects on whole-body coordination remain unclear. This study investigated how ankle exoskeleton assistance influences the structure of motor variability and center-of-mass movement during steady-state walking. Twenty healthy adults walked on a treadmill at 1.1 m/s without the exoskeleton (noExo) and with active exoskeleton assistance (Exo). Whole-body kinematics were recorded. Variability was analyzed using the Uncontrolled Manifold (UCM) approach. Joint angle variability was decomposed into components that do not affect center-of-mass position (UCM||) and components that do (UCM⊥). Their ratio (UCMratio), reflecting the synergy stabilizing the center-of-mass, was calculated. Center-of-mass position was analyzed separately in three dimensions. Time-continuous differences across the gait cycle were evaluated using statistical parametric mapping. UCM|| and UCMratio showed no significant differences between conditions. UCM⊥ was higher with exoskeleton assistance over large portions of the gait cycle (0-80%, p = 0.001; 91-100%, p = 0.022). Center-of-mass movement in the mediolateral and anteroposterior directions did not differ between conditions, while small differences were observed in the vertical direction (higher in Exo at 23-31% and 75-84%, p = 0.037; lower at 48-54%, p = 0.042). Ankle exoskeleton assistance increased joint-level variability affecting center-of-mass movement, but overall center-of-mass control was preserved, with only small changes in vertical center-of-mass displacement. Healthy adults maintained whole-body coordination despite altered mechanical conditions introduced by the exoskeleton. These findings are relevant for clinical exoskeleton use, where assistive devices should support walking without compromising center-of-mass control and balance.
10 March 2026 in SSRN Electronic Journal
Background: Walking with bilaterally attached loads on the lower limbs is a promising approach to improve gait function, but it alters the mechanics of the lower limbs. Consequently, the central nervous system needs to adapt and presumably form an internal model of the altered condition. However, this motor adaptation and de-adaptation process may jeopardize safe walking. This study aimed to analyze motor adaptation and de-adaptation in response to lower-limb loading.Methods: Sixteen healthy female and male participants walked on a treadmill with and without weight cuffs attached to their thighs and shanks while full-body kinematics were recorded. Motor adaptation and de-adaptation were analyzed using linear and non-linear metrics.Results: Minimum toe clearance was higher at the beginning of the adaptation and de-adaptation phases than during baseline and exponentially returned to baseline over multiple strides. Sagittal knee and ankle range of motion, as well as step width, also reflected motor adaptation, but their values did not fully converge to baseline. Several spatiotemporal parameters were consistently different between loaded and unloaded walking, i.e., showed no motor adaptation. Furthermore, local hip stability was reduced when adapting to lower limb loadingSignificance: The results are compatible with the idea that the central nervous system rapidly selects an established walking pattern that accommodates lower-limb loading while prioritizing safe walking over efficiency.