Since November 2016, the new Regulatory Guideline NP 306.2.208-2016 “Requirements for Seismic Resistance Design and for Evaluation of Seismic Safety of Ukrainian NPPs” [1] has been in force in Ukraine. This Guideline was developed to improve requirements for NPP site seismic hazard assessment, NPP seismic resistance design and assessment/review of Ukrainian NPP seismic safety. Energoatom developed the Organizational and Technical Measures for Implementation of NP 306.2.208-2016 [2] approved by State Nuclear Regulatory Inspectorate of Ukraine to perform NP 306.2.208-2016 [1] requirements. The paper considers the status of Energoatom in implementation of the main organizational and technical measures [2] on increasing seismic resistance of Ukrainian NPP units according to NP 306.2.208-2016 [1]. In particular, these measures are the following: specification of NPP site seismicity considering results of new studies; introduction of changes into classification (seismic categorization) of systems and components; analysis of necessity to consider additional load combinations with seismic loads, specification of assessing seismic resistance of structures, systems and components; seismic probabilistic safety assessment of NPP units.
The paper presents the analysis of experience in using mixed fuel loadings at Ukrainian NPPs (those envisaging simultaneous use of fuel assemblies different in design and/or fuel structure in the core). The stated analysis was performed under implementation of the first stage of research program that envisages in-depth consideration of comprehensive safety analysis of mixed loadings in thermohydraulic, neutronic, mechanical and strength aspects of nuclear fuel operation. The paper formulates the tasks that will ensure reaching of the objective of the stated research program.
New state-of-the-art regulatory document has been developed and implemented in Ukraine to present requirements for seismic hazard assessment of nuclear power plant (NPP) sites and seismic resistance of nuclear power units taking into account lessons learnt from the accident at Fukushima-1 NPP. One of the new important regulatory requirements in this document is the extension of the list of mandatory load combinations, which should be considered in assessing seismic resistance of unit components. Advantages and disadvantages of the algorithm proposed by the operating organization to determine the necessity to consider some load combinations in assessing the seismic resistance of pipelines and thermomechanical equipment based on previously performed seismic strength calculations have been analyzed in the paper. The pipelines as well as the thermomechanical equipment of Zaporizhzhya NPP Unit 3, for which seismic strength evaluation was calculated, have been considered. The results of expert seismic calculations of YP13S02 valve of ZNPP-1 and ZNPP-3 have been provided. The paper presents the comparative analysis of the floor response spectra for the lower, middle and high elevations of ZNPP-3 containment with the corresponding floor response spectra of other Ukrainian NPPs and conclusions. The possibility for disseminating results obtained by the operating organization for ZNPP-3 to other units of the Ukrainian NPPs has been analyzed.
30 March 2020 in Journal of Mechanical Engineering