Jani Mäntyjärvi

Jani Mäntyjärvi

Auto-generated profile, based on publicly available information

Jani Mäntyjärvi

Sensing Solutions, VTT Technical Research Centre of Finland, Espoo, Finland

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2006 in IEEE Transactions on Information Technology in Biomedicine
Verified
Journal Article
Closed access
JPJ. Parkka
J. Parkka
MEM. Ermes
M. Ermes
PKP. Korpipaa
P. Korpipaa
JMJ. Mantyjarvi
J. Mantyjarvi
JPJ. Peltola
J. Peltola
IKI. Korhonen
I. Korhonen
Automatic classification of everyday activities can be used for promotion of health-enhancing physical activities and a healthier lifestyle. In this paper, methods used for classification of everyday activities like walking, running, and cycling are described. The aim of the study was to find out how to recognize activities, which sensors are useful and what kind of signal processing and classification is required. A large and realistic data library of sensor data was collected. Sixteen test persons took part in the data collection, resulting in approximately 31 h of annotated, 35-channel data recorded in an everyday environment. The test persons carried a set of wearable sensors while performing several activities during the 2-h measurement session. Classification results of three classifiers are shown: custom decision tree, automatically generated decision tree, and artificial neural network. The classification accuracies using leave-one-subject-out cross validation range from 58 to 97% for custom decision tree classifier, from 56 to 97% for automatically generated decision tree, and from 22 to 96% for artificial neural network. Total classification accuracy is 82% for custom decision tree classifier, 86% for automatically generated decision tree, and 82% for artificial neural network

7 January 2008 in IEEE Transactions on Information Technology in Biomedicine
Verified
Journal Article
Closed access
MEMiikka Ermes
Miikka Ermes
JPJuha Pärkkä
Juha Pärkkä
JMJani Mäntyjärvi
Jani Mäntyjärvi
IKIlkka Korhonen
Ilkka Korhonen
Physical activity has a positive impact on people's well-being, and it may also decrease the occurrence of chronic diseases. Activity recognition with wearable sensors can provide feedback to the user about his/her lifestyle regarding physical activity and sports, and thus, promote a more active lifestyle. So far, activity recognition has mostly been studied in supervised laboratory settings. The aim of this study was to examine how well the daily activities and sports performed by the subjects in unsupervised settings can be recognized compared to supervised settings. The activities were recognized by using a hybrid classifier combining a tree structure containing a priori knowledge and artificial neural networks, and also by using three reference classifiers. Activity data were collected for 68 h from 12 subjects, out of which the activity was supervised for 21 h and unsupervised for 47 h. Activities were recognized based on signal features from 3-D accelerometers on hip and wrist and GPS information. The activities included lying down, sitting and standing, walking, running, cycling with an exercise bike, rowing with a rowing machine, playing football, Nordic walking, and cycling with a regular bike. The total accuracy of the activity recognition using both supervised and unsupervised data was 89% that was only 1% unit lower than the accuracy of activity recognition using only supervised data. However, the accuracy decreased by 17% unit when only supervised data were used for training and only unsupervised data for validation, which emphasizes the need for out-of-laboratory data in the development of activity-recognition systems. The results support a vision of recognizing a wider spectrum, and more complex activities in real life settings.

11 October 2006
Verified
Conference Paper
Closed access
JMJ. Mantyjarvi
J. Mantyjarvi
MLM. Lindholm
M. Lindholm
EVE. Vildjiounaite
E. Vildjiounaite
SMS.-M. Makela
S.-M. Makela
HAHeikki Ailisto
Heikki Ailisto
Identifying users of portable devices from gait signals acquired with three-dimensional accelerometers was studied. Three approaches, correlation, frequency domain and data distribution statistics, were used. Test subjects (N=36) walked with fast, normal and slow walking speeds in enrolment and test sessions on separate days wearing the accelerometer device on their belt, at back. It was shown to be possible to identify users with this novel gait recognition method. Best equal error rate (EER=7%) was achieved with the signal correlation method, while the frequency domain method and two variations of the data distribution statistics method produced EER of 10%, 18% and 19%, respectively.

23 August 2005 in Personal and Ubiquitous Computing
Verified
Journal Article
Closed access
PDF file
JKJuha Kela
Juha Kela
PKPanu Korpipää
Panu Korpipää
JMJani Mäntyjärvi
Jani Mäntyjärvi
SKSanna Kallio
Sanna Kallio
GSGiuseppe Savino
Giuseppe Savino
SMSergio Di Marca
Sergio Di Marca

13 November 2002
Verified
Conference Paper
Closed access
JMJ. Mantyjarvi
J. Mantyjarvi
JHJ. Himberg
J. Himberg
TST. Seppanen
T. Seppanen

28 March 2005
Verified
Conference Paper
Closed access
PDF file
HAHeikki Ailisto
Heikki Ailisto
MLMikko Lindholm
Mikko Lindholm
JMJani Mantyjarvi
Jani Mantyjarvi
EVElena Vildjiounaite
Elena Vildjiounaite
SMSatu-Marja Makela
Satu-Marja Makela
Protecting portable devices is becoming more important, not only because of the value of the devices themselves, but for the value of the data in them and their capability for transactions, including m-commerce and m-banking. An unobtrusive and natural method for identifying the carrier of portable devices is presented. The method uses acceleration signals produced by sensors embedded in the portable device. When the user carries the device, the acceleration signal is compared with the stored template signal. The method consists of finding individual steps, normalizing and averaging them, aligning them with the template and computing cross-correlation, which is used as a measure of similarity. Equal Error Rate of 6.4% is achieved in tentative experiments with 36 test subjects.