Xiwen Shu

Xiwen Shu

Auto-generated profile, based on publicly available information

Xiwen Shu

Department of Radiation Oncology Duke University Durham North Carolina USA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2025 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
XSXiwen Shu
Xiwen Shu
KLKe Lu
Ke Lu
JZJingtong Zhao
Jingtong Zhao
JGJohn Ginn
John Ginn
YKYongbok Kim
Yongbok Kim
CWChunhao Wang
Chunhao Wang
Purpose: To develop a knowledge‐based deep model for sCT generation from a single MR volume in LINAC‐based frameless SRS, enabling the MR‐only workflow without extra CT simulation. Methods: A total of 139 patients were included in the study, with 120 used for training and 19 for testing. A Deep Residual U‐Net(DRU) was developed to generate sCT from patient‐specific high‐resolution T1 + Contrast MR volume, complemented by a healthy brain CT volume from the Visible Human Project that provides CT‐specific anatomical knowledge. To simulate treatment conditions, a template immobilization mask was deformed to align with the patient‐specific sCT anatomy, thereby creating a full sCT F volume. Four metrics, including PSNR, SSIM, RMSE, and MAE were derived to evaluate Hounsfield units(HU) accuracy of sCT compared to the ground‐truth CT without immobilization masks. Single isocenter multi‐target SRS plans developed with volumetric modulated arc therapy (VMAT) technique were recalculated within sCT F volumes to produce simulated dose distributions, which were compared with clinical plan dose distributions using the mean dose difference in the planning target volume(PTV) and gamma index evaluation. Results: In the test set, the generated sCT (statistics are reported as mean ± standard deviation) achieved a PSNR(Peak Signal‐to‐Noise Ratio) of 75 ± 4 dB, Structural Similarity Index (SSIM) of 0.99 ± 0.01, root mean square error (RMSE) of 11.9 ± 5.8 HU, and mean average error (MAE) of 1.4 ± 0.8 HU for brain tissues. When comparing sCT F dose calculation results against the original plans, gamma index passing rates were 95.8 ± 4.2% for the entire volume and 84.4 ± 15.0% within PTVs, using 3%/1 mm/15% threshold criteria. The median/ interquartile range of PTV dose differences were –2.0% and 2.3%, with all discrepancies below –5.0%. Conclusion: This study successfully demonstrated the generation and validation of sCT images from single‐modality MRI using a knowledge‐based deep model. The results confirm that single‐modality MRI without simulation CT scan effectively supports frameless SRS planning and integrates seamlessly into current clinical workflows.