Jinyang Huang

Jinyang Huang

Auto-generated profile, based on publicly available information

Jinyang Huang

School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2022 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
JHJinyang Huang
Jinyang Huang
YZYang Zhao
Yang Zhao
GXGuoming Xia
Guoming Xia
QSQin Shi
Qin Shi
AQAn Ping Qiu
An Ping Qiu
In this work, the processing error including the overetching error and residual stresses in the manufacturing process of a microelectromechanical system (MEMS) resonant accelerometer is identified. The performance of the accelerometer is affected by the processing error, especially the residual stress due to the multiple temperature loads in the manufacturing process. Thus, it is essential to identify the processing error for a high-precision MEMS resonant accelerometer. The overetching error is assessed using the sensitivity of the accelerometer resonator. With the multi-step measurement of the resonator frequency variation in the packaging process, the residual stresses of the MEMS accelerometer at different stages are decomposed and identified, combined with surface morphology measurement and finite element analysis simulations. The results of the analysis demonstrate that: 1) The processing error distribution of the accelerometer at the wafer level is related to the morphology of the wafer, which is decided by the low-order main vibrating modes. 2) The residual stress is distributed from high to low from the center to the edge in the wafer. 3) The residual stress at the wafer level is the main part of the MEMS accelerometer when low-stress packaging technology is adopted at the chip level. 4) The variation of the residual stresses in the manufacturing process is a non-monotonic process. The accurate identification of the processing error provides an effective foundation for the improvement and optimization of the MEMS resonant accelerometer. [2022-0041]

28 February 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JHJinyang Huang
Jinyang Huang
YZYang Zhao
Yang Zhao
GXGuo Ming Xia
Guo Ming Xia
QSQin Shi
Qin Shi
AQAn Ping Qiu
An Ping Qiu
Microelectromechanical system (MEMS)-based resonant accelerometers have great application potential in navigation guidance. In the present work, a systematic theoretical model of a MEMS resonant accelerometer was proposed. The coupling effect of microleverage mechanisms on the proof mass and the resonator was analyzed by the displacement coordination method for the first time. The resonant frequency of the proof mass, the natural frequency of the resonator, and the sensitivity of the accelerometer were united into one model for the structural cooperative design. The analytical model was approved by finite element simulations and verification experiments, and the relative error of key parameters was less than 13%. The analysis of the accelerometer architecture revealed that 1) joints between beams and the microleverage arm should be on the same level, 2) the geometric dimensions of the input beam and pivot beam of the microleverage should be the same, and 3) the microleverage arm width should be sufficient to ensure the rigidity. The performance of the accelerometer was also tested. The bias instability of $1 \mu \text{g}$ (Allan variance), the stability of $2.12 \mu \text{g}$ ( $1\sigma $ , 1 Hz date rate, one-hour length), and the nonlinearity of 16.3 ppm with the full range of ±20 g were achieved at room temperature.

7 August 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
GXGuoming Xia
Guoming Xia
YZYang Zhao
Yang Zhao
QSQin Shi
Qin Shi
JHJinyang Huang
Jinyang Huang
AQAn Ping Qiu
An Ping Qiu
Vibrating beam accelerometers (VBAs) have significant application potential in navigation guidance. This paper proposed a novel high-precision frequency readout method and integrated CMOS circuit implementation for VBAs. And technologies including sigma-delta modulation, up-sample and split, data synchronization and nonlinearity correction are employed in the method which is analyzed in detail in this paper. The method offers the advantages of low quantization noise, enough range, fixed output rate, and high linearity. Other force-frequency sensors could also benefit from this method but note that its noise suppression is most effective when the output rate is much smaller than the frequency under test. The method is implemented by a CMOS circuit and integrated with an oscillator circuit, which makes a full-function single-package VBA possible. Static, shock, random vibration, and centrifugal tests of the frequency readout circuit and VBA were performed. Test results show that the frequency quantization noise is less than 10 μHz/√Hz at 1 Hz, and can support 0.1 μg noise output. They also show that the vibration rectification error is lower than 0.5 mg at 8 grms, and that the 20 g full range nonlinearity is 16 ppm.

21 April 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MXMeijia Xu
Meijia Xu
QSQin Shi
Qin Shi
JHJinyang Huang
Jinyang Huang
YZYang Zhao
Yang Zhao
GXGuoming Xia
Guoming Xia
AQAn Ping Qiu
An Ping Qiu
For high-accurate micro-electro-mechanical systems (MEMS) gyroscopes, comb gap errors influence the mechanical coupling errors and limit performance. In this study, an in situ method was proposed to identify the gaps of drive combs, drive-sense combs, and sense combs in MEMS gyroscopes that can be applied at the wafer level. Negative electrostatic stiffness of combs was considered in the model construction of the sense mode and the Y-axis in-phase mode, and the frequency change caused by this was applied to characterize the comb gaps. Eight chips in different positions of a wafer were selected for verification of this method. The results shows that errors of drive comb gaps, drive-sense comb gaps, and sense comb gaps in the chip near the wafer center were 0.67 μm, 0.60 μm, and 0.53 μm, respectively, and those in the chip at the wafer edge were 0.96 μm, 0.95 μm, and 0.71 μm, respectively. The variation of comb gaps was 0.08 μm in a single chip near the wafer center, and 0.03 μm in a single chip at the wafer edge. This work provides a method for the fabless designers to explore the effect of wafer process on the structures and reduce it through careful design.

27 April 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YZYang Zhao
Yang Zhao
QSQin Shi
Qin Shi
GXGuoming Xia
Guoming Xia
JHJinyang Huang
Jinyang Huang
AQAn Ping Qiu
An Ping Qiu
This paper proposes an Active Probe Card (APC) equipment for MEMS gyroscopes offering multi-parameter that address the concerns of manufacturers and end-users. An efficient and reliable frequency and Q-factor (f&Q) measurement method, enabled by a negative impedance converter (NIC), is firstly applied to the one-port sense resonator of the gyroscope. While the gyroscope’s drive loop oscillates continuously, the f&Q measurement periods for drive/sense resonators and the fully operational gyroscope characterization periods are merged. It eliminates the time overhead associated with high-Q mode ring-down, restart-up waiting, and connection reconfiguration. Furthermore, the system incorporates a variable polarization voltage (Vp) function. The true process related monitoring parameters and predictions of gyroscope operating behaviors with specific frequency split (Δf) are automatically extracted from two sequential tests with different Vp loads. The time cost per DUT is <5s. The probes carrier card and active electronics card are interconnected with pluggable shielded cables, facilitating easy upgrading and adaptation to gyroscopes with different pin definitions. Using the proposed APC equipment, we demonstrate it can 1) realize the extraction and monitoring of true dimension and encapsulated pressure parameters in both the same and different process stages;2) perform system-level gyroscope operating behaviors pre-validation and grading at the wafer level.

24 February 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YZYang Zhao
Yang Zhao
GXGuoming Xia
Guoming Xia
JHJinyang Huang
Jinyang Huang
QSQin Shi
Qin Shi
AQAn Ping Qiu
An Ping Qiu
Electrical interconnect loss degrades the intrinsic high Q-factor of MEMS gyroscopic resonators and alters their phase response. This paper proposes, for the first time, a loss cancellation approach utilizing an in-situ integrated negative impedance converter (NIC), which requires no additional tuning structures or electrodes. Controllable positive feedback is embedded into the conventional transimpedance amplifier (TIA), yielding a virtual negative resistance (NR) that cancels the interconnect loss or even the intrinsic loss of the resonator itself. We further demonstrate that through proper zero-pole arrangement of the Opam and its feedback network, the NIC can be degenerated into a single-pole system, thereby eliminating stability risk. Serving as the front-end of a split-mode MEMS gyroscope, this scheme recovers the sense Q-factor from a damped value of 2.8k to its intrinsic value of 42k and passively reduces its thermal variation from 52% to 2.1%. Furthermore, it corrects the gyrof’s phase shift from 1.25deg to 0.06deg, corresponding to a reduction in the quadrature leakage coefficient from 2.2% to 0.1% and maintaining a variation of 40ppm over a 100°C-temperature range, even without the use of a high-accurate active stabilization loop.