Lu Jin

Lu Jin

Auto-generated profile, based on publicly available information

Lu Jin

Yiwu Research Institute of Fudan University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2019 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
LJLu Jin
Lu Jin
YZYan Zheng
Yan Zheng
ZLZekun Liu
Zekun Liu
Jiashen LiJiashen Li
Jiashen Li
HZHeng Zhai
Heng Zhai
YLYi Li
Yi Li

17 August 2022 in npj Flexible Electronics
Verified
Journal Article
Open access
PDF file
LJLu Jin
Lu Jin
ZLZhenhong Li
Zhenhong Li
ZLZekun Liu
Zekun Liu
BRBethany Richardson
Bethany Richardson
YZYan Zheng
Yan Zheng
YLYi Li
Yi Li
Multiple strain sensors are required to identify individual forces/stresses on human joints and recognize how they work together in order to determine the motion’s direction and trajectory. However, current sensors cannot detect and differentiate the individual forces/stresses and their contributions to the motion from the sensors’ electrical signals. To address this critical issue, we propose a concept of unimodal tension, bend, shear, and twist strain sensors with piezoelectric poly L-lactic acid films. We then construct an integrated unimodal sensor (i-US) using the unimodal sensors and prove that the i-US can detect and differentiate individual strain modes, such as tensioning, bending, shearing, and twisting in complex motion. To demonstrate the potential impact of unimodal sensors, we design a sleeve and a glove with the i-US that can capture wrist motions and finger movements. Therefore, we expect unimodal strain sensors to provide a turning point in developing motion recognition and control systems.

22 July 2022 in ACS Sensors
Verified
Journal Article
Open access
LJLu Jin
Lu Jin
ZLZekun Liu
Zekun Liu
MAMucahit Altintas
Mucahit Altintas
YZYan Zheng
Yan Zheng
ZLZhangchi Liu
Zhangchi Liu
YLYi Li
Yi Li
Despite the importance of respiration and metabolism measurement in daily life, they are not widely available to ordinary people because of sophisticated and expensive equipment. Here, we first report a straightforward and economical approach to monitoring respiratory function and metabolic rate using a wearable piezoelectric airflow transducer (WPAT). A self-shielded bend sensor is designed by sticking two uniaxially drawn piezoelectric poly l-lactic acid films with different cutting angles, and then the bend sensor is mounted on one end of a plastic tube to engineer the WPAT. The airflow sensing principle of the WPAT is theoretically determined through finite element simulation, and the WPAT is calibrated with a pulse calibration method. We prove that the WPAT has similar accuracy (correlation coefficient >0.99) to a pneumotachometer in respiratory flow and lung volume assessment. We demonstrate metabolism measurement using the WPAT and the relationship between minute volume and metabolic rates via human wear trials. The mean difference of measured metabolic rates between the WPAT and a Biopac indirect calorimeter is 0.015 kcal/min, which shows comparable performance. Significantly, unlike the Biopac indirect calorimeter with an airflow sensor, an oxygen gas sensor, and a carbon dioxide gas sensor, we merely use the simple-structured WPAT to measure metabolism. Thus, we expect the WPAT technology to provide a precise, convenient, and cost-effective respiratory and metabolic monitoring solution for next-generation medical home care applications and wearable healthcare systems.

26 May 2018 in Fire Technology
Verified
Journal Article
Open access
PDF file
LJLu Jin
Lu Jin
MCMing Liang Cao
Ming Liang Cao
WYWinnie Yu
Winnie Yu
JHJun Yan Hu
Jun Yan Hu
KYKee Jong Yoon
Kee Jong Yoon
YLYi Li
Yi Li
This paper presents new proposals in the evaluation and determination of the optimum materials suitable for use in the design and development of firefighter protective clothing by simultaneously addressing the conflicting factors of thermal protection [heat transfer index (HTI), radiant heat transfer index (RHTI) and thermal threshold index (TTI)] and anti-heat stress [water vapor resistance (WVR) and total heat loss (THL)]. To achieve this, this paper proposes new indices for the materials, two types of “total performance” indices, which are defined as the sum and the product of the competing factors of thermal protection and anti-heat stress. The results showed that the candidate materials of firefighter protective clothing were easily rated when the new indices were applied. Of five candidate materials viz. A, B, B1, B2 and C, the B sample, with values for HTI24 = 13.2 ± 0.2 s, RHTI24 = 18.0 ± 0.8 s, TTI = 1132 ± 33 J/m2, WVR = 17.5 ± 0.3 m2 Pa/W and THL = 266.2 ± 4.1 W/m2, was found to exhibit the best total performance. However, the methods proposed to the scientific community in this paper have so far been validated on a limited data set only, and will require further validation by a wider group of researchers and with more samples. Lastly, comments on ISO 11999-3:2015 were also made for the further improvement and development of technical standards.

24 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MRMohammad Shamim Reza
Mohammad Shamim Reza
LJLu Jin
Lu Jin
YJYou Jeong Jeong
You Jeong Jeong
Tong In OhTong In Oh
Tong In Oh
HKHongdoo Kim
Hongdoo Kim
KKKap Jin Kim
Kap Jin Kim
This study aims to find base materials for dry electrode fabrication with high accuracy and without reducing electrode performance for long-term bioelectric potential monitoring after electroless silver plating. Most applications of dry electrodes that have been developed in the past few decades are restricted by low accuracy compared to commercial Ag/AgCl gel electrodes, as in our previous study of PVDF-based dry electrodes. In a recent study, however, nanoweb-based chlorinated polyisoprene (CPI) and poly(styrene-b-butadiene-b-styrene) (SBS) rubber were selected as promising candidates due to their excellent elastic properties, as well as their nanofibril nature, which may improve electrode durability and skin contact. The electroless silver plating technique was employed to coat the nanofiber web with silver, and silver nanoweb(AgNW)-based dry electrodes were fabricated. The key electrode properties (contact impedance, step response, and noise characteristics) for AgNW dry electrodes were investigated thoroughly using agar phantoms. The dry electrodes were subsequently tested on human subjects to establish their realistic performance in terms of ECG, EMG monitoring, and electrical impedance tomography (EIT) measurements. The experimental results demonstrated that the AgNW dry electrodes, particularly the SBS-AgNW dry electrodes, performed similarly to commercial Ag/AgCl gel electrodes and were outperformed in terms of long-term stability.

2 October 2024 in ACS Sensors
Verified
Journal Article
Closed access
LJLu Jin
Lu Jin
JLJiahao Li
Jiahao Li
YYYifan Yang
Yifan Yang
YMYongfeng Mei
Yongfeng Mei
Enming SongEnming Song
Enming Song