Currently, various materials are routinely used for cranioplasty after decompressive craniectomy, each with their own features, potential benefits, and harms. To systematically review available literature about safety (infection, resorption, and removal) of different materials used for cranioplasty for any indication. A comprehensive search in MEDLINE, EMBASE, and the Cochrane library was performed for relevant studies published up to January 2017. Study quality was assessed according to the Cochrane Collaboration risk of bias assessment tool, and a set of 27 predetermined parameters was extracted by 2 investigators independently for further analysis. The search yielded 2 randomized, 14 prospective, and 212 retrospective studies, totaling 10,346 cranioplasties in which 1952 (18.9%) complications were reported in patients between 0 and 90 years old. Overall, study quality was low and heterogeneity was large. Graft infections and resorption were most prevalent: overall infection rate was 5.6%. Autologous cranioplasties showed an infection rate of 6.9% versus 5.0% in combined alloplastic materials, including poly(methyl methacrylate) with 7.8%. Resorption occurred almost exclusively in autologous cranioplasties (11.3%). The greatest removal rate was reported for autologous cranioplasties (overall: 10.4%), which was significantly greater than that of combined alloplastic materials (overall: 5.1%; risk difference = 0.052 [95% confidence interval: 0.039-0.066]; NNT = 19 [95% confidence interval: 15-25]). Available evidence on the safety of cranioplasty materials is limited due to a large diversity in study conduct, patients included, and outcomes reported. Autografts appear to carry a greater failure risk than allografts. Future publications concerning cranioplasties will benefit by a standardized reporting of surgical procedures, outcomes, and graft materials used.
10 November 2006 in Clinical Oral Implants Research
Gastric tube reconstruction (GTR) is a high-risk surgical procedure with substantial perioperative morbidity. Compromised arterial blood supply and venous congestion are believed to be the main etiologic factors associated with early and late anastomotic complications. Identifying low blood perfusion areas may provide information on the risks of future anastomotic leakage and could be essential for improving surgical techniques. The aim of this study was to generate a method for gastric microvascular perfusion analysis using laser speckle contrast imaging (LSCI) and to test the hypothesis that LSCI is able to identify ischemic regions on GTRs.Patients requiring elective laparoscopy-assisted GTR participated in this single-center observational investigation. A method for intraoperative evaluation of blood perfusion and postoperative analysis was generated and validated for reproducibility. Laser speckle measurements were performed at 3 different time pointes, baseline (devascularized) stomach (T0), after GTR (T1), and GTR at 20° reverse Trendelenburg (T2).Blood perfusion analysis inter-rater reliability was high, with intraclass correlation coefficients for each time point approximating 1 (P < 0.0001). Baseline (T0) and GTR (T1) mean blood perfusion profiles were highest at the base of the stomach and then progressively declined towards significant ischemia at the most cranial point or anastomotic tip (P < 0.01). After GTR, a statistically significant improvement in mean blood perfusion was observed in the cranial gastric regions of interest (P < 0.05). A generalized significant decrease in mean blood perfusion was observed across all GTR regions of interest during 20° reverse Trendelenburg (P < 0.05).It was feasible to implement LSCI intraoperatively to produce blood perfusion assessments on intact and reconstructed whole stomachs. The analytical design presented in this study resulted in good reproducibility of gastric perfusion measurements between different investigators. LSCI provides spatial and temporal information on the location of adequate tissue perfusion and may thus be an important aid in optimizing surgical and anesthesiological procedures for strategically selecting anastomotic site in patients undergoing esophagectomy with GTR.
Purpose To test the hypothesis that the sensitivity of near-infrared spectroscopy (NIRS) in reflecting the degree of (compensated) hypovolemia would be affected by the application site and probing depth. We simultaneously applied multi-site (thenar and forearm) and multi-depth (15–2.5 and 25–2.5 mm probe distance) NIRS in a model of simulated hypovolemia: lower body negative pressure (LBNP). Methods The study group comprised 24 healthy male volunteers who were subjected to an LBNP protocol in which a baseline period of 30 min was followed by a step-wise manipulation of negative pressure in the following steps: 0, −20, −40, −60, −80 and −100 mmHg. Stroke volume and heart rate were measured using volume-clamp finger plethysmography. Two multi-depth NIRS devices were used to measure tissue oxygen saturation (StO2) and tissue hemoglobin index (THI) continuously in the thenar and the forearm. To monitor the shift of blood volume towards the lower extremities, calf THI was measured by single-depth NIRS. Results The main findings were that the application of LBNP resulted in a significant reduction in stroke volume which was accompanied by a reduction in forearm StO2 and THI. Conclusions NIRS can be used to detect changes in StO2 and THI consequent upon central hypovolemia. Forearm NIRS measurements reflect hypovolemia more sensitively than thenar NIRS measurements. The sensitivity of these NIRS measurements does not depend on NIRS probing depth. The LBNP-induced shift in blood volume is reflected by a decreased THI in the forearm and an increased THI in the calf.