1 January 2015 in Mathematical Problems in Engineering
Nowadays, the increasing demand for telemedicine services has raised interest in the real-time medical image protection literatures. In this paper, we evaluate the security of an efficient and secure medical image protection scheme recently proposed (Fu et al., 2013). It is found that this scheme can be successfully broken by launching chosen-plaintext attacks. Improvement is subsequently developed for promoting the security and efficiency performance. Extensive security analyses and experimental results both indicate that the improved scheme can well address the security flaws and advance the speed performance of the original one.
13 October 2023 in European Journal of Medical Research
Background and purpose: Malignant brain edema (MBE) occurring after mechanical thrombectomy (MT) in acute ischemic stroke (AIS) could lead to severe disability and mortality. We aimed to investigate the incidence, predictors, and clinical outcomes of MBE in patients with AIS after MT. Methods: The clinical and imaging data of 155 patients with AIS of anterior circulation after MT were studied. Standard non-contrast CT was used to evaluate baseline imaging characteristics at admission. Clinical outcomes were measured using the 90-day modified Rankin Scale (mRS) score. Based on the follow-up CT scans performed within 72 h after MT, the patients were classified into MBE and non-MBE group. MBE was defined as a midline shift of ≥ 5 mm with signs of local brain swelling. Univariate and multivariate regression analyses were used to analyze the relationship between MBE and clinical outcomes and identify the predictors that correlate with MBE. Results: MBE was observed in 19.4% of the patients who underwent MT and was associated with a lower rate of favorable 90-day clinical outcomes. Significant differences were observed in both MBE and non-MBE groups: baseline Alberta Stroke Program Early CT (ASPECT) score, hyperdense middle cerebral artery sign (HMCAS), baseline signs of early infarct, angiographic favorable collaterals, number of retrieval attempts, and revascularization rate. Multivariate analysis indicated that low baseline ASPECT score, absent HMCAS, angiographic poor collaterals, more retrieval attempt count, and poor revascularization independently influenced the occurrence of MBE in AIS patients with anterior circulation after MT. Conclusion: MBE was associated with a lower rate of favorable 90-day clinical outcomes. Low baseline ASPECT score, absent HMCAS, angiographic poor collaterals, more retrieval attempt count and poor revascularization were independently associated with MBE after MT.
1 January 2015 in Mathematical Problems in Engineering
This paper presents a solution to satisfy the increasing requirements for secure medical image transmission and storage over public networks. The proposed scheme can simultaneously encrypt and compress the medical image using compressive sensing (CS) and pixel swapping based permutation approach. In the CS phase, the plain image is compressed and encrypted by chaos-based Bernoulli measurement matrix, which is generated under the control of the introduced Chebyshev map. The quantized measurements are then encrypted by permutation-diffusion type chaotic cipher for the second level protection. Simulations and extensive security analyses have been performed. The results demonstrate that at a large scale of compression ratio the proposed cryptosystem can provide satisfactory security level and reconstruction quality.