Michael Bartellas

Michael Bartellas

Auto-generated profile, based on publicly available information

Michael Bartellas

NYU Langone Medical Center, New York, United States

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2017 in Cureus
Verified
Journal Article
Open access
GDGregory Doucet
Gregory Doucet
SRStephen Ryan
Stephen Ryan
MBMichael Bartellas
Michael Bartellas
MPMichael Parsons
Michael Parsons
ADAdam Dubrowski
Adam Dubrowski
TRTia Renouf
Tia Renouf
Cricothyroidotomy is a life-saving medical procedure that allows for tracheal intubation. Most current cricothyroidotomy simulation models are either expensive or not anatomically accurate and provide the learner with an unrealistic simulation experience. The goal of this project is to improve current simulation techniques by utilizing rapid prototyping using 3D printing technology and expert opinions to develop inexpensive and anatomically accurate trachea simulators. In doing so, emergency cricothyroidotomy simulation can be made accessible, accurate, cost-effective and reproducible. Three-dimensional modelling software was used in conjunction with a desktop three-dimensional (3D) printer to design and manufacture an anatomically accurate model of the cartilage within the trachea (thyroid cartilage, cricoid cartilage, and the tracheal rings). The initial design was based on dimensions found in studies of tracheal anatomical configuration. This ensured that the landmarking necessary for emergency cricothyroidotomies was designed appropriately. Several revisions of the original model were made based on informal opinion from medical professionals to establish appropriate anatomical accuracy of the model for use in rural/remote cricothyroidotomy simulation. Using an entry-level desktop 3D printer, a low cost tracheal model was successfully designed that can be printed in less than three hours for only $1.70 Canadian dollars (CAD). Due to its anatomical accuracy, flexibility and durability, this model is great for use in emergency medicine simulation training. Additionally, the model can be assembled in conjunction with a membrane to simulate tracheal ligaments. Skin has been simulated as well to enhance the realism of the model. The result is an accurate simulation that will provide users with an anatomically correct model to practice important skills used in emergency airway surgery, specifically landmarking, incision and intubation. This design is a novel and easy to manufacture and reproduce, high fidelity trachea model that can be used by educators with limited resources.

18 January 2024 in The Laryngoscope
Verified
Journal Article
Closed access
EREmma De Ravin
Emma De Ravin
AQAlexandra E. Quimby
Alexandra E. Quimby
MBMichael Bartellas
Michael Bartellas
SSSydnie Swanson
Sydnie Swanson
THTiffany P. Hwa
Tiffany P. Hwa
MRMichael J. Ruckenstein
Michael J. Ruckenstein

7 April 2026 in Journal of Neurological Surgery Reports
Verified
Journal Article
Open access
PDF file
JCJustin Cottrell
Justin Cottrell
MBMichael Bartellas
Michael Bartellas
SMSean McMenomey
Sean McMenomey
JGJohn G. Golfinos
John G. Golfinos
JRJ. Thomas Roland
J. Thomas Roland
Objective To demonstrate magnetic resonance imaging’s (MRI’s) utility in investigating auditory brainstem implant (ABI) performance degradation. Design Case study. Setting Academic medical center. Participant This report presents a patient with neurofibromatosis type 2 and an ABI with durable, limited open-set speech who developed nonauditory side effects and a complete lack of auditory perception. ABI paddle placement was assessed with 1.5 Tesla (T) Siemens MRI, and device function was assessed utilizing integrity tests. Main Outcome Measure The etiology of ABI performance degradation utilizing 1.5 T Siemens MRI. Results On initial postoperative 1.5 T Siemens MRI, the ABI paddle approximated the cochlear nucleus. Approximately 1 year later, the patient experienced ABI performance degradation and dizziness. Although ABI device integrity testing was normal, follow-up 1.5 T Siemens MRI revealed lateral ABI paddle migration from the foramen of Luschka toward the flocculus, likely due to observed fat atrophy from the prior craniotomy reconstruction, suggesting a possible etiology for the observed ABI degradation. Conclusion This report presents MRI’s ability to successfully delineate postoperative fat atrophy, ABI paddle migration in relation to the brainstem, and residual tumor in a patient with ABI degradation.